Browse > Article

Influence of the Inclination Angle and Liquid Charge Ratio on the Condensation in Closed Two-Phase Thermosyphons with Axial Internal Low-Fins  

Cho, Dong-Hyun (Department of Mechanical Engineering, Daejin University)
Han, Kyu-il (Department of Control and Mechanical Design Engineering, National Pukyong University)
Publication Information
Journal of Mechanical Science and Technology / v.17, no.3, 2003 , pp. 422-428 More about this Journal
Abstract
This study concerns the performance of the heat transfer of the thermosyphons having 60, 70, 80. 90 axial internal low-fins in which boiling and condensation occurr. Water, HCFC-141b and CFC-11 have been used as the working fluids. The operating temperature, the liquid charge ratio and the inclination angle of thermosyphons have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation, it was found that the maximum heat flow rate in the thermosyphons is dependent upon the liquid charge ratio and inclination angle. A relatively high rate of heat transfer has been achieved by the thermosyphon with axial internal low-fins. The inclination of a thermosyphon has a notable influence on the condensation. In addition, the overall heat transfer coefficients and the characteristics at the operating temperature are obtained for the practical applications.
Keywords
Condensation; Inclination Angle; Liquid Charge Ratio; Heat Transfer Coefficient; Thermosyphon;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Cohen, H., Baylay, F. J., 1955, 'Heat Transfer Problems of Liquid Cooled Gas Turbine Blades,' Proc. Inst. Mech. Eng., 169, 1063-1080   DOI
2 Hahne, E. and Gross, U., 'The Influence of the Inclination Angle on the Performance of a Closed Two-Phase Thermosyphon,' 4th IHPC, London
3 Kim, W. T., Song, K. S. and Lee, Y., 1998, 'Design of a Two-Phase Loop Thermosyphon for Telecommunication System (II)-Experimentals and Visualization-,' KSME Int. J., Vol. 12, No. 5, pp. 942-955
4 Lee, B. I., Lee, S. H., 2001, 'Manufacturing and Temperature Measurements of a Sodium Heat Pipe,' KSME Int. J., Vol. 15, No. 11, pp. 1533-1540   과학기술학회마을
5 Nusselt, W., 1916, 'Die Ooberflachen-Kondensation des Waserdampfes,' Zeitschr. V.D.I., Vol. 60, pp. 541-569
6 Negishi, K. and Sawada, T., 'Heat Transfer Performance of an Inclined Two-Phase Closed Thermosyphon,' Int. J. Heat Mass Transfer, 26, No. 8, pp. 1207-1213   DOI   ScienceOn
7 Nguyen-Chi, H. and Groll, M., 1981, 'Entrainment of flooding Limit in a Closed Two-Phase Thermosyphon,' 4th IHPC, Tsukuba, 1-6
8 Kim, W. T., Song, K. S. and Lee, Y., 1998, 'Design of a Two-Phase Loop Thermosyphon for Telecommunication System (I)-Experimentals and Visualization-,' KSME Int. J., Vol. 12, No. 5, pp. 926-941   DOI
9 Tu, C., Xie, G., Hu, C., Gao, Z. and Hong, R., 1984, 'The two Phase Closed Thermosyphon : an Experimental Study with flow Pattern and Optimum Fill Charge,' China-U.S. Seminar on Two-flows and Heat Transfer, Sian, pp. 395-405
10 Lee, Y. and Mital, U., 1972, 'A Two-Phase Closed Thermosyphon,' Int. J. Heat and Mass Transfer, 15, pp. 1695-1707   DOI   ScienceOn
11 Yiwei, M., Wang, J. C. Y., Jifu, L. and Yi, F., 1989, 'Theoretical and Experimental Studies on Condensation Heat Transfer inside Vertical and Inclined Thermosyphons,' National Heat Transfer Conference HTD-Vol. 108, pp. 111-116
12 Noie, S. H., Kalaei, M. H., Sanati, R. and Mohammad-Taheri, M., 2002, Thermal Characteristics of a Two-Phase Closed Thermosyphon, 12th IHPC, Vol. 2, D-5
13 Rhi, S. H., Kim, W. T. and Lee, Y., 1997, 'A Cooling System Using Wickless Heat Pipes for Multichip Modules : Experiment and Analysis,' KSME Int. J., Vol. 11, No. 2, pp. 208-220   DOI