Abstract
A simple finite element analysis is performed to simulate the thermal characteristics of a micro sensor package with thin film heater embedded in the glass wall of a micro-channel. In this paper, Electric characteristics of ITO sputtered heater were presented in this study, which can be used as a map of heater design in the range of available system temperature. The effects of thermo-physical properties of materials, geometrical structure and boundary condition on the thermal performance are also investigated. Finally, the design of micro-flow induced thermal sensor that is capable of measuring fluid flow with a lower flow detection limit of approximately 24pL/s is presented.
Keywords
microchannel; microheating; ITO; sputtered heater; PDMS;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lammerink, T. S. J., Tas, N. R., Elwenspoek, M., Fluitman, J. H. J., 'Micro-liquid flow sensor,' Sensors and Actuators A, 37-38, pp.45-50, 1993   DOI
2 A. M. Christensen, D. A. Chang-Yen, B. K. Gale, 'Characterization of interconnects used in PDMS microfluidic systems,' J. Micromech. Microeng. 15, pp. 928-934, 2005   DOI   ScienceOn
3 Gaitan, M., Locascio, L. E., 'Embedded Micro-Heating Elements in Polymeric Micro-Channels for Temperature Control and Fluid Flow Sensing,' J. Res. Natl. Inst. Stand. Technol. 109, pp. 335344,2004   DOI   ScienceOn
4 Lin, Y. C., Yang, C. C, Huang, M. Y., 'Simulation and experimental validation of micro polymerase chain reaction chips,' Sensors And Actuators B 71, pp. 127-133,2000
5 Zou, Z. Q., Chen, X, Jin, Q. H., Yang, M. S., Zhao, J. L., 'A novel miniaturized PCR multi-reactor array fabricated using flipchip bonding techniques,' J. Micromech. Microeng. 15, pp. 1476-1481,2005   DOI   ScienceOn
6 COMSOL Multi-physics 3.2 user's guide 2005
7 Elwenspoek, M., Wiegerink, R., 'Mechanical Microsensors,' Springer
8 Nguyen, N. T., Wereley, S. T., 'Fundamentals and Applications of Microfluidics,' Artech House, INC., 2002
9 Narshimha Rao, K., 'Preparation of transparent conductive oxide films by activated reactive evaporation,' OPT. Eng. 41 (11), pp. 2705-2706., 2002   DOI   ScienceOn
10 DeVeo, D. L., 'Thermal Issues in MEMS and Microscale Systems,' IEEE Transactions On Components And Packaging Technologies, Vol. 25, No.4, pp. 576-583, 2003   DOI   ScienceOn
11 Edwards, T. L., Gale, B. K., Frazier, A. B., 'A Micromachined Therrnal Field-Flow Fractionation System,' in Proc. of Transducers '99, pp. 742-745, 1998
12 Kersjes, R., Liebscher, E, Spiegel, E., Manoli, Y., Mokwa, W., 'An invasive catheter flow sensor with on-chip CMOS readout electronics for the on-line determination of blood flow,' Sensors and Actuators A 54, pp. 563-567, 1996
13 Qiu, L., Hein, S., Obermeier, E., Schubert, A., 'Micro gas-flow sensor with integrated heat sink and flow guide,' Sensors and Actuators A 54, pp. 547-551, 1996
14 van der Wiel, A. J., Linder, C., de Rooij, N. E, Bezinge, A., 'A liquid velocity sensor based on the hot-wire principle,' Sensors and Actuators A, 37-38, pp. 693-697, 1993   DOI
15 Yang, M., Pal, R., Burns, M. A., 'Cost-effective thermal isolation techniques for use on microfabricated DNA amplification and analysis devices,' J. Micromech. Microeng. 15, pp. 221-230, 2005   DOI   ScienceOn