Browse > Article

Measurement and Prediction of the Flash Points for Flammable Liquid Mixtures with Non-flammable Component  

Ha, Dong-Myeong (Department of Occupational Health and Safety Engineering, Semyung University)
Yu, Hyun-Sik (Department of Occupational Health and Safety Engineering, Semyung University)
Kang, Gyeun-Hee (Department of Occupational Health and Safety Engineering, Semyung University)
Ann, Jeong-Jin (Korea Gas Safety Corporation)
Lee, Sung-Jin (Department of Clinical Laboratory Science, Semyung University)
Publication Information
International Journal of Safety / v.7, no.2, 2008 , pp. 12-16 More about this Journal
Abstract
Lower flash points for the binary systems, carbon tetrachloride+o-xylene and water+n-butanol were measured by Pensky-Martens closed cup tester. The Raoult's law and optimization method using van Laar equation were used to predict the lower flash points and were compared with experimental data. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.
Keywords
flash point; pensky-martens closed cup apparatus; raoult's law; van laar equation; optimization method;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 V. Babrauskas, "Ignition Handbook", Fire Science Publishers, SFPE, 2003
2 D.M. Ha and S.J. Lee, "The Measurement and Estimation of Lower Flash Points for n-Propanol+Acetic acid and n-Propanol+n-Propionic acid Systems", Journal of the Korean Society of Safety, Vol. 22, No. 4, pp. 38-42, 2007   과학기술학회마을
3 D.M. Ha, Y.C Choi and S.J. Lee, "Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus", Journal of the Korean Society of Safety, Vol. 17, No. 4, pp. 140-145, 2002
4 J.L. Kuester and J.H. Mize, "Optimization Techniques with Fortran", McGraw-Hill, New York, 1973
5 ASTM, "Standard Test Method for Flash-Point by Pensky-Martens Closed Cup Tester(ASTM D93)", American Society for Testing Materials, Philadelpia, PA, 1994
6 B.F. Hanley, "A Model for the Calculation and the Verification of Closed Cup Points Multicomponent Mixtures", Process Safety Progress, Vol. 17, No.2, pp.86-97, 1998   DOI   ScienceOn
7 D.M. Ha and S.J. Lee, "The Measurement and Prediction of the Flash Points for Water+2-Propanol System Using Open-Cup Apparatus", J. of Korean Institute of Fire Sci. & Eng., Vol. 21, No. 2, pp. 48-53, 2007   과학기술학회마을
8 J.C. Park, D.M. Ha and M.G. Kim, "Modified Response Surface Methodology (MRSM) for Phase Equilibrium-Theoretical Background", Korean J. of Chemical Engineering, Vol. 13, pp. 115-122, 1996   DOI
9 J.M. Smith and H.C. Van Ness, "Introduction to Chemical Engineering Thermodynamics", 4nd ed., McGraw-Hill, 1987
10 D.M. Ha, S.J. Lee and M.H. Back, "Measurement and Estimation of the Lower Flash Points for the Flammable Binary Systems Using a Tag Open Cup Tester", Korean J. of Chemical Engineering, Vol. 24, No. 4, pp. 551-555, 2007   DOI
11 D.A. Crowl and J.F. Louvar, "Chemical Process Safety: Fundamentals with Applications", Englewood Cliffs, New York, Prentice-Hall, 1990
12 C.R. Reid, J.M. Prausnitz and B.E. Poling, "The Properties of Gases and Liquids", 4nd ed., McGraw-Hill, New York, 1998