1 |
N. G. Hingorani and L. Gyugyi, Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems. Piscataway, NJ: IEEE Press, 2000.
|
2 |
M. S. El-Moursi, and A. M. Sharaf, “Novel controllers for the 48-pulse VSC STATCOM and SSSC for voltage regulation and reactive power compensation,” IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1985-1997, Nov. 2005.
DOI
ScienceOn
|
3 |
F. A. Albasri, T. S. Sidhu, and R. K. Varma, “Performance comparison of distance protection schemes for shunt-FACTS compensated transmission lines,” IEEE Trans. Power Del., vol. 22, no. 4, pp. 2116-2125, Oct. 2007.
DOI
|
4 |
M. Khederzadeh, and A. Ghorbani, “STATCOM modeling impacts on performance evaluation of distance protection of transmission lines,” European Transaction on Electrical Power., vol. 21, no. 8, pp. 2063-2079, Nov. 2011.
DOI
ScienceOn
|
5 |
W-H. Zhang, S-J. Lee, and M-S. Choi, “Setting considerations of distance relay for transmission line with STATCOM,” Journal of Electrical Engineering & Technology., vol. 5, no. 4, pp. 522-529, 2010.
DOI
ScienceOn
|
6 |
A. P. de Morais, G. Cardoso, and L. Mariotto, “An innovative loss-of-excitation protection based on the fuzzy inference mechanism,” IEEE Trans. Power Del., vol. 5, no. 4, pp. 2197-2204, Oct. 2010.
|
7 |
X. Zhou, H. Wang, R. K. Aggarwal, and P. Beaumont, “Performance evaluation of a distance relay as applied to a transmission system with UPFC,” IEEE Trans. Power Del., vol. 21, no. 3, pp. 1137-1147, Jul. 2006.
DOI
ScienceOn
|
8 |
M. Khederzadeh and A. Ghorbani, “Impact of VSC-based multiline FACTS controllers on distance protection of transmission lines,” IEEE Trans. Power Del., vol. 27, no. 1, pp. 32-39, Jan. 2012.
DOI
ScienceOn
|
9 |
S. R. Samantaray, “A data-mining model for protection of FACTS-based transmission line,” IEEE Trans. Power Del., vol. 28, no. 2, pp. 612-618, Apr. 2013.
DOI
ScienceOn
|
10 |
J. Berdy, “Loss of excitation protection for modern synchronous generators,” IEEE Trans. Power App. Syst., vol. PAS-94, no. 5, pp. 1457-1463, Sep./Oct. 1975.
|
11 |
A. Ghorbani, and Others, “Operation of synchronous generator LOE protection in the presence of shunt-FACTS,” Electric Power Systems Research., vol. 119, pp. 178-186, Feb. 2015.
DOI
ScienceOn
|
12 |
A. Ghorbani, B. Mozafari, and A.M. Ranjbar, “Digital distance protection of transmission lines in the presence of SSSC,” International Journal of Electrical Power and Energy Systems., vol. 43, no. 1, pp. 712-719, Dec. 2012.
DOI
ScienceOn
|
13 |
P. Kundur, Power System Stability and Control. New York: Mc-Grow-Hill, 1994.
|
14 |
M. Khederzadeh, and T. Sidhu, “Impact of TCSC on the protection of transmission lines,” IEEE Trans. Power Del., vol. 21, no. 1, pp. 80-87, Jan. 2006.
DOI
ScienceOn
|
15 |
L. Shenghu, “Power flow control effect with TCSC on operation margin of zone 3 impedance relay,” International Journal of Electrical Power and Energy Systems., vol. 32, no. 9, pp. 998-1004, Now. 2010.
DOI
ScienceOn
|
16 |
K. El-Arroudi, G. Joos, and D. T. McGillis, “Operation of impedance protection relays with the STATCOM,” IEEE Trans. Power Del., vol. 17, no. 2, pp. 381-387, Apr. 2002.
DOI
ScienceOn
|