Browse > Article

The Capacity of Applying Electrical Resistance Probe in Natural Corrosion Tests of Vietnam  

Pham, Thy San (Corrosion Research Center, Institute for Material Science, NCST of Vietnam)
Le, Thi Hong Lien (Corrosion Research Center, Institute for Material Science, NCST of Vietnam)
Le, Quoc Hung (Corrosion Research Center, Institute for Material Science, NCST of Vietnam)
Publication Information
Corrosion Science and Technology / v.2, no.2, 2003 , pp. 98-101 More about this Journal
Abstract
The Electrical Resistance Probe of carbon steel and weight loss coupons were exposed in atmosphere and in the lake water of Hanoi. The comparison of data received by two methods after one year exposure was presented. The correspondence of the data of these methods on the exposure time in both environments showed a capacity of using Electrical Resistance Probe in Vietnamese natural corrosion testing of Carbon steel.
Keywords
the electrical resistance probe; weigh loss method; exposure time; carbon steel; environment;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A.Groysman and A. Hiram, in 13th ICC, Paper 148
2 Rohrback COSASCO System., 1998-1999 Corrosion Catalog
3 ISO 8407: Metals and Alloys - Procedure for removal of corrosion products from corrosion test specimens
4 K. oomichev, Zachita Metallov, 30, 419 (1994)
5 ISO 8407: Metals and Alloys - Procedure for removal of corrosion products from corrosion test specimens
6 K. A. Lichti, D. M. Firth, I. E. Minchington, and S. J. Swann, in 13th 1CC, Paper 412