Abstract
Effect of secondary air injection (SAI) on hydrocarbon reduction has been investigated in a single cylinder Sl engine operating at cold-steady/cold-start conditions. The hydrocarbon emission and exhaust gas temperature with and without catalytic converter were compared with continuous and synchronized SAIs, which injected secondary air intermittently into exhaust port. Effects of SAI location, SAI pressure, SAI timing, and location of catalytic converter have been investigated and the results are compared for both SAls with base condition. At cold-steady condition, the rate of HC reduction increased as the location of SAI was closer to the exhaust valve for both synchronized and continuous SAls. The emission of HC decreased with increasing exhaust-A/F when it was rich, and was relatively insensitive when it was lean. The timing of SAI in synchronized SAI had significant effect on HC reduction and exhaust gas temperature and the synchronized SAI was found to be more effective in HC reduction and exhaust gas temperature compared to the continuous SAI . At cold-start condition, when the catalytic converter was located 20 cm downstream from the exhaust port exit, the catalytic converter warm-up period for both SAls decreased by about 50%, and the accumulated hydrocarbon emission during the first 120 s decreased about by 56% and 22% with the synchronized and continuous SAIs, respectively, compared to that of the base condition.
Keywords
Secondary air injection (SAI); Synchronized SAI; Continuous SAI; Hydrocarbon, SI engine;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kollmann, K. and Zahn, W. (1994). Secondary air injection with a new developed electrical blower forreduced exhaust emission. SAE paper No. 940472
2 Kim, I. K., Lee, W. J., Yoon, J. S. and Park, C. K. (2001).An exploratory study of the the emission reductiontechnologies compliant with SULEV regulations. International Journal of Automotive technology 2, 2,63-75
3 Cheng, W. K., Summers, T. and Collings, N. (1998). Thefast-response flame ionization detector. Prog. EnergyCombust. Sci. 24, 89-124   DOI
4 Sim, H. S., Min, K. and Chung, S. H. (2000). Reducingexhaust HC emission at SI engine using continuousand synchronized secondary air injection. Seoul 2000F757E4,F2000H189
5 Sim, H. S., Min, K. and Chung, S. H. (2001). EfFect of synchronized secondary air injection on exhausthydrocarbon emission in a spark ignition engine.1MechE 215, Part D, D06800, 557-566
6 Yaegashi, T., Yoshizaki, K., Nagami, T. and Sugiura, S.(1994). New technology for reducing the powerconsumption of electrically heated catalyst. SAE Paper No. 940464
7 Ma, T, Collings, N. and Hands, T. (1992). Exhaust gasignition (EGI) - A new concept for rapid light-off of automotive exhaust catalysts. SAE paper No. 920400
8 Crane, M. E., Thring, R. H. and Podner, D. J. (1997).Reduced cold-start rapid exhaust port oxidation(REPO) in a spark-ignition engine. SAE paper No.970264