Abstract
The energy usage and the economical feasibility of the typical two story office building in the three urban locations of South Korea are evaluated as the eight orientations. The smallest energy consume is shown at the true south. The ranges of the low energy consume are $-3l5^{\circ}{\sim}0^{\circ}\;and\;-135^{\circ}{\sim}-180^{\circ}$. There are obvious advantages of passive solar designs such as using a fully glazed facade at the true south in the building. The General Low voltage plan is the effective way for the office building when does not required the high voltage electricity. The energy cost of KEPCO is compared to that of XCEL ENERGY. The portion of the customer charge of XCEL ENERGY is about 10% but it is about 50% of the total tariff of KEPCO. The effective way to save the energy cost is by reducing the operating energy of XCEL ENERGY plane but the most effective way is reduce the contracting energy of KEPCO plane.
Keywords
Orientation; eQUEST; LCC(Life-Cycle Cost); NPV(Net Present Value);
Citations & Related Records
연도 인용수 순위
  • Reference
1 Mari-Louise Persson, Arne Roos, Maria Wall,2006, Influence of window size on the energy balance of low energy houses, Energy and Buildings 38 , pp181–188   DOI   ScienceOn
2 http://doe2.com/equest/index.html
3 http://www.kosis.kr/
4 http://cyber.kepco.co.kr/cyber/personal/payment/paym ent_table/payment_table_eng.html
5 http://www.keei.re.kr
6 Harris Poirazis, ${A^{\circ}}$ ke Blomsterberg, Maria Wall, 2008, Energy simulations for glazed office buildings in Sweden, Energy and Buildings 40, pp 1161–1170   DOI   ScienceOn
7 Limor Shashua-Bara, Milo E. Hoffmana, 2003, Geometry and orientation aspects in passive cooling of canyon streets with trees, Energy and Buildings 35, pp 61–68   DOI   ScienceOn