Browse > Article
http://dx.doi.org/10.5999/aps.2013.40.2.117

Feasibility of Use of a Barbed Suture (V-Loc 180) for Quilting the Donor Site in Latissimus Dorsi Myocutaneous Flap Breast Reconstruction  

Thekkinkattil, Dinesh Kumar (Department of Oncoplastic Breast Surgery, Castle Hill Hospital, Hull and East Yorkshire Hospitals NHS Trust)
Hussain, Tasadooq (Department of Oncoplastic Breast Surgery, Castle Hill Hospital, Hull and East Yorkshire Hospitals NHS Trust)
Mahapatra, Tapan Kumar (Department of Oncoplastic Breast Surgery, Castle Hill Hospital, Hull and East Yorkshire Hospitals NHS Trust)
McManus, Penelope Louise (Department of Oncoplastic Breast Surgery, Castle Hill Hospital, Hull and East Yorkshire Hospitals NHS Trust)
Kneeshaw, Peter John (Department of Oncoplastic Breast Surgery, Castle Hill Hospital, Hull and East Yorkshire Hospitals NHS Trust)
Publication Information
Archives of Plastic Surgery / v.40, no.2, 2013 , pp. 117-122 More about this Journal
Abstract
Background Latissimus dorsi (LD) myocutaneous flap is a popular method of breast reconstruction which can be associated with high incidence of seroma formation. Quilting sutures at the harvest site are used to reduce this. Barbed sutures are self anchoring sutures which avoid multiple knotting and can be useful in quilting. Methods A retrospective analysis of prospectively maintained database of patients who underwent LD flap breast reconstruction between January 2009 and January 2011 was carried out. Seroma formation at the harvest site, wound related complications, inpatient stay and duration of surgery were analysed and a comparison was made between two groups where quilting was done with barbed (V-Loc) suture and conventional polydioxanone (PDS) II sutures. Results Fifty-seven patients were included of which 33 had quilting by V-Loc sutures and in 24 patients PDS II suture was used. Median age in the PDS group was 55 years (interquartile range [IQR)], 45 to 61 years) which was comparable to the V-Loc group (53 years [IQR, 48 to 59 years]; P-value 0.948). Sixteen patients (28%) had significant seroma formation and 5 (9%) patients developed superficial wound dehiscence. Incidences of seroma or wound complications were comparable (P-value 0.378 and 1.00, respectively). Secondary outcomes such as total duration of surgery, total inpatient stay, total amount of drain at the donor site were also similar in two groups. Conclusions Use of barbed sutures for quilting the donor site in LD flap reconstruction is a feasible option and the associated seroma formation and wound complications are comparable with conventional sutures.
Keywords
Barbed suture; V-Loc; Quilting; Seroma; Latissimus dorsi flap;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Clough KB, Louis-Sylvestre C, Fitoussi A, et al. Donor site sequelae after autologous breast reconstruction with an extended latissimus dorsi flap. Plast Reconstr Surg 2002;109: 1904-11.   DOI
2 Rios JL, Pollock T, Adams WP Jr. Progressive tension sutures to prevent seroma formation after latissimus dorsi harvest. Plast Reconstr Surg 2003;112:1779-83.   DOI
3 Weinrach JC, Cronin ED, Smith BK, et al. Preventing seroma in the latissimus dorsi flap donor site with fibrin sealant. Ann Plast Surg 2004;53:12-6.   DOI
4 Cha HG, Kang SG, Shin HS, et al. Does fibrin sealant reduce seroma after immediate breast reconstruction utilizing a latissimus dorsi myocutaneous flap? Arch Plast Surg 2012;39:504-8.   DOI
5 Shin IS, Lee DW, Lew DH. Efficacy of quilting sutures and fibrin sealant together for prevention of seroma in extended latissimus dorsi flap donor sites. Arch Plast Surg 2012;39: 509-13.   DOI
6 Menke H, Erkens M, Olbrisch RR. Evolving concepts in breast reconstruction with latissimus dorsi flaps: results and follow-up of 121 consecutive patients. Ann Plast Surg 2001; 47:107-14.   DOI
7 Bacilious N, Kulber DA, Peters ED, et al. Harvesting of the latissimus dorsi muscle: a small animal model for seroma formation. Microsurgery 1995;16:646-9.   DOI
8 Jain PK, Sowdi R, Anderson AD, et al. Randomized clinical trial investigating the use of drains and fibrin sealant following surgery for breast cancer. Br J Surg 2004;91:54-60.   DOI
9 Daltrey I, Thomson H, Hussien M, et al. Randomized clinical trial of the effect of quilting latissimus dorsi flap donor site on seroma formation. Br J Surg 2006;93:825-30.   DOI
10 Sierra DH, Feldman DS, Saltz R, et al. A method to determine shear adhesive strength of fibrin sealants. J Appl Biomater 1992;3:147-51.   DOI
11 Cipolla C, Fricano S, Vieni S, et al. Does the use of fibrin glue prevent seroma formation after axillary lymphadenectomy for breast cancer? A prospective randomized trial in 159 patients. J Surg Oncol 2010;101:600-3.   DOI
12 Callaghan CJ, Couto E, Kerin MJ, et al. Breast reconstruction in the United Kingdom and Ireland. Br J Surg 2002;89: 335-40.   DOI
13 McKenzie AR. An experimental multiple barbed suture for the long flexor tendons of the palm and fingers: preliminary report. J Bone Joint Surg Br 1967;49:440-7.   DOI
14 Greenberg JA. The use of barbed sutures in obstetrics and gynecology. Rev Obstet Gynecol 2010;3:82-91.
15 Kim JC, Lee YK, Lim BS, et al. Comparison of tensile and knot security properties of surgical sutures. J Mater Sci Mater Med 2007;18:2363-9.   DOI
16 Molokova OA, Kecherukov AI, Aliev F, et al. Tissue reactions to modern suturing material in colorectal surgery. Bull Exp Biol Med 2007;143:767-70.   DOI
17 Murtha AP, Kaplan AL, Paglia MJ, et al. Evaluation of a novel technique for wound closure using a barbed suture. Plast Re constr Surg 2006;117:1769-80.   DOI
18 Parikh PM, Davison SP, Higgins JP. Barbed suture tenorrhaphy: an ex vivo biomechanical analysis. Plast Reconstr Surg 2009;124:1551-8.   DOI
19 Delay E, Gounot N, Bouillot A, et al. Autologous latissimus breast reconstruction: a 3-year clinical experience with 100 patients. Plast Reconstr Surg 1998;102:1461-78.   DOI
20 Hogstrom H, Haglund U, Zederfeldt B. Tension leads to increased neutrophil accumulation and decreased laparotomy wound strength. Surgery 1990;107:215-9.
21 Mulholland RS, Paul MD. Lifting and wound closure with barbed sutures. Clin Plast Surg 2011;38:521-35.   DOI
22 van Rijssel EJ, Brand R, Admiraal C, et al. Tissue reaction and surgical knots: the effect of suture size, knot configuration, and knot volume. Obstet Gynecol 1989;74:64-8.
23 Rosen AD. Use of absorbable running barbed suture and progressive tension technique in abdominoplasty: a novel approach. Plast Reconstr Surg 2010;125:1024-7.   DOI
24 Bailey SH, Oni G, Guevara R, et al. Latissimus dorsi donorsite morbidity: the combination of quilting and fibrin sealant reduce length of drain placement and seroma rate. Ann Plast Surg 2012;68:555-8.   DOI
25 Tomita K, Yano K, Masuoka T, et al. Postoperative seroma formation in breast reconstruction with latissimus dorsi flaps: a retrospective study of 174 consecutive cases. Ann Plast Surg 2007;59:149-51.   DOI