Browse > Article
http://dx.doi.org/10.5999/aps.2012.39.4.309

Application of Virtual Surgical Planning with Computer Assisted Design and Manufacturing Technology to Cranio-Maxillofacial Surgery  

Zhao, Linping (The Craniofacial Center, University of Illinois Medical Center)
Patel, Pravin K. (The Craniofacial Center, University of Illinois Medical Center)
Cohen, Mimis (The Craniofacial Center, University of Illinois Medical Center)
Publication Information
Archives of Plastic Surgery / v.39, no.4, 2012 , pp. 309-316 More about this Journal
Abstract
Computer aided design and manufacturing (CAD/CAM) technology today is the standard in manufacturing industry. The application of the CAD/CAM technology, together with the emerging 3D medical images based virtual surgical planning (VSP) technology, to craniomaxillofacial reconstruction has been gaining increasing attention to reconstructive surgeons. This article illustrates the components, system and clinical management of the VSP and CAD/CAM technology including: data acquisition, virtual surgical and treatment planning, individual implant design and fabrication, and outcome assessment. It focuses primarily on the technical aspects of the VSP and CAD/CAM system to improve the predictability of the planning and outcome.
Keywords
Computer aided design and manufacturing; Computer assisted image processing; Computer-assisted surgery; Reconstructive surgical procedures; Three-dimensional imaging;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Joffe JM, McDermott PJ, Linney AD, et al. Computer-generated titanium cranioplasty: report of a new technique for repairing skull defects. Br J Neurosurg 1992;6:343-50.   DOI   ScienceOn
2 Binder WJ, Kaye A. Reconstruction of posttraumatic and congenital facial deformities with three-dimensional computer- assisted custom-designed implants. Plast Reconstr Surg 1994;94:775-85.   DOI   ScienceOn
3 Tanaka Y, Matsumoto K, Song S, et al. Reconstruction of a cranial bone defect with hydroxyapatite and free flap transfer. J Craniofac Surg 1997;8:141-5.   DOI   ScienceOn
4 Fukuta F, Jackson IT, McEwan CM, et al. Three- dimensional imaging in craniofacial surgery: a review of the role mirror image production. Eur J Plast Surg 1990;13:209-17.   DOI   ScienceOn
5 Altobelli DE, Kikinis R, Mulliken JB, et al. Computer-assisted three-dimensional planning in craniofacial surgery. Plast Reconstr Surg 1993;92:576-85.   DOI   ScienceOn
6 Hildebolt CF, Vannier MW. Three-dimensional measurement accuracy of skull surface landmarks. Am J Phys Anthropol 1988;76:497-503.   DOI   ScienceOn
7 Hildebolt CF, Vannier MW, Knapp RH. Validation study of skull three-dimensional computerized tomography measurements. Am J Phys Anthropol 1990;82:283-94.   DOI   ScienceOn
8 Lo LJ, Marsh JL, Vannier MW, et al. Craniofacial computerassisted surgical planning and simulation. Clin Plast Surg 1994;21:501-16.
9 Cavalcanti MG, Vannier MW. Quantitative analysis of spiral computed tomography for craniofacial clinical applications. Dentomaxillofac Radiol 1998;27:344-50.   DOI   ScienceOn
10 Lo LJ, Lin WY, Wong HF, et al. Quantitative measurement on three-dimensional computed tomography: an experimental validation using phantom objects. Chang Gung Med J 2000;23:354-9.
11 Cavalcanti MG, Rocha SS, Vannier MW. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications. Dentomaxillofac Radiol 2004;33: 170-6.   DOI   ScienceOn
12 Hounsfield GN. Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 1973;46:1016-22.   DOI   ScienceOn
13 Ambrose J. Computerized transverse axial scanning (tomography).2. Clinical application. Br J Radiol 1973;46:1023-47.   DOI   ScienceOn
14 Eufinger H, Wehmoller M, Harders A, et al. Prefabricated prostheses for the reconstruction of skull defects. Int J Oral Maxillofac Surg 1995;24:104-10.   DOI   ScienceOn
15 Metzger MC, Hohlweg-Majert B, Schwarz U, et al. Manufacturing splints for orthognathic surgery using a three-dimensional printer. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:e1-7.   DOI
16 Vannier MW, Marsh JL, Warren JO. Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. Radiology 1984;150:179-84.   DOI
17 Toth BA, Ellis DS, Stewart WB. Computer-designed prostheses for orbitocranial reconstruction. Plast Reconstr Surg 1988;81:315-24.   DOI   ScienceOn
18 Robb RA. Biomedical imaging, visualization, and analysis. New York: Wiley-Liss; 2000.
19 Woolson ST, Dev P, Fellingham LL, et al. Three-dimensional imaging of bone from computerized tomography. Clin Orthop Relat Res 1986;(202):239-48.
20 Solar P, Ulm C, Lill W, et al. Precision of three-dimensional CT-assisted model production in the maxillofacial area. Eur Radiol 1992;2:473-7.
21 Eufinger H, Wehmoller M, Machtens E, et al. Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. J Craniomaxillofac Surg 1995;23:175-81.   DOI   ScienceOn
22 Wehmoller M, Eufinger H, Kruse D, et al. CAD by processing of computed tomography data and CAM of individually designed prostheses. Int J Oral Maxillofac Surg 1995;24:90-7.   DOI   ScienceOn
23 Klein HM, Schneider W, Alzen G, et al. Pediatric craniofacial surgery: comparison of milling and stereolithography for 3D model manufacturing. Pediatr Radiol 1992;22:458-60.   DOI   ScienceOn
24 Housholder R. Molding process. US Patent 4,247,508. Filed December 3, 1979. Published January 27, 1981.
25 Hull CW. Apparatus for production of three-dimensional objects by stereolithography. US Patent 4,575,330. Filed Aug 8, 1984. Published March 11, 1986.
26 Deckard C. Method and apparatus for producing parts by selective sintering. U.S. Patent 4,863,538, Filed October 17, 1986. Published September 5, 1989.
27 McGurk M, Amis AA, Potamianos P, et al. Rapid prototyping techniques for anatomical modelling in medicine. Ann R Coll Surg Engl 1997;79:169-74.
28 Lopes PM, Moreira CR, Perrella A, et al. 3-D volume rendering maxillofacial analysis of angular measurements by multislice CT. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:224-30.   DOI   ScienceOn
29 Moreira CR, Sales MA, Lopes PM, et al. Assessment of linear and angular measurements on three-dimensional conebeam computed tomographic images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;108:430-6.   DOI   ScienceOn
30 Berco M, Rigali PH Jr, Miner RM, et al. Accuracy and reliability of linear cephalometric measurements from conebeam computed tomography scans of a dry human skull. Am J Orthod Dentofacial Orthop 2009;136:17.e1-9.   DOI
31 Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 2011;14:1-16.   DOI   ScienceOn
32 Cynthia DB, Steven S, Anil M, et al. A survey of interactive mesh-cutting techniques and a new method for implementing generalized interactive mesh cutting using virtual tools. J Visual Comput Animat 2002;13:21-42.   DOI   ScienceOn
33 Zachow S, Gladilina E, Saderb R, et al. Draw and cut: intuitive 3D osteotomy planning on polygonal bone models. Int Congr Ser 2003;1256:362-9.   DOI
34 Westermark A, Zachow S, Eppley BL. Three-dimensional osteotomy planning in maxillofacial surgery including soft tissue prediction. J Craniofac Surg 2005;16:100-4.   DOI   ScienceOn
35 Lane C, Harrell W Jr. Completing the 3-dimensional picture. Am J Orthod Dentofacial Orthop 2008;133:612-20.   DOI   ScienceOn
36 Chua CK, Chou SM, Ng WS, et al. An integrated experimental approach to link a laser digitiser, a CAD/CAM system and a rapid prototyping system for biomedical applications. Int J Adv Manuf Technol 1998;14:110-5.   DOI   ScienceOn
37 Xia JJ, Gateno J, Teichgraeber JF. Three-dimensional computer- aided surgical simulation for maxillofacial surgery. Atlas Oral Maxillofac Surg Clin North Am 2005;13:25-39.   DOI   ScienceOn
38 MIMICS version 12 reference guide. Leuven (BE): Materialise N.V.; 2009.
39 Sailer HF, Haers PE, Zollikofer CP, et al. The value of stereolithographic models for preoperative diagnosis of craniofacial deformities and planning of surgical corrections. Int J Oral Maxillofac Surg 1998;27:327-33.   DOI   ScienceOn
40 Santler G, Karcher H, Ruda C. Indications and limitations of three-dimensional models in cranio-maxillofacial surgery. J Craniomaxillofac Surg 1998;26:11-6.   DOI   ScienceOn