Browse > Article

Comparison of Physical & Histological Change of Alloplastic Implants after Implantation in Rat  

Kim, Sung Nam (Department of Plastic and Reconstructive Surgery, Chonnam National University Medical School)
Noh, Bok Kyun (Department of Plastic and Reconstructive Surgery, Chonnam National University Medical School)
Kim, Eui Sik (Department of Plastic and Reconstructive Surgery, Chonnam National University Medical School)
Hwang, Jae Ha (Department of Plastic and Reconstructive Surgery, Chonnam National University Medical School)
Kim, Kwang Seog (Department of Plastic and Reconstructive Surgery, Chonnam National University Medical School)
Lee, Sam Yong (Department of Plastic and Reconstructive Surgery, Chonnam National University Medical School)
Cho, Bek Hyun (Bella Plastic Surgery Clinic)
Publication Information
Archives of Plastic Surgery / v.33, no.2, 2006 , pp. 219-224 More about this Journal
Abstract
Augmentation rhinoplasty is one of the most popular aesthetic procedure in Asians. Numerous alloplastic implants have been used until now, but no accurate comparative analysis about the implant materials has been reported yet. This study in animal model was designed to determine the safety and effectiveness of various implant materials in augmentation rhinoplasty. The $15{\times}15{\times}2mm$ sized square shaped plate of $Gore-Tex^{(R)}$, silicone rubber, and $15{\times}15{\times}1.5mm$ sized $Medpor^{(R)}$ were implanted under panniculus carnosus of the abdomen wall of rat. And tissue specimens including the implant and surrounding soft tissue were obtained by en bloc excision in 6 months after implantation. The implants were estimated in weight and volume, and also the specimens were examined grossly and microscopically. The results revealed that increase of average weight 26.9%, decrease of average volume 55.4% in $Gore-Tex^{(R)}$ implant, increase of each average weight and volume 62.6%, 8.7% in $Medpor^{(R)}$ implant and very slight increase of both average weight and volume 4.7%, 1.1% in silicone rubber implant. Grossly, the $Gore-Tex^{(R)}$ was deformed, $Medpor^{(R)}$ was strongly adherent to surrounding soft tissue and the silicone rubber was well encapsulated and easily peeled off. Microscopically, silicone rubber showed foreign body reaction slightly and there were no inflammatory responses in all alloplastic implants. In our study, silicone rubber showed very proper alloplastic features for augmentation rhinoplasty due to causing no inflammatory response, no physical change, and no deformity.
Keywords
Alloplastic implant; $Gore-Tex^{(R)}$; Silicone rubber; $Medpor^{(R)}$;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Godin MS, Waldman SR, Johnson CM Jr: The use of expanded polytetrafluoroethylene(Gore-TexR) in rhinoplasty. A 6-year experience. Arh Otolaryngol Head Neck Surg 121: 1131, 1995   DOI   ScienceOn
2 Vistnes LM, Ksander GA, Kosk J: Study of encapsulation of silicone rubber implants in animal: A foreign body reaction. Plast Reconstr Surg 62: 580, 1978   DOI   ScienceOn
3 Seo SW, Cho ST, Cho YK, Whang KW, Cha DS: The clinical use of various nasal implants in rhinoplasty. J Korean Soc Plast Reconstr Surg 27: 204, 2000
4 Lam SM, Kim YK: Augmentation rhinoplasty of the Asian nose with the 'bird' silicone implant. Ann Plast Surg 51: 249, 2003   DOI   ScienceOn
5 Holmes RE: Alloplastic implants. In McCarthy JG(ed): Plastic surgery. 1st ed, Philadelphia, W.B. Saunders Co., 1990, p 698
6 Soyer T, Lempinen M, Cooper P, Norton L, Eiseman B: A new venous prosthesis. Surgery 72: 864, 1972
7 Neel HB 3rd: Implants of Gore-TexR. Arch Otolaryngol 109: 427, 1983   DOI
8 Zeng Y, Wu W, Yu H, Yang J, Chen G: Silicone implant in augmentation rhinoplasty. Ann Plast Surg 49: 495, 2002   DOI   ScienceOn
9 Yoo JH, Koo BJ, Kim KS: The clinical use of high density polythylene implants(MedporR) in nasal tip plasty. J Korean Soc Plast Reconstr Surg 22: 127, 1995
10 Lew DH, Kim SM, Ahn SJ, Park BY: Histomorphometric study of tissue reaction of Gore-TexR implant in the rat model. J Korean Soc Plast Reconstr Surg 27: 247, 2000
11 Yang SJ, Lee JH, Tark MS: Problems of expanded polytetrafluoroethylene(Gore-TexR) in augmentation rhinoplasty. J Korean Soc Plast Reconstr Surg 31: 28, 2004