Browse > Article
http://dx.doi.org/10.5487/TR.2008.24.1.023

Voltammetric Assay of Mercury Ion in Fish Kidneys  

Ly, Suw-Young (Biosensor Research Institute, Seoul National University of Technology)
Publication Information
Toxicological Research / v.24, no.1, 2008 , pp. 23-28 More about this Journal
Abstract
Voltammetric analysis of mercury ions was developed using paste electrodes (PEs) with DNA and carbon nanotube mixed electrodes. The optimized analytical results of the cyclic voltammetry (CV) of the $1{\sim}14ng\;L^{-1}Hg(II)$ concentration and the square wave (SW) stripping voltammetry of the $1{\sim}12ng\;L^{-1}Hg(II)$ working range within an accumulation time of 400 seconds were obtained in 0.1 M $NH_4H_2PO_4$ electrolyte solutions of pH 4.0. For the relative standard deviations of the $1ng\;L^{-1}Hg(II)$, which were observed at 0.078% (n = 15) at the optimum conditions, the low detection limit (S/N) was pegged at $0.2ng\;L^{-1}(7.37{\times}10^{-13}M)$ for Hg(II). The results can be applied to assays in biological fish kidneys and wastewater samples.
Keywords
Hg(II); DNA; Carbon nanotube; Voltammetry; Fish kidney;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Carrington, C.D., Montwill, B. and Bolger, P.M. (2004). An intervention analysis for the reduction of exposure to methylmercury from the consumption of seafood by women of child-bearing age. Reg. Toxicol. Pharmacol., 40, 272-280   DOI   ScienceOn
2 Korbut, O., Buckova, M., Tarapcik, P., Labuda, J. and Grundler, P. (2001). Damage to DNA indicated by an electrically heated DNA-modified carbon paste electrode. J. Electroanal. Chem., 506,143-148   DOI   ScienceOn
3 Niels, P.R.A., Per, H.H. and Dieter, B. (1996). Using the electrochemical quartz crystal microbalance as stripping detector. Application to trace mercury analysis. Anal. Chim. Acta, 329, 253-256   DOI   ScienceOn
4 Percio, A.M.F., Angela, L.R.W., Margarida, B.R.B., Adriana, T.S. and Arnaldo, A.C. (2003). Cathodic adsorptive stripping voltammetric behaviour of guanine in the presence of copper at the static mercury drop electrode. Talanta, 61, 829-835   DOI   ScienceOn
5 Ricardo, D.R., Matthieu, W., Philippe, M. and Christian, J.C. (2000). Measurements of trace concentrations of mercury in sea water by stripping chronopotentiometry with gold disk electrode: influence of copper. Anal. Chim. Acta, 410, 97-105   DOI   ScienceOn
6 Sang, H.K., Dae, K.K., Tae, Y.S. and Cheol, H.C. (2004). Differential alterations of endotoxin induced cytokine expression and mitogen activated protein kinase activation by mercure in mouse kidney. J. Toxicol. Pub, Health, 20, 233-239   과학기술학회마을
7 Sonia, M.S. (1998). Determination of lead in the absence of supporting electrolyte using carbon fiber ultramicroelectrode without mercury film. Electroanalysis, 10, 722-725   DOI   ScienceOn
8 Tesfaye, H.D., Bhagwan, S.C. and Hailemichael, A. (1999). Electrode, differential pulse anodic stripping voltammetric determination of Lead(II) with N p chlorophenylcinnamohydroxamic acid modified carbon paste electrode. Electroanalysis, 17, 1305-1311
9 Van Staden, J.F. and Taljaard, R.E. (2004). Determination of Lead(II), Copper(II), Zinc(II), Cobalt(II), Cadmium(II), Iron(III), Mercury(II) using sequential injection extractions. Talanta, 64, 1203-1212   DOI   ScienceOn
10 Zuliang, C., Zahra, P. and Hibbert, D.B. (1999). Stripping voltammetry of Pb(II), Cu(II), and Hg(II) at a nafin-coated glassy carbon electrode modifid by neutralionophores. Electroanalysis, 11, 964-968   DOI
11 Radi, A. (1999). Voltammetric study of khellin at a DNAcoated carbon paste electrode. Anal. Chim. Acta, 386, 63-68   DOI   ScienceOn
12 Sholupov, S., Pogarev, S., Ryzhov, V., Mashyanov, N. and Stroganov, A. (2004). Zeeman atomic absorption spectrometer RA-915+ for direct determination of mercury in air and complex matrix samples. Fuel Proc. Technol., 85, 473-485   DOI   ScienceOn
13 Gang, W., Jing, J.X. and Hong, Y.C. (2002). Interfacing cytochrome Interfacing cytochrome c to electrodes with a DNA-carbonnanotube composite film. Electrochem. Commun., 4, 506-509   DOI   ScienceOn
14 Janos, V. and Erzsebet, B. (2005). Mercury content of the cultivated mushroom Agaricus bisporus. Food Cont., 16, 113-116   DOI   ScienceOn
15 Cizdziel, J.V. and Shawn, G. (2004). Determination of total mercury in human hair and animal fur by combustion atomic absorption spectrometry. Talanta, 64, 918-921   DOI   ScienceOn
16 Li, M.D., Xiu, P.Y., Yan, L., Yan, J., Shan, W.W. and Dong, Q.J. (2004). On-line coupling of flow injection displacement sorption preconcentration to high-performance liquid chromatography for speciation analysis of mercury in seafood. J. Chromato. A, 1036, 119-125   DOI   ScienceOn
17 Suw, Y.L., Jung, I.C., Young, S.J., Woon, W.J., Hye, J.L. and Seong, H.L. (2004). Electrochemical detection of ascorbic acid (vitamin C) using a glassy carbon electrode. Nahrung/Food, 48, 201-204   DOI   ScienceOn
18 Yuan, D.Z., Dai, W.P., Shen, H., Zong, L.W., Jiem, K.C. and Hongm, P.D. (1999). DNA-modified electrodes; part 4: optimization of covalent immobilization of DNA on selfassembled monolayers. Talanta, 49, 751-756   DOI   ScienceOn
19 Ertas, O.S. and Tezel, H. (2004). A validated cold vapour-AAS method for determining mercury in human red blood cells. J. Pharmaceut. Biomed. Anal., 36, 893-897   DOI   ScienceOn
20 Joanna, B. and Michael, G. (2001). Metals in albatross feathers from midway atoll: Influence of species, age, and nest location. Environ. Res. Section A, 82, 207-221
21 Eun, S.C., Kuk, R.K., Sun, T.Y., Myung, H.K., Byung, W.M. and Hyun, W.C. (2003). Localization of methyl mercury chloride in the reoroductive tract of male mice, J. Toxicol. Pub. Health, 19, 153-159   과학기술학회마을
22 Joseph, W., Jianmin, L., Suw, Y.L., Maika, V., Baomin, T., William, K.A. and Ruben, A.A. (2000). Lab-on-a-cable for electrochemical monitoring of phenolic contaminants. Anal. Chem., 72, 2659-2663   DOI   ScienceOn
23 Joseph, W., Beatriz, S., Suw, Y.L., Jianmin, L. and Jose, M.P. (2001). Determination of micromolar bromate concentrations by adsorptive-catalytic stripping votammetry of the molybdenum-3-methoxy-4-hydroxymandelic acid complex. Talanta, 54, 147-151   DOI   ScienceOn
24 Giuseppe, C., Elisa, B.G. and Alfredo, S.M. (2004). Multielemental speciation analysis of organometallic compounds of mercury, lead and tin in natural water samples by headspace-solid phase microextraction followed by gas chromatography-mass spectrometry. J. Chromato. A, 1034, 191-197   DOI   ScienceOn
25 Tsai, H.L., Jing, F.H. and Wen, S.I. (2001). Perfluorinated anion-exchange polymer mercury film electrode for anodic stripping voltammetric determination of zinc(II): effect of model organic compounds. Anal. Chim. Acta, 21701, 1-8
26 Suw, Y.L., Duck, H.K. and Myung, H.K. (2002). Square-wave cathodic stripping voltammetric analysis of RDX using mercury-film plated glassy carbon electrode. Talanta, 58, 919-926   DOI   ScienceOn
27 Seung, J.K., Gyu, S.R., Soon, S.K., Kyung, H.S., So, H.K., Soo, Y.C., Yo, W.C., Yong, H.W. and Kui, L.P. (2003). Study on the developmental toxicity of thimerosal. J. Toxicol. Pub. Health, 19, 267-275
28 Clinio, L. and Giancarlo, T. (2001). Voltammetric trace metal determinations by cathodic and anodic stripping voltammetry in environmental matrices in the presence of mutual interference. J. Electroanal. Chemi., 509, 80-89   DOI   ScienceOn
29 Petru, J. and Freddy, C.A. (2004). Speciation analysis of mercury by solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasmatime-of-flight-mass spectrometry. J. Chromato. A, 1055, 197-207   DOI   ScienceOn
30 Bailure, S.S., Wlodzimierz, K. and Francis, D. (2003). Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes. Electroanalysis, 9, 753-772
31 Li, N.L., Gui, B.J., Jing, F.L. and Jing, T.H. (2003). Speciation analysis of mercury in seafood by using high-performance liquid chromatography on-line coupled with coldvapor atomic fluorescence spectrometry via a post column microwave digestion. Anal. Chim. Acta, 477, 131-137   DOI   ScienceOn
32 Jahan, B.R., Reza, O. and Abolfazl, K. (2001): Carbon paste electrode spiked with ferrocene carboxylic acid and its application to the electrocatalytic determination of ascorbic acid. J. Electroanal. Chem., 515, 45-51   DOI   ScienceOn
33 Nathalie, A., Oscar, K., Tom, K. and Ben, A. (2005). Low-level methylmercury exposure as a risk factor for neurologic abnormalities in adults. Neurotoxicology, 26, 149-157   DOI   ScienceOn
34 Claudia, M.V., Genilson, P.S., Rodinei, A., Fernando, B.E.F. and Claudia, C.W. (2005). Speciation and quantication of mercury in Oxisol, Ultisol, and Spodosol from Amazon (Manaus, Brazil). Chemosphere, 58, 779-792   DOI   ScienceOn
35 Manivannan, A., Ramakrishnan, L., Seehra, M.S., Granite, E., Butler, J.E., Tryk, D.A. and Fujishima, A. (2005). Mercury detection at boron doped diamond electrodes using a rotating disk technique. J. Electroanal. Chem., 577, 287-293   DOI   ScienceOn
36 Manli, G., Jinhua, C., Lihua, N. and Shouzhuo, Y. (2004). Electrostatic assembly of calf thymus DNA on multi-walled carbon nanotube modified gold electrode and its interaction with chlorpromazine hydrochlorid. Electrochim. Acta, 49, 2637-2643   DOI   ScienceOn
37 Manli, G., Jinhua, C., Dengyou, L., Lihua, N. and Shouzhuo, Y. (2004). Electrochemical characteristics of the immobilization of calf thymus DNA molecules on multi-walled carbon nanotubes. Bioelectrochemistry, 62, 29-35   DOI   ScienceOn
38 Shigehiro, K., Yoshiharu, K., Yuka, S. and Kiyoshi, H. (2004). Rapid determination of total mercury in treated waste water by cold vapor atomic absorption spectrometry in alkaline medium with sodium hypochlorite solution. Talanta, 64, 554-557   DOI   ScienceOn