Browse > Article
http://dx.doi.org/10.9726/kspse.2012.16.2.017

Computational Thermal Flow Analysis of a Cabin Cooler for a Commercial Vehicle  

Kim, J.K. (Department of Power System Engineering, KunSan National University)
Oh, S.H. (School of Mechanical and Automative Engineering, KunSan National University.)
Publication Information
Journal of Power System Engineering / v.16, no.2, 2012 , pp. 17-23 More about this Journal
Abstract
The steady three-dimensional computational thermal flow analysis using standard k-${\varepsilon}$ turbulence model was carried out to investigate the heat transfer characteristics of a cabin cooler for a commercial vehicle. The heat exchanging method of this cabin cooler is to use the cooling effect of a thermoelectric module. In view of the results so far achieved, the air system resistance of a cabin cooler is about 12.4 Pa as a static pressure, and then the operating point of a cross-flow fan considering in this study is formed in the comparatively low flowrate region. The air temperature difference obtained from the cold part of an thermoelectric module is about $26^{\circ}C$, and the cooling water temperature difference obtained from the hot part of an thermoelectric module is about $3.5^{\circ}C$.
Keywords
Cabin Cooler; Commercial Vehicle; Computational Thermal Flow Analysis; Heat Sink; Heat Transfer; Standard k-${\varepsilon}$ Turbulence Model; Thermoelectric Module; Water Jacket;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 G. S. Attey, 1998, "Enhanced Thermoelectric Refrigeration System COP through Low Thermal Impedance Liquid Heat Transfer System", Proc. of the 17th International Conference on Thermo-electrics, pp. 519-524.
2 B. H. Kang, H. J. Chang and S. Y. Kim, 2002, "Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner", Korean J. of Refrigeration and Air Conditioning Engineering, Vol. 14, No. 3, pp. 482-488.
3 D. Astrain, J. G. Vian and M. Dominguez, 2003, "Increase of COP in the Thermoelectric Refrigera- tion by the Optimization of Heat Dissipation", Applied Thermal Eng. Vol. 23, pp. 2183-2200.   DOI   ScienceOn
4 J. G. Vian and D. Astrain, 2008, "Development of a Heat Exchanger for the Cold Side of a Thermoelectric Module", Applied Thermal Eng. Vol. 28, pp. 1514-1521.   DOI   ScienceOn
5 B. J. Huang, C. J. Chin and C. L. Duang, 2000, "A Design Method of Thermoelectric Cooler", Int. J. Refrigeration, Vol. 23, pp. 208-218.   DOI   ScienceOn
6 S. Y. Yoo, C. P. Hong and W. S. Shim, 2004, "A Study on the Performance of Thermoelectric Module and Thermoelectric Cooling System", Korean J. of Air- Conditioning and Refrigeration Engineering, Vol. 16, No. 1, pp. 62-69.   과학기술학회마을
7 J. Hwang and B. H. Kang, 2006, "An Experimental Study on the Optimal Operation Condition of an Air-Cooler using Thermoelectric Modules", Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 18, No. 1, pp. 66-72.   과학기술학회마을
8 J. S. Kim, Y. B. Im and W. H. Cho, 2004, "The Experimental Study on Cooling-Heating System using Thermoelectric Module and Parallel Flow Type Oscillating Heat Pipe", Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 8, pp. 741-747.   과학기술학회마을
9 J. Kim, C. H. Park, Y. T. Kang and C. K. Choi, 2003, "Heat Transfer Analysis for Optimum Design of a Thermoelectric Cooler", Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 15, No. 11, pp. 889-894.   과학기술학회마을
10 K. H. Lee and O. J. Kim, 2006, "Effect of the Thermoelectric Element Thickness on the Thermal Performance of the Thermoelectric Micro-Cooler", Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 18, No. 3, pp. 211-217.   과학기술학회마을
11 SC/Tetra(Version 8), 2010, User's Guide, Software Cradle Co., Ltd.