Browse > Article

A Comparison of Legionella and Bacteria etc. microbe distribution and correlation in Cooling Towers Water  

방선재 (건국대학교 환경공학과)
이철민 (한양대학교 환경 및 산업의학연구소)
김윤신 (한양대학교 환경 및 산업의학연구소)
선우영 (건국대학교 환경공학과)
박용배 (경기도보건환경연구원북부지원)
Publication Information
Journal of environmental and Sanitary engineering / v.17, no.3, 2002 , pp. 1-6 More about this Journal
Abstract
This study was carried out to investigate the distribution of Legionella spp and microbe from cooling towers water of Public establishments in Seoul and Gyeonggi-Do. As results of this study, the cooling tower 132 sites were detecting L. pneumophila in order to July(12%) > August (14%) > June, September no-detected. The public establishments were detecting L. pneumophila in order to Department store(27.3%) > Hospital(8.7%) > Office(5.9%) > Big Mart(5.0%) > Hotel, Subway no-detected. The correlation coefficient pH and L.pneumophila showed 0.62(p=0.05), 0.27(p=0.45) in temperature and L.pheumophila, 0.40(p=0.25) in turbidity and L.pneumophila.
Keywords
Legionella pneumophila; Cooling Towers Water; Environmental factor;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 /
[ 국립보건원 ] / 개정 감염병 실험실 진단지침
2 /
[ 厚生省 生活衛牛局 企劃課 ] / Legionellosis 防止指針
3 /
[ 환경부 ] / 먹는물수질공정시험법(222.7.1개정)
4 Growth of legionella pneumophila in two membered culturer with green algae and cyanobacteria /
[ Pope,D.H.;R.J.Soracco;H.K.Gill;C.B.Fliermans ] / Curr. Microbil   DOI
5 서울시내 다중이용시설 냉각탑수의 레지오넬라균 분포 및 혈청학적특성 /
[ 박석기;황영옥;정지헌;정윤태 ] / 서울시보건환경연구원보
6 Ecological distribution of Legionella Pneumophila /
[ Fliermans,C.B.;Cherry,W.B.;Orrison,L.H.;Smith,S.J.;Tison,D.L.;Pop,D.H. ] / Appl. Environ. Mocrobiol.
7 실내공기오염에 관한 보건학적 고찰 /
[ 김윤신 ] / 대한보건협회지   과학기술학회마을
8 Legionella spp.의 감염 및 분포에 관한 연구 /
[ 이용우;성원근;오현수;오희복;박미연;이명숙;박경식;백승복 ] / 국립보건원보
9 1984년 7월 K병원 중환자실을 중심으로 집단발생한 비폐렴성 Legionellosis (Pontiac fever)에 관한 역학적 연구 /
[ 김정순;이성우;심한섭;오대규;조민기;오희복;우세홍;정윤섭 ] / 한국역학회지
10 Legionaires disease: Isolation of a bacterium and demonstration of its role in other respiratory disease /
[ McDade J.E.;Shepard C.C.;Fraser D.W.;Tasi T.R.;Redus M.A.;Dowdle W.R. ] / N. Engl. J. Med.   DOI   ScienceOn
11 Growth of Legionella pneumophila in association with blue-green algae(Cyanobacteria) /
[ Tison,D.L.;Pope,D.H.;Cheerry,W.B.;Fliermas,C.B. ] / Appl. Environ. Microbiol
12 A Comparison of Legionella and Other Bacteria Concentrations in Cooling Tower water /
[ Robert M. Capabianca;Neil B.Jrrinski;Joseph B. Juriski ] / Appl. Occup, Environ. Hyg.
13 Primary isolation media for legionnaries disease bacterium /
[ Feeley,J.C.;Gorman,G.W.;Weaver,R.E.;Mackel,D.C.;Smith,H.W. ] / J.Clin. Morcrobiol
14 Comparison of selective proedeures for isolation and enumeration of Legionella species from hot water system /
[ Leoni, P.P.Legani ] / Journal of Applied Microbiology   DOI   ScienceOn
15 서울시내 다중이용시설 냉각탑수의 레지오넬라균 분포 및 혈청학적특징(1994-1998) /
[ 박석기;황영옥;정지헌;정윤태 ] / 서울시보건환경연구원보
16 Legionnaires' disease: four summer's harvest /
[ Fraser,D.W. ] / Am. j. Med.   DOI   ScienceOn
17 Legionnaires' disease: Historical perspective /
[ Winn,W.R.Jr. ] / Clin. Mircrobiol, Rev.   DOI
18 /
[ Chanpin,E.S. ] / Himan Activity Patterns in the City : Things People do in Time and in Space
19 Legionella pecies, serogroups amd subgroups found in the environment in Singapore /
[ Meers P.D.;Goh K.T.;Lim E.W. ] / Ann Acad Med Singapore
20 Wcological Studies of Legionella species. I, Viable Counts of Legionella pneumophila in Cooling tower Water /
[ Massnari Ikedo;Eiko Yabuuchi ] / Microboio, Immunol   DOI
21 Isolaton of Legionella from water samples using various culture mothods /
[ Kusnetsov J.M.;Jousimies-Somer H.R.;Nevalainen A.l.;Martikainen P.J. ] / J Appl Bacteril   DOI
22 /
[ 식품의약청안전청 ] / 식품공전