The Validation of a Commercial Testosterone RIA Test Kits  

Ryu, Hwa-jin (Department of Nuclear Medicine, Seoul National University Hospital)
Shin, Seon-yeong (Department of Nuclear Medicine, Seoul National University Hospital)
Cho, Seong-uk (Department of Nuclear Medicine, Seoul National University Hospital)
Publication Information
The Korean Journal of Nuclear Medicine Technology / v.26, no.1, 2022 , pp. 38-41 More about this Journal
Abstract
Purpose Testosterone is a steroid hormone synthesized by the Leydig cells of the testes in men, and by the adrenal cortex and ovaries in women. Testosterone production is regulated by luteinzing hormone secreted by the anterior pituitary gland. In this experiment, the effectiveness of testosterone radioimmunoassay (RIA) kits produced by three companies was evaluated and compared in case the production of testosterone kits was stopped or supply problems occurred. Materials and Methods In October 2021, samples were collected from the patients (n=49) who requested the testosterone RIA test. The experiment was conducted by dividing the patient's sample into low concentration (1.0 ng/mL or less), medium concentration (2.0-4.0 ng/mL) and high concentration (6.0 ng/mL or more). The Testosterone RIA test compared and evaluated the validity of Company A kits used in this hospital and those of Company B and C used in other hospitals. The precision, sensitivity, recovery, linearity and correlation were evaluated for each kit. The testosterone RIA test was carried out in accordance with the insert kit manual for each manufacturer. Results As a result of measuring the precision of the intra assay, the Coefficient of Variation (CV) value of the company A kit was high at 11.4% only in the low concentration sample, and in the case of the company B and C kits, the CV value was less than 10% at low, medium, and high concentrations. In the inter-assay precision measurement, the CV value was less than 15% in both A and C kits, but in the case of the B kit, the CV value exceeded 15% at low and medium concentrations. Sensitivity was 0.13 ng/mL for company A, 0.01 ng/mL for company B, and 0.01 ng/mL for company C, and the linearity of all three kits showed excellent linearity. In the case of recovery rate, all of the A, B, and C company kits showed results that were out of 90-110%. In the case of correlation test, when compared with the company A kit currently use in here, the correlation coefficient (R2) value for the company B kit was 0.9508, and for the company C kit was 0.9352 Conclusion As a result, there was a slight difference in precision at the low concentration sample. The correlation test showed an excellent correlation coefficient. However, it was difficult to secure samples of various concentrations because there were not many tests of testosterone requested at this hospital. So, additional experiments should be carried out by acquiring samples of various concentrations on each laboratory later.
Keywords
Testosterone; Evaluation of efficacy; RIA(Radioimmunoassay);
Citations & Related Records
연도 인용수 순위
  • Reference
1 청구문화사, 핵의학 검사학, 2판, 청구문화사, 2013
2 서일택 외. 제 4판 임상핵의학 검사 기술학, 고려의학, 2010