Studies on sterile filters in the preparation of N-13 ammonia injection  

Oh, Chang Bum (Department of nuclear medicine, Samsung Medical Center)
Kim, Si Hwal (Department of nuclear medicine, Samsung Medical Center)
Cha, Min Jung (Department of nuclear medicine, Samsung Medical Center)
Shin, Jin (Department of nuclear medicine, Samsung Medical Center)
Ji, Yong Gi (Department of nuclear medicine, Samsung Medical Center)
Choi, Sung Ook (Department of nuclear medicine, Samsung Medical Center)
Publication Information
The Korean Journal of Nuclear Medicine Technology / v.23, no.1, 2019 , pp. 64-68 More about this Journal
Abstract
Purpose In the preparation process for N-13 Ammonia injections, there were radioactive medicines adsorbed on filters remarkably. Hereby, we have compared the adsorption rate and quality test on Millex GS filter and Satorious Minisart filter, both representatively hydrophilic sterilizing filters, also evaluated which filter is more accommodative for N-13 Ammonia injection. Materials and Methods The filters used for sterilization of N-13 Ammonia injections were Millex GS filter($0.22{\mu}m$) mand Satorious Minisart filter ($0.2{\mu}m$), which are generally used to strain aqueous solutions. After the N-13 Ammonia passes through each sterilization filter, the adsorption rate of the filter (n=10) is determined by measuring not only the radioactivity through the filter also the amount of radioactivity remaining in it using a Dose Calibrator. The N-13 Ammonia injections after each filter is tested by the quality control test to conform to the Samsung Medical Center standard. Results The ratio of radioactivity passed through Millex GS indicated $29.0{\pm}17.6%$. Satorious Minisart filters output was $80.9{\pm}3.2%$, respectively. Each ratio of radioactivity adsorbed on the sterile filter was $71.0{\pm}17.6%$ for Millex GS and $19.1{\pm}3.2%$ for the Satorious Minisart filters, respectively. Furthermore, on the ratio of filtered radioactivity, Using Satorious Minisart filter showed about 2.8 times higher than using Millex GS filter. The quality testing of N-13 Ammonia injections through each filter met the Samsung Medical Center standard. Conclusion The Millex GS filter is composed of cellulose acetate and cellulose nitrate, whereas the Satorious Minisart filter if composed only of cellulose acetate. Therefore, the presence of cellulose nitrate in the membrane seems to have made differences. Therefore, the use of Satorious Minisart filter in the preparation of N-13 Ammonia injection solution minimized the loss of radioactive medicines due to filter adsorption, thereby improving the synthesis yield.
Keywords
N-13 ammonia; sterile filter; CAD;
Citations & Related Records
연도 인용수 순위
  • Reference
1 공은정 외 관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교. Nucl Med Mol Imaging Vol. 42, No. 5, Oct 2008.
2 Firas Al Badarin et al Assessment of myocardial blood flow and coronary flow reserve with positron emission tomography in ischemic heart disease : current state and future directions Heart Fail Rev (2017) 22:441-453.   DOI
3 Thorsten M. Leucker et al Positron emission Tomography- Determined Hyperemic Flow, Myocardial Flow Reserve, and Flow Gradient-Quo vadis? Front Cardiovasc Med. 2017 Jul.
4 Aydinbelge FN et al Current status of myocardial perfusion imaging radiopharmaceuticals for SPECT and PET imaging modalities. Int J Res Med Sci. 2017 Jan;5(1):1-7   DOI
5 안현호 외 [$^{11}C$]PIB 제조 수율 증진을 위한 다양한 멸균필터의 적용 및 비교. J Nucl Med. (2016).
6 지용기 외 Lymphoscintigraphy에서 방사성의약품의 Filter 선택에 관한 연구. J Nuc Med Technol.