Browse > Article

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT'  

Kim, Jaeil (Dept. of Nuclear Medicine, Seoul National Univ. Hospital)
Lim, Jeongjin (Dept. of Nuclear Medicine, Seoul National Univ. Hospital)
Cho, Seongwook (Dept. of Nuclear Medicine, Seoul National Univ. Hospital)
Noh, Kyeongwoon (Dept. of Nuclear Medicine, Seoul National Univ. Hospital)
Publication Information
The Korean Journal of Nuclear Medicine Technology / v.23, no.1, 2019 , pp. 54-58 More about this Journal
Abstract
Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.
Keywords
focus type SPECT; spatial resolution; sensitivity; spatial uniformity;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Yeong Kwak Ban. Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study. KSNMT. 2016;2:49-53.
2 Brian Hutton, Performance evaluation of D-SPECT - a novel dedicated cardiac SPECT scanner. J Nucl Med. 2008; 49:124.
3 SPECTRUM, D-SPECT user manual
4 Jun Key Jung Nuclear Medicine. Korea Medical Book Publisher Co.