Browse > Article
http://dx.doi.org/10.5573/ieek.2013.50.12.270

3-Axis Static Magnetic Field Cancellation System  

Kim, Soochan (Dept. of Electrical and Electronic Engineering, Institute for IT Convergence, Hankyong National University)
Publication Information
Journal of the Institute of Electronics and Information Engineers / v.50, no.12, 2013 , pp. 270-276 More about this Journal
Abstract
We have been unwittingly exposed to magnetic field. Biological effects due to electromagnetic field exposure has been studied over the past several decades. There has been epidemiological studies and laboratory studies. In the case of laboratory studies, the effect has been observed through the cell stimulation of an artificial magnetic field. The used frequency and waveform are various in the cell experiment, but the intensity of the magnetic field is usually around 10G. Intensity of Earth's magnetic field is about 300-400mG. Although this intensity is not much higher than artificial magnetic field as 3-4% amplitude, we can't ignore the effect because every living thing on earth has already adapted for long time ago. In this study, we have designed and implemented the 3-axis magnetic field generation system in oder to remove the static magnetic field in the real-time and kept its intensity less than ${\pm}5mG({\pm}0.5uT)$ using 3-axis helmholtz coil.
Keywords
Magnetic field; Geomanetism; Cancellation; Real-time; Biological effect;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 http://en.wikipedia.org/wiki/Earth's_magnetic_field
2 T. Yamazaki and H. Oda, "Orbital influence on Earth's magnetic field: 100,000-year periodicity in inclination," Science, vol. 295, pp. 2435-2438, 2002.   DOI   ScienceOn
3 Y. S. Ryu, M. Y. Kim, and Y. G You, "Orientation Tracking Method based on Angular Displacement for Wireless Capsule Endoscope," Journal of the Korea Contents Association, vol. 8(2), pp. 27-32, 2008.   과학기술학회마을   DOI   ScienceOn
4 C. Constable, "Geomagnetic Temporal Spectrum," The Encyclopedia of Geomagnetism and Paleomagnetism, 2005.
5 K. Hansson Mild and M.-O. Mattsson, "ELF Noise Fields: A Review," Electromagnetic Biology and Medicine, vol. 29, pp. 72-97, 2010.   DOI   ScienceOn
6 B. C. Woo, and et al, "Construction of an Earth's Field Compensation System for the Measurement of.Proton Gyromagnetic Ratio", Journal of Koran Magnetics Society, Vol. 2(2), pp. 156-162, 1992.
7 J. H. Kim and Y. M, Gimm, "Design of a Magnetic Field Source for In Vivo Experiments at Extremely Low Frequency," The Jornal of Korean Institute of Electromagnetic Engineering and Science, vol. 14, pp. 871-877, 2003.
8 J. H. Kwon, et al., "Helmholtz Coil System for Measuring Magnetic Shielding Effectiveness," The proceeding of Korean Institute of Communication and Information Sciences, vol. 21, pp. 368-371, 1998
9 K. C. Nam, S. C. Kim, and D. W. Kim, "Development of an ELF(extremely low frequency) EMF(electromagnetic field) Generator", The Jornal of Korean Institute of Electromagnetic Engineering and Science, vol. 12(2), pp. 98-104, 2001
10 S. R. Gyawali, "Design and construction of Helmholtz coil for biomagnetic studies on soybean," University of Missouri--Columbia, 2008.
11 K. Tashiro, H. Wakiwaka, K. Matsumura, and K. Okano, "Desktop Magnetic Shielding System for the Calibration of High-Sensitivity Magnetometers," Magnetics, IEEE Transactions on, vol. 47, pp. 4270-4273, 2011.   DOI   ScienceOn
12 http://diyaudioprojects.com/Technical/American-Wire-Gauge/
13 http://www.trifield.com/content/dc-milligaussmeter-3-axis/