Development of a Hydrogen Peroxide Sensor Based on Palladium and Copper Electroplated Laser Induced Graphene Electrode  

Park, Daehan (Dept. of Electrical and Electronic Engineering, Korea University)
Han, Ji-Hoon (Dept. of Electrical and Electronic Engineering, Korea University)
Kim, Taeheon (Dept. of Electrical and Electronic Engineering, Korea University)
Pak, Jungho (Dept. of Electrical and Electronic Engineering, Korea University)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.67, no.12, 2018 , pp. 1626-1632 More about this Journal
Abstract
In this paper, we describe the fabrication and characterization of a hydrogen peroxide ($H_2O_2$) sensor based on palladium and copper (PdCu) electroplated laser induced graphene (LIG) electrodes. $CO_2$ laser was used to form LIG electrodes on a PI film. This fabrication method allows simple control of the LIG electrode size and shape. The PdCu was electrochemically deposited on the LIG electrodes to improve the electrocatalytic reaction with $H_2O_2$. The electrochemical performance of this sensor was evaluated in terms of selectivity, sensitivity, and linearity. The physical characterization of this sensor was conducted using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), which confirmed that PdCu was formed on the laser induced graphene electrode. In order to increase the sensor sensitivity, the Pd:Cu ratio of the electroplated PdCu was varied to five different values and the condition of highest amperometric current at an identical of $H_2O_2$ concentration was chosen among them. The resulting amperometric current was highest when the ratio of Pd:Cu was 7:3 and this Pd;Cu ratio was employed in the sensor fabrication. The fabricated PdCu/LIG electrode based $H_2O_2$ sensor exhibited a sensitivity of $139.4{\mu}A/mM{\cdot}cm^2$, a broad linear range between 0 mM and 16 mM of $H_2O_2$ concentrations at applied potential of -0.15 V, and high reproducibility (RSD = 2.6%). The selectivity of the fabricated sensors was also evaluated by applying ascorbic acid, glucose, and lactose separately onto the sensor in order to see if the sensor ourput is affected by one of them and the sensor output was not affected. In conclusion, the proposed PdCu/LIG electrode based $H_2O_2$ sensor seems to be suitable $H_2O_2$ sensor in various applications.
Keywords
Laser induced graphene; Palladium; Copper; Hydrogen peroxide;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 R. Majidi, "A biosensor for hydrogen peroxide detection based on electronicproperties of carbon nanotubes", Molecular Physics, vol. 111, no. 1, pp. 89-93, 2013.   DOI
2 M. Rajkumar, S. Thiagarajan, S.-M. Chen, "Electrochemical fabrication of Rh-Pd particles and electrocatalytic applications", Journal of Applied Electrochemistry, vol. 41, no. 6, pp. 663-668, 2011.   DOI
3 Chen, X., Wu, G., Cai, Z., Oyama, M., & Chen, X. "Advances in enzyme-free electro- chemical sensors for hydrogen peroxide, glucose, and uric acid", Microchimica Acta, vol. 181, no. 7, pp. 689-705, 2014.   DOI
4 Zhang, Z., Gu, S., Ding, Y., & Jin, J. "A novel nonenzymatic sensor based on $LaNi_{0.6}Co_{0.4}O_3$ modified electrode for hydrogen peroxide and glucose", Anal.Chim. Acta, vol. 745, pp. 112-117, 2012.   DOI
5 Meng, F., Yan, X., Liu, J., Gu, J., & Zou, Z. "Nanoporous gold as non-enzymatic sensor for hydrogen peroxide" Electrochimica Acta, vol. 56, no. 12, pp. 4657-4662, 2011.   DOI
6 Miscoria, S. A., Barrera, G. D., & Rivas, G. A. "Analytical performance of a glucose biosensor prepared by immobilization of glucose oxidase and different metals into a carbon paste electrode" Electro-analysis An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis, vol. 14, no. 14, pp. 981-987, 2002.
7 Luque, G. L., Ferreyra, N. F., & Rivas, G. A. "Glucose biosensor based on the use of a carbon nanotube paste electrode modified with metallic particles" Microchimica Acta, vol. 152, no. 3-4, pp. 277-283, 2006.   DOI
8 Hsieh, M. W., & Whang, T. J. "Electro- deposition of PdCu alloy and its application in methanol electrooxidation" Applied Surface Science vol. 270, pp. 252-259, 2013.   DOI
9 Miao, Y. E., He, S., Zhong, Y., Yang, Z., Tjiu, W. W., & Liu, T. "A novel hydrogen peroxide sensor based on $Ag/SnO_2$ composite nanotubes by electro-spinning", Electrochimica Acta, vol. 99, no. 1, pp. 117-123, 2013.   DOI
10 Chen, K. J., Pillai, K. C., Rick, J., Pan, C. J., Wang, S. H., Liu, C. C., & Hwang, B. J. "Bimetallic PtM (M= Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for $H_2O_2$" Biosensors and Bioelectronics, vol. 33, no. 1, pp. 120-127, 2012.   DOI
11 Liu, A., Geng, H., Xu, C., & Qiu, H. "A three-dimensional hierarchical nanoporous PdCu alloy for enhanced electrocatalysis and biosensing", Analytica chimica acta, vol. 703, no. 2 pp. 172-178, 2011.
12 Lin, J., Peng, Z., Liu, Y., Ruiz-Zepeda, F., Ye, R., Samuel, E. L., & Tour, J. M. "Laser-induced porous graphene films from commercial polymers", Nature communications, vol. 5, no. 5714, 2014.
13 Kim, G. J., Kim, T., & Pak, J. "Development of flexible glucose measurement sensor based on copper nanocube electroplated laser induced graphene electrode", The Korean Institute of Electrical Engineers, vol. 67, no. 3, pp. 413-418, 2018.
14 Ensafi, A. A., Abarghoui, M. M., & Rezaei, B. "Electrochemical determination of hydrogen peroxide using copper/porous silicon based non-enzymatic sensor", Sensors and Actuators B: Chemical, vol. 196, pp. 398-405, 2014.   DOI
15 JJanyasupab, M., Liu, C. W., Zhang, Y., Wang, K. W., & Liu, C. C. "Bimetallic Pt-M (M= Cu, Ni, Pd, and Rh) nanoporous for $H_2O_2$ based amperometric biosensors", Sensors and Actuators B: Chemical, vol. 179, no. 209-214, 2013.   DOI
16 J. V. B. Kozan, Silva, R. D., Serrano, S. H. P., Lima, A. W. O., & Angnes, L. "Biosensing hydrogen peroxide utilizing carbon paste electrodes containing peroxidases naturallyimmobilized on coconut (Cocus nucifera L.) fibers", Analytica Chimica Acta, vol. 591, no. 2, pp. 200-207, 2007.   DOI
17 Nandini, S., Nalini, S., Manjunatha, R., Shanmugam, S., Melo, J. S., & Suresh, G. S. "Electrochemical biosensor for the selective determination of hydrogen peroxide based on the co-deposition of palladium, horseradish peroxidase on functionalized-graphene modified graphite electrode as composite", Journal of Electroanalytical Chemistry, vol. 689, pp. 233-242, 2013.   DOI
18 Anzai, J. I., Takeshita, H., Kobayashi, Y., Osa, T., & Hoshi, T. "Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: elimination of ascorbate interference by means of an ascorbate oxidase multilayer", Analytical chemistry, vol. 70, no. 4, pp. 811-817, 1998.   DOI
19 Liu, H., Weng, L., & Yang, C. "A review on nanomaterial-based electrochemical sensors for $H_2O_2,\;H_2S$ and NO inside cells or released by cells", Microchimica Acta, vol. 184, no. 5, pp. 1267-1283, 2017.   DOI
20 Wei-Wei, W. A. N. G., Yu, Q. I. U., ZHANG, S. P., Jia-Wei, L. I., Xiao-Quan, L. U., & Xiu-Hui, L. I. U. "A hydrogen peroxide sensor based on Pt@Au nanoparticles loading to polyethyleneimine functionalized carbon nanotubes", Chinese Journal of Analytical Chemistry, vol. 42, no. 6, pp. 835-841, 2014.   DOI