Browse > Article
http://dx.doi.org/10.5370/KIEE.2014.63.2.230

Analysis on Voltage Sag According to Impedance and Application Location of SFCL with Recloser-Recloser Coordination  

Kim, Yi-Gwan (Dept. of Electrical Engineering at Soongsil University)
Noh, Shin-Eui (Dept. of Electrical Engineering at Soongsil University)
Kim, Jin-Seok (Dept. of Electrical Engineering at Soongsil University)
Kim, Jae-Chul (Dept. of Electrical Engineering at Soongsil University)
Lim, Sung-Hun (Dept. of Electrical Engineering at Soongsil University)
Kim, Hye-Rim (KEPCO Research Institute)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.63, no.2, 2014 , pp. 230-236 More about this Journal
Abstract
Superconducting fault current limiter (SFCL) has been expected as one of more effective solutions for decreasing fault current instantaneously and various types of SFCLs have been developed to apply into real power system. Recently, the application of the SFCL in a power distribution system has been reported to be contributed to the suppression of the voltage sag as well as the limitation of the fault current. However, the suppressing effect of voltage sag by the SFCL depends on component of its impedance and its application location in a power distribution system considering the recloser-recloser coordination. This paper analyzed the voltage sag caused by recloser-recloser coordination in a power distribution system and the suppression of the voltage sag due to the application location of the SFCL in a power distribution system was discussed through the PSCAD/EMTDC simulation.
Keywords
Superconducting fault current limiter (SFCL); Recloser-recloser coordination; Voltage sag;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 J.-H. Kim, K.-W. Lee, "Increasement of Fault Current and the Plan for Reaction in Power System", Journal of electrical world, pp. 19-31, 1998.
2 M. E. Almeida, C. S. Rocha, J. A. Dente, and P. J. Costa Branco, "Enhancement of power system transient stability and power quality using superconducting fault current limiters," in Powereng 2009, Lisbon, Portugal, Mar. 18-20, 2009.
3 J.-S. Kim, S.-H. Lim, and J.-F. Moon et al., "Analysis on the protective coordination on neutral line of main transformer in power distribution substation with superconducting fault current limiter," The Trans. on the Korean Institute of Electrical Engineers, vol. 58, no. 11, pp. 2089-2094, Nov. 2009.   과학기술학회마을
4 J.-S. Kim, S.-H. Lim and J.-C. Kim, "Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations," Journal of Electrical Engineering & Technology vol. 7, no. 5, pp. 659-663, 2012.   DOI   ScienceOn
5 D.-S., Hyun , "The Study of Development of Series Connected Dynamic Voltage Resorer for Power Quality and Utilization", Ministry of commerce, 2003.
6 K.-B. Jung, "Regulation of Power quality in the Centralized Power Systems", The journal of KIPE, Vol. 10, No. 6, pp. 26-32, 2005.
7 B.-M. Han, "Distributed Power and Power Quality Compensate", Ye-gi, 2012.
8 IEEE 1159, 1995.
9 S.-H. Lim, "Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element", Journal of KIEE, Vol. 24, No. 1, pp. 112-116, 2010.   과학기술학회마을   DOI   ScienceOn