Study of the Wearable Electrocardiogram Measuring System using Capacitive-coupled Electrode |
Lee, Jae-Ho
(Biomedical Engineering, Konkuk University)
Lee, Young-Jae (Biomedical Engineering, Konkuk University) Lee, Kang-Hwi (Biomedical Engineering, Konkuk University) Kang, Seng-Jin (Biomedical Engineering, Konkuk University) Kim, Kyeung-Nam (Biomedical Engineering, Konkuk University) Park, Hee-Jung (Biomedical Engineering, Konkuk University) Lee, Jeong-Whan (Dept. of Biomedical Engineering, Konkuk University) |
1 | E. Huigen, A. Peper, and C. A. Grimbergen, "Investigation into the origin of the noise of surface electrodes," Med. Biological. Eng. Comput., vol. 40, no. 3, p. 32-38, 2002. |
2 | M. Spach, R. Bar, J. Havstad, and E. Long, "Skin-electrode impedanceand its efect on recording cardiac potentials," Circulation, vol. 34, p. 649-656, 1996. |
3 | T. Maruyama, M. Makikawa, "ECG Measurement Using Capacitive Coupling Electrodes for Man-Machine Emotional Communication," 207 IEEE/ICME International Conference on Complex Medical Enginering, p.378-383, 2007. |
4 | J. Alihanka and K. Vaahtoranta, "A static charge sensitive bed. A new method for recording body movements during slep," Electroencephalogr. Clin Neurophysiol., vol. 46, p. 731-4, 1979. DOI ScienceOn |
5 | T. Tamura, T. Togawa, M. Ogawa, and M. Yoda, "Fuly automated health monitoring system in the home," Med. Eng. Phys., vol. 20, p. 573-9, 1998. DOI ScienceOn |
6 | K. Watanabe, T. Watanabe, H. Watanabe, H. Ando, T. Ishikawa, and K. Kobayashi, "Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method," IEEE Trans. BIOMEDICAL ENGINEERING. |
7 | Ronald W. Schafer, "What Is a Savitzky-Golay Filter?," IEEE SIGNAL PROCESSING MAGAZINE, p.11-17, July 2001. |
8 | M. Ishijima, "Monitoring of electrocardiograms in bed without utilzing body surface electrodes," IEEE Trans. Biomed. Eng., vol. 40, p. 593-4, 1993. DOI ScienceOn |
9 | Alihanka and K. Vahtoranta, "A static charge sensitive bed. A new method for recording body movements during slep," Electroencephalogr. Clin Neurophysiol., vol. 46, p. 731-4, 1979. DOI ScienceOn |
10 | Byungchae Le, Geon Hahm, Youngil Jun, Kwangchol Choi, Keunho Choi, Wonky Kim, Junso Kim, Kisam Jeong, Jeongwhan Le, Myoungho Le, George wright, David Cochlan, "Development of a 12 Chanel Interpretive Electrocardiograph," The Korean Society of Medical Biological and Enginering, no.1, p.41-414, 1997. |
11 | G. Cliford, F. Azuaje, P. McShary, "Advanced methods and tols for ECG data analysis," Norwood, 2006 |
12 | A. Searle and L. Kirkup, "A direct comparison of wet, dry and insulatingbioelectric recording electrodes," Physiological Measure, vol.21, no. 2, p. 271, 2000. DOI ScienceOn |
13 | T. Tamura, T. Togawa, M. Ogawa, and M. Yoda, "Fuly automated health monitoring system in the home," Med. Eng. Phys., vol. 20, p. 573-9, 1998. DOI ScienceOn |
14 | Ha-Chul Jung, Jin-He Mon, Dong-Hyun Baek, Jae-He Le, Yon-Young Choi, Joung-Sok Hong, "CNT/PDMS Composite Flexible Dry Electrodes for Long-Term ECG Monitoring," IEEE Trans. Biomed. Eng., vol. 59, NO. 5, MAY 2012. |