Single-Phase Power Factor Correction AC/DC Converter with Short-term Interruption Tolerance  

Lee, Dong-Su (Dept. of Electronic Engineering, Pukyong Nat'l Univ.)
Lee, Wang-Geun (Power Electronics Research Center)
Jeon, Seong-Jeub (Dept. of Electronic Engineering, Pukyong Nat'l Univ.)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.62, no.8, 2013 , pp. 1090-1094 More about this Journal
Abstract
In this paper, a method to cope with short-term interruption is proposed. The proposed method uses a capacitor bank consisting of supercapacitors. A supercapacitor is a good means for energy storage for short-term usage. The proposed circuit is simple and accordingly easy to construct and to control. A prototype of 360 W single-phase PFC ac-dc converter is constructed and experimental results are presented.
Keywords
Power factor correction; Interruption; Energy storage; Super capacitor;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 M.H.J. Bollen, Understanding Power Quality Problems, IEEE Press, 2000.
2 R.E. Cosse, D.G. Dunn, and R.M. Spiewak, "Is My UPS Distribution System Coordinated?", IEEE Trans. on Industry Applications, vol. 42, no. 6, pp. 1565-1573, Nov. 2006.   DOI   ScienceOn
3 B. Yang, P. Xu and F. C. Lee, "Range Winding for Wide Input Range Front End DC/DC Converter", Proc. IEEE Applied Power Electronics Conference, pp. 476-479, 2001.
4 Y. Xing, L. Huang, X. Cai and S. Sun "A Combined Front-end Converter", Proc. IEEE APEC, pp. 1095- 1099, 2003.
5 Y. Jang, M. M. Jovanovic and D. L. Dillman, "Hold-up Time Extension Circuit with Integrated Magnetics", IEEE Trans. on Power Electronics, vol. 21, no. 2, pp. 394-400, Mar. 2006.   DOI   ScienceOn
6 Y. Yuan, L. Chang, and P. Song, "A New Front-end Converter with Extended Hold-up Time", Proc. 2007 Conference on Large Engineering System, pp. 275-278, 2007.
7 D.Y. Kim, Y.D. Kim, K.M. Cho and G.W. Moon, " Adaptive Link Capacitor Voltage Variation Control Method for Server Power Supply", Proc. IPEMC 2009, pp. 1-5, 2009.
8 Y.-D. Kim, K.-M. Cho and G.-W. Moon, "Hold up time extension technique for high efficiency, high power density server power supply", Trans. of KIPE, vol. 15, no. 2, pp. 96-102, Mar. 2010   과학기술학회마을   DOI   ScienceOn
9 W.-G. Lee, Y.-J. Jeong and S.-J. Jeon, "Power Factor correction AC/DC converter with short-term blackout tolerance", Proc. of 40th KIEE Summer Conference 2009, pp. 925-926, 2009