Browse > Article

Development of In-Flex System using the Flexibility Aluminum Clad Cable  

Jung, Soon-Won (ETRI 융합부품.소재연구부문 Post-Doc)
Koo, Kyung-Wan (호서대학교 국방과학기술학과)
Publication Information
The Transactions of the Korean Institute of Electrical Engineers P / v.58, no.2, 2009 , pp. 178-183 More about this Journal
Abstract
The developed in-flex system completed the wiring work with the plug-in connection. To maintain electrical and mechanical stability, and an insulation between the conductors was strengthened by forming a partition. Moreover, the error according to a bad connection was prevented by separating the inlet from the outlet of the electric trace and thus the quick construction become possible. The metal reinforcing material was added outside the upper case and lower case. The fire-resistance efficiency was maximized in order to minimize a damage by the fire. As to the developed system, we found that it takes shorter time to complete installation than the rigid steel conduit wiring work, and that about 25 % of construction cost was saved because the labor costs decrease due to the shorter construction period of time.
Keywords
Cross; Extender; Fixture; Flexibility Aluminum Clad Cable; In-Flex System; Reducer; Starter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 T. Ashment, "Designing high-reliability wiring systems with modular composite rectangular connectors", Connector Specifier, Vol. 4, Iss. 12, pp. 17-18, 1988
2 V. Hoffmann, H. Rudolph, "Modular automotive wiring systems", VDI Berichte, Iss. 1789, pp. 579-591, 2003
3 A. Gibson, "Emerging applications for copper-clad steel and aluminum wire", Wire Journal International, Vol. 41, Iss. 2, pp. 142-148, 2008   ScienceOn
4 Y. Li, X. Zhao, Y. Li, "Vision-based detection of weld pool width in TIG welding of copper-clad aluminum cable", China Welding (English Edition), Vol. 16, Iss, 3, pp. 27-31, 2007   ScienceOn
5 N. Chow, "In-line cleaning of steel core wire for the manufacture of aluminum clad steel wire", Wire Journal International, Vol. 35, Iss. 2, pp. 104-109, 2002   ScienceOn
6 S. C. Roberts, R. L. Evans, "Preparation of shielded metal clad cables for sealing in classified locations", Record of Conference Papers - Annual Petroleum and Chemical Industry Conference, pp. 219-225, 1988
7 H. Kanithi, D. Phillips, C. King, B. Zeitlin, "Development and characterization of aluminum clad superconductors", IEEE Transactions of Magnetics, Vol. 24, Iss. 2. pp. 1029-1032, 1987   DOI   ScienceOn
8 L. O. Hoeft, B.Bergsrud, E. W. Tokarsky, "Measured surface transfer impedance of braided cable shields made from metal clad aramid yarn blended with metal wires", IEEE International Symposium on Electromagnetic Compatibility, Vol. 2, pp. 887-890, 2000