A Study on the PD Signal Analysis with Applied Fuzzy Algorithm  

Kim, Yong-K. (원광대학 전기전자 및 정보공학부)
Kim, Jin-Su (원광대학 전자재료공학과)
Publication Information
The Transactions of the Korean Institute of Electrical Engineers C / v.55, no.4, 2006 , pp. 166-171 More about this Journal
Abstract
In this paper, we have studied for analysis of the partial discharge(PD) signal in underground transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with fuzzy algorithm. In our algorithm, we developed system configuration that detected accumulating PD signal using by Labview and programmed fuzzy algorithm can be analyzed the PD signal using with Matlab. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 50kV setup has generated and then has applied with $15k{\sim}17kV$ with 1:1 time probe. It's also used the LDPE 0.27mmt (scratch error 0.05mmt) to sample for making PD. In conclusion, Our new class of PD detected algorithm has also compared with previous PRPDA or Fuzzy algorithm. which has diagnose more conveniently by adding numerical values.
Keywords
Partial Discharge(PD); Fuzzy; Labview;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Y. S. Lim and J. Y. Koo 'Comparative Analysis of Partial Discharge Patterns form Different Artificial Defects by Means of Conventional Phase-Resolved Partial Discharge Analysis and a Novel Chaotic Analysis of Partial Discharge' Journal of the Korean Physical Society, Vol. 42, No.6, pp. 755-764, June 2003
2 오성권 '프로그래밍에 의한 컴퓨터지능' 내하출판사, pp.7-222, 2002
3 Jeon-Seon Lee and Ja-Yoon Koo, 'An Analysis of the artial Discharge Pattern Related to the Artificial Defects Introduced at the Interface in an XLPE Cable Joint using a Laboratory Model' KIEE international Transactions on EA, Vol. 2-C, No.5, pp. 239-245, 2002   과학기술학회마을
4 이전선 'HFPD 부분방전 검출을 이용한 XLPE 전력 케이블 시스템 진단 기술 개발 연구', 한양대학교 박사 학위 논문, 2003
5 김경화, 이동준, 곽희로, 'GIS내 파티클의 상태에 따른 부분방전 신호의 분석' Journal of the Korean Institute of llluminating and Electrical Installation Engineers, Vol. 14, No.1, pp, 67-74, January 2000   과학기술학회마을
6 Kai Wu, Toshiro Ijichi, Akira Kojima, Fumitaka Komori, Yasuo Suzuoki, 'Influence of PD rest time on \varphi-q-n patterns from voids' IEEE 7th International Conference on solid Dielectrics, pp. 93-96, June 2001   DOI
7 김종서, 이은석, 천종철, '신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석' 전기전자재료학회논문지, Vol. 16, No. 12S, pp. 93-96, June 2001   과학기술학회마을   DOI
8 Toshihiro Takahashi, Tatsuji Yamada, Naoki Hayakawa, and Hitoshi Okubo, 'Space Charge Behavi or in SF6 Gas and Sequential Generation of PD Pulses' IEEE Transaction on Dielectrics and Electrical Insulation, Vol. 7, No.1, pp. 141-145, February 2000   DOI   ScienceOn
9 Kang-Won Lee, Dong-Uk jang, Iae-Yeol Park, Seong-Hwa Kang, and Kee- Joe Lim 'Artificial Neural Network Discrimination of Multi-PD Sources Detected by UHF Sensor' KIEE International Transactions on EA, VoJ. 3C, No. I, pp. 5-9, 2003   과학기술학회마을
10 F.H.Kreuger 'Partial Discharge Detection in High-Voltage Equipment' Butterworth, pp. 1-152, 1989
11 소순열, 홍견진, 정우성, 임장섭, 이진, 이준웅, 김태성, '전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석' 전기전자재료학회논문지, Vol. 11, No. 11, pp. 1035-1042, November 1998   과학기술학회마을