This paper analysed the characteristics of current density induced inside human body by 60 Hz extremely low frequency magnetic fields according to varying conductivities of human model. Human model was composed of several organs and other parts, whose shapes were expressed by spheroids or cylinders. Organs such as the brain, heart, lungs, liver and intestines were taken into account. Applying the boundary element method to the human model, we estimated effects on the induced current distribution due to differences of the organ conductivity and shape. We find organ conductivity influences most and a cross section area and a position of organ also gives effects.
Keywords
Induced Current Density; Extremely Low Frequency Magnetic Field; Human Model; Organ Conductivity;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 T.W. Dawson, K. Caputa, M.A. Stuchly,'Influence of Human model resolution on Computed Currents Induced in Organs by 60Hz Magnetic Fields', Bioelectromagnetics, Vol. 18, pp. 478-490, 1997   DOI   ScienceOn
2 O.P. Gandhi, J.Y. Chen,'Numerical Dosimetry at Power Line Frequencies Using Anatomically Based Models', Bioelectromagntics Supplement 1, pp. 43-60, 1992   DOI   ScienceOn
3 NRPB,'Restrictions on Human Exposure to Static and Time Varying Electromagnetic Fields and Radiation', Documents of the NRPB 4, 5, pp1-69, 1993
4 ACGIH,'Documentation of the Threshold Limit Values for Physical Agents in the Work Environment', Cincinnati, Ohio, 1998
5 CENELEC,'Human Exposure to Electromagnetic Fields(0Hz to 10kHz)', CENELEC Std. ENV 50166-1, 1995
6 O. Bottauscio, R. Conti,'Magnetically and Electrically Induced Currents in Human body models by ELF Electromagnetic Fields', Proc. of 10th ISH Vol. 5-8, 1997
7 민석원, '유전율 및 도전율을 고려한 765kV 송전선하의 인체 유도 전계해석', 대한전기학회 논문지, 6호, 제49권, pp. 341-345, 2000   과학기술학회마을
8 민석원, 송기현, 양광호, 주문노, '유전율 및 도전율을 고려한 765kV 송전선하의 전계에 의한 인체내부 유도 전류밀도 해석', 대한전기학회 논문지, 8호, 54A, pp. 461-465, 2004   과학기술학회마을
9 IRPA/INIRC,'Interim Guidelines on Limits of Exposure to 50/60Hz Electric and Magnetic Fields', Health Physics, 58, 11, pp. 113-122, 1990
10 DIN/VDE,'Safety at Electromagnetic Fields: Limits of Field Strengths for Protection of Persons in Frequency Range from 0 to 30kHz', DIN/VDE 0848-4/A3, 1995
11 S.W. Min, J.B. Kim, D.I. Lee,'A Study on Corona Characteristics of Symmetric and Asymmetric Conductor Bundle for 765kV Double Circuit Transmission Line by the Use of Corona Cge', Proc. of 8th ISH, Vol.3, pp. 457-460, 1993
12 S.W. Min, J.K. Park, J.B. Kim,'Conductor Bundle Geometry Optimization in view of Conductor Surface Gradient', IEE Japan, vol. 111-B, pp. 1065-1072, 1991
13 T.Takuma, T.Kawamoto,'A Very Stable Calculation Method for Ion Flow Field of HVDC Transmission Lines', IEEE Trans. on Power Delivery, Vol. PWRD-2, No.1, pp. 189-198, 1987
14 민석원, 김응식, 명성호, 이병윤, 박종근, '765kV 교류 2 회선 송전선하의 인체 및 자동차에 유도되는 전압, 전류 계산', 대한 전기학회 논문지, 5호, 제 45권, pp. 301-309, 1996