Browse > Article

A Study on Characteristics of Sagnac Interferometric Optical Fiber Sensor to Pulsed Ultrasonic Signal in Underwater  

이준호 (호서대 전기정보통신공학부)
신대용 (호서대 전기정보통신공학부)
Publication Information
The Transactions of the Korean Institute of Electrical Engineers C / v.53, no.1, 2004 , pp. 15-19 More about this Journal
Abstract
In this paper, we present the fabrication and characteristic analysis of Sagnac interferometric optical fiber senior(OFS) system for detecting pulsed ultrasonic signal in underwater. The hollow cylindrical mandrel wound round by single mode optical fiber is used as sensing component. The ultrasonic signal source is simulated by the PZT actuator operated by an function generator. The distance dependency of the OFS's sensitivity was measured. The sensitivity has been shown to be inversely propotional to the square-root of distance between ultrasonic source and sensing component. It has also been shown that the OFS could detect the signals less affected by ultrasonic path comparing to conventional acousto-electric sensor. and accurate location of ultrasonic signal could be carried out using two OFSs.
Keywords
Sagnac interferometer; optical fiber sensor(OFS); PZT; partial discharge(PD);
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 /
[ Donald E. Hall ] / Basic Acoustics
2 이종길, 윤형규, 서인창, '끝단이 막힌 중공 원통형 광섬유 하이드로폰의 감도 해석' 한국소음진동학회지, 6권, 4호, p. 475, 1996   과학기술학회마을
3 Donald E. Hall, 'Basic Acoustics', John Wiley & Sons, Inc., p. 10, 1987   과학기술학회마을
4 Abbas Zsrgari, Trevor R.Blackburn, 'Modified Optical Fiber Sensor for PD Detection in High Voltage Power Equipment', Conf. Record of the 1996 IEEE ISEI, pp.424-427
5 ZhaoZhiqiang, Mark MacAlpine, M.Suleyman Demokan, 'The Directionality of an Optical Fiber High Frequency Acoustic Sensor for Partial Discharge Detection and Location', Journal of Lightwave Technology, Vol.18, No.6,2000, pp.795-806   DOI   ScienceOn
6 Peter Hauptmann, 'Sensors Principles and Appliations'
7 이종길, 이준호, 김상준, '광섬유 Sagnac 간섭계를 이용한 유중방전 신호검출', Trans. KIEE, Vol.49C, No.11. 2000, pp.622-626   과학기술학회마을
8 Mark MacAlpine, ZhaoZhiqiang, M.Suleyman Demokan, 'Development of a fibre-optic sensor for partial discharges in oil-filled power transformers', Electric Power System Research 63, pp.27-36, 2002.Hee-ro Kwak, Jae-Chul Kim, Sun-Ju Hwang, 'Detection and Location of Partial Discharge in Transfermers.' Journal of KIEE, pp. 295-301, 1992   DOI   ScienceOn
9 신대용, 권기태, 이종길, 이준호, '수중에서 Sagnac 간섭계를 이용한 광섬유 센서의 지향성에 관한 연구', 대한전기학회 하계학술대회 논문집(C), p. 1714, 2002
10 김상준, '광섬유 Sagnac 간섭계를 이용한 방전현상 검출', 고려대학교 박사 논문, 2000
11 이종길, 박윤석, 이준호, '광섬유 간섭계 센서를 이용한 부분방전 음압 측정', 한국음향학회지, 21권, 7호, p. 614, 2002   과학기술학회마을