Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration |
Park, Jeong-Sook
(College of Nursing, Keimyung University)
Oh, Hyae-Ryeung (College of Nursing, Keimyung University) Seo, Bo-Hyae (College of Nursing, Keimyung University) Bhang, Jung-Hee (College of Nursing, Keimyung University) |
1 | Carbone-Traber, K. B., Shank. C. A. (1986). Glass partic.e contamination in single dose ampules. Anesth Analg, 65, 1361-1363 |
2 | Furgang, F. A. (1974). Glass particles in ampules. Anesthesiology, 41(5), 525 |
3 | Shim, C. K., Han, Y. H., & Kwon, D. S. (1991). Comparative study of particulate contamination form ampoule and prefilled syringe. J Korean Pharm Sci, 21(3), 155-160 과학기술학회마을 |
4 | Song, I. J .(2004). Historical perspective and future direction for intravenous injectable drug dispensing in the seoul national university hospital. J Korean Soc Hosp Pharm, 21(2), 1-12 |
5 | Choi M. H., Park S. H., Choi B. K. Kang Ch. S., Lee S. H., Kim G. S. (2000). Tests for Volume of injectionsn containers. J Korean Pharm Sci, 30(3), 223-228 |
6 | Reduction of injection prescription. (2004, September 10). Chol News, http://news.chol.com/webnews/module |
7 | Waller, D. G., & George, C. F. (1986). Ampules, infusions, and filters. Br Med J, 292, 714-715 DOI |
8 | Pinnock, C. A. (1984). Particulate contamination for intrarthecal use. Ann R Coli Surg Engl, 66, 423 |
9 | Sabon, R. L., Cheng, E. Y., Stommel, K. A., & Hennen, C. R. (1989). Glass particle contamination : Influence of aspiration methods and ampule type. Anesthesiology, 70, 859-862 DOI ScienceOn |
10 | Suk, M. H., Gil, S. Y., & Park, H. J. (2002). The effects of guided imagery on nursing students performing intramuscular injections. J Korean Acad Nurs, 32(6), 784-791 과학기술학회마을 DOI |
11 | Chae, J. H., Kim, W.O., Kil, H. K., & Kim, J. R. (1990). Glass particle contamination in single dose ampules upon opening. Korean J Anestheisol, 23(5), 668-691 |
12 | Park, K. J. (2002). Issues of injection on children' hospital. J Korean Soc Health-Syst. Pharm, 19(2), 153-156 |
13 | Shaw, N. J., & Lyall, E. G. H. (1985). Hazards of glass ampules. Br Med J, 291, 1390 DOI |
14 | Falchuk K. H., Peterson L., & McNeil B. J. (1985). Micro-particulate-induced phlebitis: Its prevention by in line filtration. N Engl J Med, 312, 78-82 DOI ScienceOn |
15 | Katz, H., Borden, H., &Hirscher, D. (1973). Glass-particle contamination of color-break ampules. Anesthesiology, 39(3), 354 DOI ScienceOn |
16 | Sung, G. M. (2003). Differences in perceived and muscle contraction by intramuscular injection methods. Unpublished master's thesis, Konkuk University, Seoul |
17 | Kim, K. S. (1988). Comparison of two intramuscular injection techniques on the severity of discomfort and lesions at the injection site. J Korean Acad Nurs, 18(3), 257-268 과학기술학회마을 |
18 | Purdue, H., & Punchihewa, V. G. (1982). Glass fragments in thiopenlone sodium solution. Anaesthesia, 37, 101-102 |