In this study, the characteristics of the heat transfer coefficient and pressure drop were numerically analyzed according to the axis ratio (AR), pitch, location of vortex generator, and bump phase of the tube surface about an elliptical fin-tube heat exchanger. The boundary condition for CFD analysis was decided as a tube surface temperature of 348 K and inlet air velocity of 1-5 m/s. RSM 7th turbulent model was chosen as the numerical analysis for the sensitivity level. The analysis results indicated that the AR and transverse pitch decreased whereas the heat transfer coefficient increased. On the other hand, there was little difference in the longitudinal pitch. Furthermore, the heat transfer rate was more favorable when the vortex generator was located in front of the tube. Also, the bump phase of the tube surface indicated that the pressure drop and heat transfer were more favorable with the circle type than with the serrated type.
Keywords
AR; CFD; Fin-Tube Heat Exchanger; Vortex Generator; Serrated Tube; RSM;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Myung, H. G., 2002, Data processing of Heat Fluid Engineering, 4th Int. Munundang, pp. 223-225.
2 Park, J. Y. and Baek, J. H., 1996, "A Comparative Study of PISO, SIMPLE, SIMPLE-C Algorithms in 3-Dimensional Generalized Coordinate Systems," Transactions of. KSCFE, Vol. 1, pp. 26-34.   과학기술학회마을
3 Myung, H. G., 2002, CFD introduction, 1th Int. Munundang, pp. 323-328.
4 Jawarneh, A. M. and Vatistas, G. H., 2006, "Reynolds Stress Model in the Prediction Confined Turbulent Swirling Flows," Journal of Fluids Engineering, Vol. 128, pp. 1377-1382.   DOI   ScienceOn
5 Kuznik, F., Brau, J. and Rusaouen, G., 2007, "A RSM Model for the Prediction of Heat and Mass Transfer in a Ventilated Room," Proceedings of Building Simulation, pp. 919-926.
6 Eiamsa-ard, S., Ridluan, A., Somravysin, P. and Promvonge, P., 2008, "Numerical Investigation of Turbulent Flow Through a Circular Orifice," Journal of KMITL Sci., Vol. 8, No. 1, pp. 43-50.
7 Chun, C. H., Jang, G. H., No, H. K. and Lim, K. B., 2008, Heat Transfer introduction, 1th Int. Bosungkak, pp. 223-230.
8 Choi, Y. G., Kim, J. S., Yoon S. H., Kim, M. H. and Oh, C., 2006, "Numerical Study for Fluid and Heat Transfer of Fin-Tube Heat Exchangers with Oval-Tube," Proceedings of KOSME, pp.227-228.
9 Chang, H. S., Chun, Y. W. and Chung I. K., 2005, "Study on Performance of Plate Fin-Oval Tube Heat Exchanger with Vortex Generators," Proceedings of KSME, pp. 345-350.   과학기술학회마을
10 Chiu, Y. W., Lin, Y. X., Jang, J. Y., 2007, "Numerical and Experimental Analysis of Elliptic Finned-Tube Heat Exchangers Under Misted Conditions," Proceedings of Clima 2007 Wellbeing Indoors.
11 Lee, J. H., Lim, M. G. and Kang, H. C., 2010, "Air-side Thermal Performance According to the Fin Shapes of Slit Fin Tube Heat Exchanger," Proceedings of SAREK, pp. 1498-1505.
12 Moh, J. H. and Lee, S. H., 2009, "Analysis for Air-Side Convective Heat Transfer Characteristics in Compact Heat Exchangers," Proceedings of SAREK, pp. 1443-1448.
13 Mcilwain, S. R., 2010, "A Comparison of Heat Transfer Around a Single Serrated Finned Tube and a Plain Finned Tube," Proceedings of IJRRAS 2(2), pp. 88-94.
14 Mcilwain, S. R., 2010, "A CFD Comparison of Heat Transfer and Pressure Drop Across Inline Arrangement Serrated Finned Tube Heat Exchangers with an Increasing Number of Rows," Proceedings of IJRRAS 4(2), pp. 162-169.