Experimental Study of Power Generation Performance of Small-Scale Thermoelectric System  

Chung, Jae-Hoon (School of Mechanical Engineering, Yonsei Univ.)
Kim, Woo-Chul (School of Mechanical Engineering, Yonsei Univ.)
Lee, Jin-Ho (School of Mechanical Engineering, Yonsei Univ.)
Yu, Tae-U (Industrial Facility Team, KITECH)
Publication Information
Transactions of the Korean Society of Mechanical Engineers B / v.34, no.4, 2010 , pp. 383-390 More about this Journal
Abstract
In this study, a thermoelectric power generation system was constructed for a waste-heat recovery. Thermoelectric modules were attached to a stainless steel duct, and a hot air blower was set such that it faced the duct inlet. We found that to achieve the maximum power out of the system, the temperature in the hot side of the thermoelectric module should be uniform. The optimum compressive pressure exerted on the module was observed. Further, the thermoelectric power performance was evaluated using the heat sink attached to the cold side of the thermoelectric module. In particular, when using a natural-convection heat sink, the power output difference is approximately five times.
Keywords
Thermoelectric Generation; Waste Heat Recovery;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 Nuwayhid, R. Y., Shihadeh, A., Ghaddar, N., 2005, "Development and Testing of a Domestic Woodstove Thermoelectric Generator with Natural Convection Cooling," Energy Conversion Management, Vol. 46, pp. 1631-1643.
2 Ikoma, K., Munekiyo, M., Furuya, K., Kobayashi, M., Izumi, T. and Shinohara, K., 1998, "Thermo- electric Module and Generator for Gasoline Engine Vehicles," 17th Int. Conf. on Thermoelectrics, pp. 464-467.
3 Ota, T., Tokunaga, C. and Fujita, K., 2005, "Development of Thermoelectric Power Generation System for Industrial Furnaces," 24th Int. Conf. on Thermoelectrics, pp. 323-326.
4 Rowe, D. M., 2005, Thermoelectrics Handbook: Macro to Nano, CRC Press.
5 Esartea, J., Min, G., and Rowe, D. M., 2001, "Modelling Heat Exchangers for Thermoelectric Generators," J. Power Sources, Vol. 93, pp. 72-76.   DOI   ScienceOn
6 Nagao, K., Nagai, A., Fujii, T., Sakurai, T., Fujimoto, M., and Furue, T., Hayashida, T., Imaizumi, Y., Inoue, T., 1998, "Design of Thermoelectric Generation System Utilizing the Exhaust Gas of Internal-Combustion Power Plant," 17th Int. Conf. on Thermoelectrics, pp. 468-472.
7 Woo B., Lee, H., and Seo, C., 2002, "Characteristic of Electric Generation along Water Flow on Thermoelectric Generator with Hot Water," Trans. of the KSME(B), Vol. 26, pp. 1333-1340.
8 Park, T., 2001, Research on the Economic Waste Heat Recovery Technology using Thermoelectric Generation, Korean Institute of Energy Research.
9 Leavitt, F. A., Elsner N. B., and Bass, J. C. , "Use, application and testing of Hi-Z thermoelectric modules," Hi-Z website brochure, pp. 1-8.
10 Crane, D. T., and Jackson, G. S., 2004, "Optimization of Cross Flow Heat Exchangers for Thermoelectric Waste Heat Recovery," Energy Conversion Management, Vol. 45, pp. 1565-1582.