Study on Correlation of Droplet Flow Rate and Film Boiling Heat Transfer in Spray Cooling  

Yun, Seung-Min (안동대학교 대학원 기계공학부)
Kim, Yeung-Chan (안동대학교 기계공학부)
Publication Information
Transactions of the Korean Society of Mechanical Engineers B / v.31, no.4, 2007 , pp. 335-340 More about this Journal
Abstract
A new correlation between the Nusselt number based on modified heat transfer coefficient and Reynold number based on droplet-flow-rate was developed for the experimental data. The modified heat transfer coefficient was defined as ratio of wall heat flux to droplet subcooling. In the previous reports, the local heat flux of spray cooling in the film boiling region was experimentally investigated for the water spray region of $D_{max} = 0.0007{\sim}0.03m^3/(m^2s)$ . In the region near the stagnation point of spray flow, a new heat transfer correlation is recommended which shows good predictions for the water spray region of $D_x{\le}0.01m^3/(m^2s)$.
Keywords
Spray Cooling; Heat Transfer; Droplet Flow Rate; Film Boiling; Heat Treatment;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Kim, Y. C., Nishio, S. and Ohkubo, H., 1996, 'Spray Cooling with Formation of Liquid Film : Film Boiling Heat Transfer of Liquid Flim Flow,' Trans. of the JSME, Vol. 62-594, pp. 734-739
2 Nishio, S. and Kim, Y. C., 1998, 'Heat Transfer of Dilute Spray Impinging on Hot Surface,' Int. J. of Heat & Mass Transfer, Vol. 41, pp. 4113-4119   DOI   ScienceOn
3 Shoji, S., Wakunaga, T. and Kodama, K., 1984, 'Heat Transfer between Hot Surface and Impinging Subcooled Droplet,' Trans. of the JSME, Vol. 50(B), pp. 716-723
4 Ito, T., Takata, Y. and Mousa, M. M., 1992, 'Study on the Water Cooling of Hot Surface (Analysis of Spray Cooling in the Region Associated with Film Boiling),' JSME Int. J. Series 2, pp. 589-597
5 Kim, Y. C., Nishio, S. and Ohkubo, H., 1996, 'Heat Transfer in High Temperature Region of Spray Cooling Interacting with Liquid Film Flow,' Trans. of the JSME, Vol. 62-597, pp. 1991-1997
6 Kim, Y. C. , 2005, 'Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region,' Trans. of the KSME(B), Vol. 29-2, pp. 279-286   과학기술학회마을   DOI
7 Kim, Y. C. , 2006, 'Study on Film Boiling Heat Transfer of Spray Cooling in Air-Water Full Cone Spray System,' Proceeding of the KSME 2006 Spring Annual Meeting, pp. 2611-2616
8 Wang, B. X. and Shi, D. H., 1985, 'A Semiempirical Theory for Forced-flow Turbulent Film Boiling of Subcooled Liquid along a Horizontal Plate,' Int. J. of Heat & Mass Transfer, Vol. 28-8, pp. 1499-1505   DOI   ScienceOn
9 Muller, H. and Jescher, R., 1973, 'Investigation of the Heat Transfer in a Simulated Secondary Cooling Zone in the Continuous Casting Process,' Arch Eisenhuttenwes, Vol.44-8, pp. 589-594
10 Ohkubo, H. and Nishio, S., 1990, 'Study on Accurate Prediction of Heat Transfer Characters of Mist Cooling,' JSME International Journal, Vol. 33-2, pp. 326-33
11 Kim, Y. C., Nishio, S. and Ohkubo, H., 1994, 'Spray Cooling with Formation of Liquid Film Flow : Distribution of Heat Transfer Coefficient in High Temperature Region,' Trans. of the JSME, Vol.60-574, pp. 2158-2164
12 Bolle, L. and Moureau, J. C., 1978, 'Spray Cooling of Hot Surface,' Multiple Science and Technology, pp. 76-90