Browse > Article
http://dx.doi.org/10.3795/KSME-A.2012.36.8.865

Research on Pre- and Post-Processor for Analysis of Proportional Solenoid Valve  

Yun, Dong-Won (Robotics and Mechatronics Research Center, Korea Institute of Machinery and Materials)
Ham, Sang-Yong (Robotics and Mechatronics Research Center, Korea Institute of Machinery and Materials)
Park, Jung-Ho (Department of Energy Systems, Korea Institute of Machinery and Materials)
Yun, So-Nam (Department of Energy Systems, Korea Institute of Machinery and Materials)
Kim, Chil-Sung (SVC Inc.)
Publication Information
Transactions of the Korean Society of Mechanical Engineers A / v.36, no.8, 2012 , pp. 865-871 More about this Journal
Abstract
In this study, a wrapping program was developed to analyze a proportional solenoid valve more easily using a conventional finite element method (FEM) tool. To achieve an accurate solution when analyzing a solenoid valve, finite element analysis (FEA) is more suitable than a lumped method. To develop a program for modeling and analyzing the valve performance using FEA code for the user's convenience, it is assumed that the solenoid valve is composed of some simple geometries, namely, a triangle and a rectangle. This assumption helps users to model a solenoid valve simply. To check the feasibility of the developed code, an actual solenoid valve is analyzed, and it is found that the code can suitably analyze this valve. The characteristics of the proportional valve are well identified as indicated through the graphs.
Keywords
Solenoid; Valve; FEM; Proportional Valve;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Kim, D. S., Park, S. W. and Koh, C. S., 2005, "The Optimal Design by Micro On-Off Valve Analysis," Proceedings of KSPE.   과학기술학회마을
2 Wang, S.-M., Miyano, T. and Hubbard, M., 1993, "Electromagnetic Field Analysis and Dynamic Simulation of a Two-Valve Solenoid Actuator," IEEE Transactions on Magnetics, Vol. 29, No. 2, pp.1741-1746.   DOI   ScienceOn
3 Mitsutake, Y. and Hirata, K., 1997, "Dynamic Response Analysis of a Linear Solenoid Actuator," IEEE Transaction on Magnetics, Vol. 33, pp. 1634-1637.   DOI   ScienceOn
4 Kim, D. G., Jeong, H. H., Jung, E. A. and Yun, S. N., 2010, "A Study on Attraction Force Improvement by Control Cone Angle Variation of Proportional Solenoid Actuator," Proceeding of KSPE, pp. 1055-1056.   과학기술학회마을
5 Yun, S.-N., Youn, D.-W., Jung, Y.-H., Ryu, J.-S. and Jo, J.-H., 2005, "High Pressure Control Valve for Common Rail System," KSAE 2005 Autumn Conference, pp.499-503.
6 Yun, S. N., Ham, Y. B. and Jo, J. D., 2003, "Pressure Control Characteristics of Proportional Pressure Reducing Valve," Transactions of The Korean Society for Power System Engineering, Vol.7, No.1, pp.68-73.   과학기술학회마을
7 Ryu, J. S., Koh, C. S., Yun, S. and Ham, Y., 2003, "Characteristics Analysis of the Solenoid for High-Voltage Circuit Breaker," Proceedings of KIEE, pp.912-914.   과학기술학회마을
8 Yun, S., Kang, B., Sung, B. and Kim, H., 2000, "A Study on Characteristics of Nozzle/ Flapper Type Flow Control Servo Valve," Transactions of KSAE, Vol.18, No.1, pp.54-62.   과학기술학회마을