Abstract
This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and counting experiment with Sephadex G-25 beads ($70{\sim}100\;{\mu}m$). The pumping part consisted of a microheater, catalyst (manganese dioxide) enveloped with paraffin, hydrogen peroxide, and microchannel, and the counting part consisted of collimated light, a microwindow, and a phototransistor including an external circuit. The micropump generated oxygen gas by decomposing hydrogen peroxide with manganese dioxide, which was initiated by melting the paraffin with the microheater, and pumped beads in the microchannel. When the beads passed the microwindow, they shaded the collimated light and changed the illumination on the phototransistor, which caused the current variation in the circuit. The signals, according to the bead size, reached up to 22 mV with noise level of 2 mV during 50 seconds and the numbers of peaks were analyzed by magnitude.
Keywords
Micro Cell Counter; Oxygen Micropump; Microchannel; Sizing;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Atanasov, P. A. and Imamova, S. E., 2000, 'Optical Parameters of Silicon Carbide and Silicon Nitride Ceramics in 0.2-1.3 ${\mu}m$ Spectral Range,' J. Applied physics, Vol. 88, No.8, pp. 4671-4675   DOI   ScienceOn
2 Son, S. U. and Lee, S. S., 2003, 'Narrowing Microfluid Width in Microchannel Using Air Boundaries,' Proc. Int. Conf. On Micro Total Analysis Systems $({\mu}TAS pp. 147-150
3 Jang, J. and Lee, S.S., 2000, 'Theoretical and Experimental Study of MHD (Magnetodydro Dynamic) Micropump,' Sen. and Act. A, Vol. 80, pp. 84-89   DOI   ScienceOn
4 Xie, J., He, Q., Tai, Y.-C., Liu, J. and Lee, T., 2002, 'Integrated Electrospray Chip for Mass Spectrometry,' Proc. Int. Conf. On Micro Total Analysis Systems $({\mu}JTAS pp. 709-711
5 Yo Han Choi, Sanguk Son and Seung S. Lee, 2003, 'Novel Micropump Using Oxygen as Pumping Source,' Proceedings of the 16th IEEE MEMS conference, pp. 116-119   DOI
6 Chien-Chong Hong, Suresh Murugesan, Sanghyo Kim, Gregory Beaucage, Jin-Woo Choi and Chong H. Ahn, 2003, 'A Functional On-chip Pressure Generator Using Solid Chemical Propellant for Disposable Lab-on-a-chip,' Proceedings of the 16th IEEE MEMS conference, pp. 16-19   DOI
7 Son, S. U., Choi, Y. H. and Lee, S. S., 2003, 'Fabrication of Micro Cell Counter Integrated with Oxygen Pump,' Proc. Korean MEMS Conf., pp. 436-440
8 Chang, R., 1981, 'Chemistry,' 2nd ed., Random House, New York, p. 63, p. 591
9 Hatch, A., Kamholz, A. E., Holman, G., Yager, P., and Bohringer, K. F., 2001, 'A Ferrofluidic Magnetic Micropump,' J. Microelectromech. Sys., Vol. 10, No. 2, pp. 215-221   DOI   ScienceOn
10 Chujo, H., Matsumoto, K. and Shimoyama, I., 2003, 'A High Flow Rate Electroosmotic Pump with Small Channels in Parallel,' Proc. IEEE Int. Conf. On Micro Electro Mechanical Systems (MEMS'03), pp. 351-354   DOI
11 Morgan, H., Green, N. G., Hughes, M. P., Monaghan, W. and Tan, T. C., 1997, 'Large-Area Travelling-Wave Dielectrophoresis Particle Separator,' J. Micromech. Microeng., Vol. 7, pp. 65-70   DOI   ScienceOn
12 Wolff, A., Perch-Nielsen, I. R., Larsen, U. D., Friis, P., Goranovic, G., Poulsen, C. R., Kutter, J. P. and Telleman, P., 2003, 'Integrating Advanced Functionality in a Microfabricated High-Throughput Fluorescent-Activated Cell Sorter,' Lab on a Chip, Vol 3, pp. 22-27   DOI   ScienceOn
13 Roberts, K., Parameswaran, M., Moore, M. and Muller, R.S., 1999, 'A Silicon Microfabricated Aperture for Counting Cells Using the Aperture Impedance Technique,' Proc. IEEE Canadian Conf. On Electrical and Computer Engineering, pp. 1668-1673   DOI
14 Altendorf, E., Zebert, D., Holl, M. and Yager, P., 1997, 'Differential Blood Cell Counts Obtained Using a Microchannel Based Flow Cytometer,' Proc. Int. Conf. On Solid-State Sensors and Actuators (Transducers '97), pp. 531-534   DOI
15 Carlen, E. T. and Mastrangelo, C. H., 2000, 'Paraffin Actuated Surface Micromachined Valves,' Proc. IEEE Int. Conf. On Micro Electro Mechanical Systems (MEMS'00), pp. 381-385   DOI
16 Wang, X., Zhou, Z., Ye, X., Li, Y. and Zhang, W., 1998, 'A PZT-Driven Micropump,' Proc. Int. Sym. On Micromechatronics and Human Science, pp. 269-272   DOI
17 Gawad, S., Schild, L. and Renaud, Ph., 2001, 'Micromachined Impedance Spectroscopy Flow Cytometer for Cell Analysis and Particle Sizing,' Lab on a Chip, Vol. 1, pp. 76-82   DOI   ScienceOn
18 FACSVantage SE User's Guide, Becton, Dickinson and Company, USA, p. 176
19 Onoda, H., Takamura, Y. and Horiike, Y. 2002, 'Electric Damage Free Separation Chip of Lymphocytes Sub-Unit Employing High Pressure Electroosmosis Pump,' Proc. Int. Conf. On Micro Total Analysis Systems $({\mu}JTAS pp. 955-957
20 Larsen, U.D., Blankenstein, G. and Branebjerg, J., 1997, 'Microchip Coulter Particle Counter,' Proc. Int. Conf. On Solid-State Sensors and Actuators (Transducers '97), pp. 1319-1322   DOI