Browse > Article
http://dx.doi.org/10.5659/JAIK.2022.38.3.241

AnalysisFeasibility Study on the Assessing Surface Finishing TimeManagement of Concrete by Settimeter(Setting time meter)  

Han, Soo-Hwan (Dept. of Architectural Engineering, Cheongju University)
Kim, Jong (Dept. of Architectural Engineering, Cheongju University)
Han, Min-Cheol (Dept. of Architectural Engineering, Cheongju University)
Han, Cheon-Goo (Dept. of Architectural Engineering, Cheongju University)
Publication Information
Journal of the Architectural Institute of Korea / v.38, no.3, 2022 , pp. 241-247 More about this Journal
Abstract
This study attempts to find a correlation between the hardness of the set meter and from analyzing the field applicability, to propose a scientific setting time determination method when working on concrete surface finishing. The results indicated that surface finish time management is possible if the concrete surface finish work at the site manages to start at the initial time before and after 45HD of the set meter hardness. Further analysis is needed to collect enough data to statistically process at more work sites to prove its effectiveness. Overall, if the concrete surface finishing work hours reach a consensus in practical application, it could contribute to the transformation of quality scientific management.
Keywords
Finisher; Durometer; Settimeter (Setting time meter); Surface Finishing Time of Concrete; Setting Time;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lee H.J., Choi Y.H., Lee J.S., Han D.Y., Han I.D., & Han, M.C. (2019). Estimation of Setting Time Using Improved Type Durometer of Powdered High Fluidity Concrete. Proceedings of Korean Society for Atmospheric Environment, (19)1. 17-18.
2 KS F 2436 (2017) Standard test method for setting times of concrete mixture by penetration resistance
3 Kato, J., Makishima, & O. (2017). Proposal for effective construction management technique by setting management at concrete placement. Proceedings of Architecture Institute of Japan, 423-424. [in Japan]
4 Han, M., Han, I., & Shin, Y. (2019). Estimation of Setting Time of Concrete Using Rubber Hardness Meter. Journal of the Korean Recycled Construction Resources Institute, 7(4), 358-366.   DOI
5 Han C., Han M., & Shin Y. (2020). Feasibility Study of Modified Durometer to Evaluate Setting Time of the Concrete. Journal of the Korea Institute of Building Construction. 20(5), 433-440.
6 Lee, H.J., Chol, Y.H., Lee, Y.J., Shin Y.S., Han M.C., & Han, C.G. (2019). An Analysis on the Possibility of Using the Improved Durometer in Estimating the Setting Time according to the Temperature Variation of High Strength Concrete. Proceedings of the Architectural Institute of Korea, 39(1), 620-621.
7 Korea Concrete Institue (2010). Concrete working manual, Concrete curing. Kimoondang, 17-18.
8 Han, Mi., Shin, Y., & Han, I. (2019). Estimation of the Setting Time of the High Flowing Concrete Using Durometer. Journal of the Architectural Institute of Korea Structure & Construction, 35(9), 143-150.   DOI