3-Dimensional Numerical Modeling of a Single Ground Heat Exchanger for Low-Energy Houses  

Kim, Eui-Jong (프랑스 국립 과학 연구소(CNRS))
Publication Information
Journal of the Architectural Institute of Korea Planning & Design / v.30, no.5, 2014 , pp. 237-244 More about this Journal
Abstract
This paper aims at developing a three-dimensional numerical model of a single ground heat exchanger that would be enough to handle the heating and cooling loads of low-energy houses. As a reduced model (Linear Aggregation Method) previously developed is not yet sufficiently efficient in computation, some simplification schemes are newly proposed for the coupling of sub-zone models that are obtained from domain sub-structuring, which was mandatory to use the reduction method. The proposed model is compared to a reference model and the well-known existing model DST. Results from the 3-D numerical model implemented in Dymola are in a good agreement with the reference models, within a range of $0.2^{\circ}C$ in difference, and the computation efficiency is much enhanced with the proposed simplifications.
Keywords
Ground Heat Exchanger; 3-Dimensional Numerical Model; Model Reduction;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chiasson A. and Yavuzturk C. Assessment of the viability of hybrid geothermal heat pump systems with solar therma l collectors. ASHRAE Transactions, vol. 109, no. 2, pages 487-500, 2003.
2 Eslami-nejad P. and Bernier M. A Preliminary Assessment on the Use of Phase Change Materials around Geothermal Boreholes. ASHRAE Transactions, vol. 119, no. 2, pages 31 2-321
3 He M., Rees S. and Shao L. Simulation of a domestic ground source heat pump system using a transient numerical borehole heat exchanger model. In Building Simulation 2009, pages 607--614, Glasgow, Scotland, July 2009.
4 Ingersoll L.R. and Plass. H.J. Theory of the ground pipe heat sourcefor the heat pump. Heating, Piping and Air conditioning, vol. 20, pages 119-122, 1948.
5 Kim E.J., Roux J.J., Bernier M.A., and Cauret O., Three -dimensional numerical modeling of vertical ground heat exchangers: Domain decomposition and state model reduction, HVAC&R Research, 17(6) (2011a) 912-927.
6 Kim, E.J., J.J. Roux, G. Rusaouen, and F. Kuznik. 2010. Numerical modelling of geothermal vertical heat exchangers for the short time analysis using the state model size reduction technique. Applied Thermal Engineering 30(6-7):706-14.   DOI   ScienceOn
7 Marshall S.A. An approximate method for reducing the order of a linear system, Control 10 (1966) 642-643.
8 Micha G.P. Approximation des systemes complexes par des modeles de dimension reduite, These d'Etat, Centre d'Orsay, Universite de Paris-sud, 1979.
9 Trillat-Berdal V, Souyri B. and Fraisse G. Experimental st udy of a ground-coupled heat pump combined with thermal solar collectors. Energy and Buildings, vol. 38, no. 12, pages 1477-1484, 2006.   DOI   ScienceOn
10 Kim EJ., Development of numerical models of vertical ground heat exchangers and experimental verification: Domain Decomposition and State Model Reduction Approach, These de doctorat, INSA de Lyon, 2011b