Browse > Article
http://dx.doi.org/10.5659/JAIK_PD.2014.30.11.177

An Experimental Study on Thermal Performance of Double Skin Facade in Residential Buildings  

Joe, Goo-Sang (서울대 대학원 건축학과)
Kim, Ji-Hye (서울대 대학원 건축학과)
Yeo, Myoung-Souk (서울대 건축학과)
Kim, Kwang-Woo (서울대 건축학과)
Publication Information
Journal of the Architectural Institute of Korea Planning & Design / v.30, no.11, 2014 , pp. 177-184 More about this Journal
Abstract
The objective of this study is to evaluate thermal performance of suggested double skin façade by comparing with conventional façade. The evaluation was performed by experiments of conventional façade and double skin façade through the extreme conditions. For evaluation of thermal performance, peak cooling load and peak heating load is measured. For this measurement, ceiling, floor, all the walls are adiabatic condition except for the location of building façade. And to keep the constant indoor temperature, air is supplied through AHU. In the process of evaluation on thermal performance, outdoor temperatures is applied maximum temperature of daytime in summer condition and minimum temperature of nighttime in winter condition using Seoul weather data. Indoor temperature is used Recommended temperature of energy conservation code in Korea. And according to the survey, Maximum vertical solar radiation during the daytime is applied. As a results, Double skin façade could reduce peak cooling load by 60% or more than conventional façade during summer peak condition. And the operation of double skin façade during winter peak condition also could reduce peak heating load by 30% or more than operating conventional façade.
Keywords
Double Skin Facade; Thermal Performance; High-rise Residential Buildings; Experiment;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Cho, Gayoung et al, Design Parameters of Double-Skin Facade for Improving the Perfromance of Natural Ventilation in High-Rise Residential Builidngs, Journal of Asian Architecture and Building Engineering, 2013
2 Joe, Goosang et al, An Experimental Study on Thermal Performance of Double Skin Facade, 8th ISAIA, 2010
3 Jin Woo Moon et al.,Determining optimum control of double skin envelpoe for indoor thermal environment based on artificial neural network, Energy and Buildings, 2014
4 J. Darkwa et al., Heat transfer and air movement behaviour in a double-skin facade, Sustainable Cities and Society, 2014
5 이소연, 강재식, 김강수, 주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구, 한국태양에너지학회 논문집 제30권 제6호, p.p.1-9, 2010   과학기술학회마을
6 김광우, 이중외피 시스템의 개요와 국내외 현황, 대한건축학회지 47(9), p.p.28-33, 2003
7 김동균, 윤갑천, 강재식, 김강수, 이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구, 한국태양에너지학회 논문집 제31권 제1호, p.p.59-67, 2011   과학기술학회마을   DOI   ScienceOn
8 김지혜, 이현정, 이미진, 윤병희, 여명석, 김광우, 인공기후 Mock-up 실험에 의한 이중외피 시스템의 열성능 평가, 한국건축친환경설비학회 춘계학술발표대회 논문집, p.p.105-108, 2009
9 원현성, 오세규, 공동주택 거실 공간 발코니 확장 시 이중외피 적용을 위한 설계 가이드라인 연구, 대한건축학회 논문집, p.p.11-19, 2012   과학기술학회마을
10 조구상, 주거건물용 이중외피의 중공층 열적특성에 관한 연구, 서울대학교 석사학위 논문, 2009