Abstract
The bracket-type connection is often used for the weak axis steel connection of H-shape beam-to-column. However it leads to weakness of competitiveness in steel structure due to difficulty in production and installation of connection. Consequently, new shape weak-axis was developed. It has a simple shape with the less spot of welding points, and has advantage about showing the obvious power flow in connection points. In this study, monotonic and cyclic loading test in full-scale was performed to evaluate structural behavior and examine on-site application. Therefore, 12 specimens(9 specimens for monotonic loading test and 3 specimens for cyclic loading test) were built for the variables which are overlap length of beam-end and column flange. As the result, new shape of weak-axis connection appeared special Moment Frame(SMF) and had excellent structural performance and constructablility when the parameter is over 50mm.
Keywords
Full-scale; New Shape; Weak Axis Connection; Welding Plate; Consturctability; Performance Evaluation;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 최성모, 박수희, 박영욱, 김진호, CFT 각형 기둥-보 합성 반강접 접합부의 이력거동, 대한건축학회 논문집, 21권, 6호, 21(6), p.p.25-32, 2005   과학기술학회마을
2 오상훈, 지진을 고려하지 않은 강구조 보-기둥접합부, 한국강구조학회지, 14권, 4호, 14(4), p.p.1-8, 2002
3 서정환, 양영성, 서성연, 김규석, 축력과 휨모멘트를 받는 원형강관 기둥의 이력거동에 관한 연구, 대한건축학회 논문집, 12권, 3호, 12(3), p.p.173-183, 1996   과학기술학회마을
4 American Institute of Steel Construction, LRFD, 1989, 2005, 2010
5 Gilton, C.S., Uang C.M., Cyclic Response and Design Recommendations of Weak-Axis Reduced Beam Section Moment Connections, Journal of structural engineering, ASCE, vol. 128, no. 4, p.p.452-463, 2002   DOI   ScienceOn
6 Iwankiw, N.R., Engineering journal, Ultimate strength considerations for seismic design of the reduced beam section(Internal plastic hinge), vol.34 no.1, p.p.3-10, 1997
7 Huang, D., Wang, L. and Zhang, J., Building structure, Evaluation on Aseismic Performance of Beam-column Joints with Welded Haunch Beam, vol.34 no.6, p.p.49-50, 2004
8 Pachoumis, D.T., Galoussis, E.G and Kalfas, C.N., Engineering structures, Reduced beam section moment connections subjected to cyclic loading: Experimental analysis and FEM simulation, vol.31 no.1, p.p.216-223, 2009   DOI   ScienceOn
9 이강민, 정희택, 윤석용, 이은모, 오경환, 브라켓 및 WUF-B 형상 철골모멘트골조 약축접합부 내진성능평가, 한국강구조학회 논문집, 20권, 4호, 20(4), p.p.483-491, 2008   과학기술학회마을
10 김상섭, 이도형, 함정태, 김규석, H형강 기둥의 약축에 대한 기둥-보 접합상세 개발 및 내력평가, 한국강구조학회 논문집, 16권, 1호, 16(1), p.p.1169-180, 2004   과학기술학회마을
11 한국강구조학회, 건축강구조 표준접합상세지침, 구미서관, 2010
12 이도형, 함정태, 김성배, 김영호, 김상섭, 수평스티프너를 이용한 철골 기둥-보 약축접합부 상세 개발에 관한 연구, 한국강구조학회 논문집, 16권, 5호, 16(5), p.p.641-652, 2004   과학기술학회마을
13 Kim, S.D., Kim, S.S. and Ju, Y.K., Strength evaluation of beam-column connection in the weak axis of H-shaped column, Engineering structures, ELSEVIER, vol.30 no.6, p.p.1699-1710, 2008   DOI   ScienceOn
14 김상섭, 부윤섭, 초간편 H형강 기둥-보 약축접합부의 구조성능 및 $CO_2$ 저감량 평가, 한국강구조학회 논문집, 23권, 5호, 23(5), p.p.615-627, 2011   과학기술학회마을
15 American Institute of Steel Construction, AISC 2006 Seismic Design Manual, 2006
16 CEN, Eruocode 3, Part 1.1, 1993
17 김필중, 부윤섭, 양재근, 이은택, 김상섭, 시공성 향상을 위한 제4세대 H형강 기둥-보 약축접합부의 개발 및 성능평가, 한국강구조학회 논문집, 23권, 3호, 23(3), p.p.295-301, 2011   과학기술학회마을