Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine  

Park, Jeong-Kyu (대구보건대학 방사선과)
Cho, Euy-Hyun (영남대학교 의공학과)
Publication Information
Journal of Digital Contents Society / v.13, no.2, 2012 , pp. 151-157 More about this Journal
Abstract
Even though the protective facility is well made with the development of medicine, the spatial dose within the radiation section could increase the exposure of the workers. The spatial dose is always present in distribution room within the Department of Nuclear Medicine, so the spatial dose of the interior distribution room is measured and analyzed for the prediction of the exposure dose. The spatial dose rate was $6.78{\pm}0.083{\mu}Sv/h$ in the $^{18}F$ distribution room of department of Nuclear Medicine, $9.248{\pm}0.013{\mu}Sv/h$ in $^{99m}Tc$, and $^{131}I$ distribution room. In addition, in case of $^{18}F$ distribution room, the yearly external exposure dose was $42.5{\mu}Sv$ when the nurse does IV in 1m in distance. It also showed that the spatial dose rate on the direction of right oblique showed higher than others by the standard of distribution window of distribution room. Therefore, the staying time of the workers should be short during distributing radiopharmaceuticals in the distribution room and the design of the distribution protection is necessary to reduce the exposure in the direction of right oblique of the protection. The utmost endeavors are required to reduce the worker's individual exposure dose while doing IV.
Keywords
Radiation Protection; Distribution Room; Spatial Dose Rate;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 오현주 외 "X선 촬영실내에서의 공간산란선량 변동에 관한 연구", 대한 방사선기술학회지, 17(2), pp21-27,1994
2 Jung - Min Kim, Sung Chul Kim X-ray dose at the time of diagnosis Thickness Cu filter to reduce by half, Radiology Technology, No. 24, pp17-22, 2001
3 강호윤 외 "휴대용 핵종분석기의 방향의존성 측정", 대구보건대학 학술대회 논문집, 2010
4 박명환, "전신 PET/CT 검사에서 공간선량률 측정", 대한방사선기술과학회지 29(4), pp257-260, 2006   과학기술학회마을
5 Nuclear Safety Commission Notice "on radiation pr otection standards, such as" No. 2011-29
6 Gwang-yeol Yu "Sunshine electron emission due to the use of radionuclides in nuclear medicine labor atory safety management," Nuclear Technology 5 (2), pp280-287, 2000
7 Byung - Joon Kwak, "PET-CT scan study on the spatial dose rate measurements," Pusan Catholic Un iversity School of Health Sciences, Master Thesis, 2009
8 佐藤孝司, 小野光ー:X線撮影空間の散亂線の擧動, 日本放射線技術学会論文誌, 第49巻, 第8号, p1383, 1993
9 ICRP : "Recommendation of the International Commi ssion on Radiological Protection", ICRP Publication 26, Pergamon Press, Oxford, New York, 1977
10 한성규,전수경,정재성, 송서연 "핵의학과내의 공간별 선량률과 개인피폭선량과의 비교", 제 43차 방사선사 학술대회, pp446, 2008
11 R. S. Sloboda, M. G. Schmid, and C.P. Willis : Technologist radiation exposures from nuclear medicine imaging procedures, J. Nucl. Med. Tech., 15, 16-24,1987
12 M. Velchik : Radiation exposure associated with the performance of radiologic studies in radioactive patients, J. Nucl. Med. Tech, 18, pp211-213, 1990
13 L.K. Harding, A. B. Mostafa, L. Roden, N. Williams : Dose rates from patients having nuclear medicine investigations, Nucl. Med. Common., 6, pp191-194,1985   DOI
14 박명환.이준일,"핵의학 검사에서 환자로부터의 공간 선량률 측정", 대한방사선기술학회지 25(1), pp73-76, 2002