Browse > Article
http://dx.doi.org/10.5572/KOSAE.2018.34.4.610

Corrections and Artifacts Regarding Filter-based Measurements of Black Carbon  

Lee, Jeonghoon (School of Mechanical Engineering, Korea University of Technology and Education)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.34, no.4, 2018 , pp. 610-615 More about this Journal
Abstract
A filter-based optical technique is one of the representative ways for the measurement and quantification of black carbon (BC). Since the filter-based technique adopts a simple principle, it is easy to put into practical use and instrumental products have already been commercialized. In this study, however, the absorption coefficients of BC after the correction process was estimated to be approximately 3 times lower than those before the correction process. In addition, the difference between before and after corrections was also evident for the trend of increasing and decreasing absorption coefficient. When BC concentration is low, uncertainty may increase regardless of corrections due to the artifacts of filter. In this sense, techniques without using a filter are required, and uncertainties will be minimized if these techniques are used to further complement the filter-based black carbon measurements. Finally, this study is believed to help understand the uncertainty and correction of filter-based black carbon measurements.
Keywords
Black carbon; Uncertainty; Artifact; Filter-based technique;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Arnott, W., Hamasha, K., Moosmuller, H., Sheridan, P.J., Ogren, J.A. (2005) Towards aerosol light-absorption measurements with a 7-wavelength aethalometer: Evaluation with a photoacoustic instrument and 3-wavelength nephelometer, Aerosol Science and Technology, 39(1), 17-29.   DOI
2 Bond, T.C., Anderson, T.L., Campbell, D. (1999) Calibration and intercomparison of filter-based measurements of visible light absorption by aerosols, Aerosol Science & Technology, 30(6), 582-600.   DOI
3 Collaud Coen, M., Weingartner, E., Apituley, A., Ceburnis, D., Fierz-Schmidhauser, R., Flentje, H., Henzing, J.S., Jennings, S.G., Moerman, M., Petzold, A., Schmid, O., Baltensperger, U. (2010) Minimizing light absorption measurement artifacts of the Aethalometer: evaluation of five correction algorithms, Atmospheric Measurement Techniques, 3, 457-474.   DOI
4 Jung, J.H., Park, S.S. (2010) Characteristics of black carbon in $PM_{2.5}$ observed in Gwangju for Year 2008 and examination of filter loading effect, Jounral of Korean Society for Atmospheric Environment, 26(4), 392-402. (in Korean with English abstract)   DOI
5 Ogren, J.A. (2010) Comment on "Calibration and intercomparison of filter-based measurements of visible light absorption by aerosols", Aerosol Science and Technology, 44(8), 589-591.   DOI
6 Park, S.S., Jung, J.H., Cho, S.Y., Kim, S.J. (2009) Comparison of aethalometer black carbon data observed at a Gwangju site, Jounral of Korean Society for Atmospheric Environment, 25(6), 571-578. (in Korean with English abstract)   DOI
7 Schmid, O., Artaxo, P., Arnott, W.P., Chand, D., Gatti, L.V., Frank, G.P., Hoffer, A., Schnaiter, M., Andreae, M.O. (2006) Spectral light absorption by ambient aerosols influenced by biomass burning in the Amazon Basin. I: Comparison and field calibration of absorption measurement techniques, Atmospheric Chemistry and Physics, 6, 3443-3462.   DOI
8 Weingartner, E., Saathof, H., Schnaiter, M., Streit, N., Bitnar, B., Baltensperger, U. (2003) Absorption of light by soot particles: Determination of the absorption coefficient by means of aethalometers. Journal of Aerosol Science, 34, 1445-1463.   DOI
9 Virkkula, A., Makela, T., Hillamo, R., Yli-Tuomi, T., Hirsikko, A., Hameri, K., Koponen, I.K. (2007) A simple procedure for correcting loading effects of aethalometer data. Journal of Air & Waste Management, 57(10), 1214-1222.   DOI