Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs |
Kwon, Yee-Seo
(Seoul National University School of Dentistry)
Namgoong, Hee (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry) Kim, Jung-Hoon (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry) Cho, In Hee (Implant R&D Center, Osstem Implant Co.) Kim, Myung Duk (Implant R&D Center, Osstem Implant Co.) Eom, Tae Gwan (Implant R&D Center, Osstem Implant Co.) Koo, Ki-Tae (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry) |
1 | Chun HJ, Cheong SY, Han JH, Heo SJ, Chung JP, Rhyu IC, et al. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 2002;29:565-74. DOI ScienceOn |
2 | Kong L, Liu BL, Hu KJ, Li DH, Song YL, Ma P, et al. Optimized thread pitch design and stress analysis of the cylinder screwed dental implant. Hua Xi Kou Qiang Yi Xue Za Zhi 2006;24:509-12, 515. |
3 | Klokkevold PR, Nishimura RD, Adachi M, Caputo A. Osseointegration enhanced by chemical etching of the titanium surface: a torque removal study in the rabbit. Clin Oral Implants Res 1997;8:442-7. DOI ScienceOn |
4 | Carlsson L, Rostlund T, Albrektsson B, Albrektsson T. Removal torques for polished and rough titanium implants. Int J Oral Maxillofac Implants 1988;3:21-4. |
5 | Steigenga JT, al-Shammari KF, Nociti FH, Misch CE, Wang HL. Dental implant design and its relationship to long-term implant success. Implant Dent 2003;12:306-17. DOI ScienceOn |
6 | Shalabi MM, Wolke JG, Jansen JA. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model. Clin Oral Implants Res 2006;17: 172-8. DOI ScienceOn |
7 | Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res 2007;18: 465-70. DOI ScienceOn |
8 | Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs. Clin Implant Dent Relat Res 2006;8:107-13. DOI ScienceOn |
9 | Hudieb MI, Wakabayashi N, Kasugai S. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant. J Periodontol 2011; 82:1061-70. DOI ScienceOn |
10 | Rasmusson L, Kahnberg KE, Tan A. Effects of implant design and surface on bone regeneration and implant stability: an experimental study in the dog mandible. Clin Implant Dent Relat Res 2001;3:2-8. DOI ScienceOn |
11 | Misch CE. Contemporary implant dentistry. 3rd ed. St. Louis: Mosby Elsevier; 2008. |
12 | Chung SH, Heo SJ, Koak JY, Kim SK, Lee JB, Han JS, et al. Effects of implant geometry and surface treatment on osseointegration after functional loading: a dog study. J Oral Rehabil 2008;35:229-36. DOI ScienceOn |
13 | Ma P, Liu HC, Li DH, Lin S, Shi Z, Peng QJ. Influence of helix angle and density on primary stability of immediately loaded dental implants: three-dimensional finite element analysis. Zhonghua Kou Qiang Yi Xue Za Zhi 2007; 42:618-21. |