Browse > Article
http://dx.doi.org/10.5051/jpis.2013.43.1.30

Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test  

Bayarchimeg, Dorjpalam (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Namgoong, Hee (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Kim, Byung Kook (Implant R&D Center, Osstem Implant Co.)
Kim, Myung Duk (Implant R&D Center, Osstem Implant Co.)
Kim, Sungtae (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Kim, Tae-Il (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Seol, Yang Jo (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Lee, Yong Moo (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Ku, Young (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Rhyu, In-Chul (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Lee, Eun Hee (Dental Clinic, Healthcare System Gangnam Center, Seoul National University Hospital)
Koo, Ki-Tae (Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry)
Publication Information
Journal of Periodontal and Implant Science / v.43, no.1, 2013 , pp. 30-36 More about this Journal
Abstract
Purpose: Implant stability at the time of surgery is crucial for the long-term success of dental implants. Primary stability is considered of paramount importance to achieve osseointegration. The purpose of the present study was to investigate the correlation between the insertion torque and primary stability of dental implants using artificial bone blocks with different bone densities and compositions to mimic different circumstances that are encountered in routine daily clinical settings. Methods: In order to validate the objectives, various sized holes were made in bone blocks with different bone densities (#10, #20, #30, #40, and #50) using a surgical drill and insertion torque together with implant stability quotient (ISQ) values that were measured using the Osstell Mentor. The experimental groups under evaluation were subdivided into 5 subgroups according to the circumstances. Results: In group 1, the mean insertion torque and ISQ values increased as the density of the bone blocks increased. For group 2, the mean insertion torque values decreased as the final drill size expanded, but this was not the case for the ISQ values. The mean insertion torque values in group 3 increased with the thickness of the cortical bone, and the same was true for the ISQ values. For group 4, the mean insertion torque values increased as the cancellous bone density increased, but the correlation with the ISQ values was weak. Finally, in group 5, the mean insertion torque decreased as the final drill size increased, but the correlation with the ISQ value was weak. Conclusions: Within the limitations of the study, it was concluded that primary stability does not simply depend on the insertion torque, but also on the bone quality.
Keywords
Bone density; Dental implants; Torque;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Degidi M, Daprile G, Piattelli A, Iezzi G. Development of a new implant primary stability parameter: insertion torque revisited. Clin Implant Dent Relat Res 2011 Oct 18 [Epub]. http://dx.doi.org/10.1111/j.1708-8208.2011.00392.x.
2 Dilek O, Tezulas E, Dincel M. Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:e20-7.   DOI   ScienceOn
3 Stacchi C, Vercellotti T, Torelli L, Furlan F, Di Lenarda R. Changes in implant stability using different site preparation techniques: twist drills versus piezosurgery: a single-blinded, randomized, controlled clinical trial. Clin Implant Dent Relat Res 2011 Apr 19 [Epub]. http://dx.doi.org/10.1111/j.1708-8208.2011.00341.x.
4 Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 2004;15: 520-8.   DOI   ScienceOn
5 Isoda K, Ayukawa Y, Tsukiyama Y, Sogo M, Matsushita Y, Koyano K. Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants. Clin Oral Implants Res 2012;23:832-6.   DOI   ScienceOn
6 Bilhan H, Geckili O, Mumcu E, Bozdag E, Sunbuloglu E, Kutay O. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone. J Oral Rehabil 2010;37:900-7.   DOI   ScienceOn
7 Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci 1998;106: 721-64.   DOI   ScienceOn
8 Degidi M, Daprile G, Piattelli A. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implants. Clin Implant Dent Relat Res 2010 Sep 17 [Epub]. http://dx.doi.org/10.1111/j.1708-8208.2010.00302.x.
9 Degidi M, Perrotti V, Strocchi R, Piattelli A, Iezzi G. Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants. Clin Oral Implants Res 2009;20:778-81.   DOI   ScienceOn
10 Tabassum A, Meijer GJ, Wolke JG, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Implants Res 2010;21:213-20.   DOI   ScienceOn
11 Turkyilmaz I. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants. J Oral Rehabil 2006;33:754-9.   DOI   ScienceOn
12 Kahraman S, Bal BT, Asar NV, Turkyilmaz I, Tozum TF. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. J Oral Rehabil 2009;36:755-61.   DOI   ScienceOn
13 Dos Santos MV, Elias CN, Cavalcanti Lima JH. The effects of superficial roughness and design on the primary stability of dental implants. Clin Implant Dent Relat Res 2011; 13:215-23.   DOI   ScienceOn
14 Roze J, Babu S, Saffarzadeh A, Gayet-Delacroix M, Hoornaert A, Layrolle P. Correlating implant stability to bone structure. Clin Oral Implants Res 2009;20:1140-5.   DOI   ScienceOn
15 Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res 2002;13:65-74.   DOI   ScienceOn
16 Hong J, Lim YJ, Park SO. Quantitative biomechanical analysis of the influence of the cortical bone and implant length on primary stability. Clin Oral Implants Res 2012;23:1193-7.   DOI   ScienceOn
17 Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 2004;15:529-39.   DOI   ScienceOn
18 Trisi P, De Benedittis S, Perfetti G, Berardi D. Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: is there a relationship? An in vitro study. Clin Oral Implants Res 2011;22:567-70.   DOI   ScienceOn
19 Moon SH, Um HS, Lee JK, Chang BS, Lee MK. The effect of implant shape and bone preparation on primary stability. J Periodontal Implant Sci 2010;40:239-43.   DOI   ScienceOn
20 Hsu JT, Fuh LJ, Tu MG, Li YF, Chen KT, Huang HL. The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models. Clin Implant Dent Relat Res 2011 May 20 [Epub]. http://dx.doi.org/10.1111/j.1708-8208.2011.00349.x.
21 Merheb J, Van Assche N, Coucke W, Jacobs R, Naert I, Quirynen M. Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability. Clin Oral Implants Res 2010;21:612-7.   DOI   ScienceOn
22 Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res 2001;12:423-32.   DOI   ScienceOn
23 Khayat PG, Arnal HM, Tourbah BI, Sennerby L. Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm). Clin Implant Dent Relat Res 2011 May 20 [Epub]. http://dx.doi.org/10.1111/j.1708-8208.2011.00351.x.
24 Molly L. Bone density and primary stability in implant therapy. Clin Oral Implants Res 2006;17 Suppl 2:124-35.
25 Sim CP, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants Res 2010;21:598-604.   DOI   ScienceOn
26 Katsoulis J, Avrampou M, Spycher C, Stipic M, Enkling N, Mericske-Stern R. Comparison of implant stability by means of resonance frequency analysis for flapless and conventionally inserted implants. Clin Implant Dent Relat Res 2012;14:915-23.   DOI   ScienceOn
27 Ostman PO, Hellman M, Sennerby L. Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion. Clin Implant Dent Relat Res 2005;7 Suppl 1:S60-9.   DOI