A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy  

Kim, Young-Sung (Department of Periodontics, Asan Medical Center)
Kim, Soo-Hwan (Department of Periodontics, Asan Medical Center)
Kim, Won-Kyung (Department of Periodontics, Asan Medical Center)
Lee, Young-Kyoo (Department of Periodontics, Asan Medical Center)
Publication Information
Journal of Periodontal and Implant Science / v.39, no.4, 2009 , pp. 385-390 More about this Journal
Abstract
Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.
Keywords
dental equipment; gold alloys; ultrasonic;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Socransky SS, Haffajee AD. Dental biofilms: difficult therapeutic targets. Periodontol 2000 2002;28:12-55   DOI   ScienceOn
2 Kerry GJ. Roughness of root surfaces after use of ultrasonic instruments and hand curettes. J Periodontol 1967;38:340-346   DOI   PUBMED
3 Flemmig TF, Petersilka GJ, Mehl A, Hickel R and Klaiber B. The effect of working parameters on root substance removal using a piezoelectric ultrasonic scaler in vitro. J Clin Periodontol 1998;25:158-163.   DOI   ScienceOn
4 Ruppert M, Cadosch J, Guindy J, Case D, Zappa U. In vivo ultrasonic debridement forces in bicuspids: A pilot study. J Periodontol 2002;73:418-422   DOI   ScienceOn
5 Lee YK. Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study. J Korean Acad Periodontol 1998;28:823-828   DOI
6 Gellin RG, Miller MC, Javed T, Engler WO, Mishkin DJ. The effectiveness of the Titan-S sonic scaler versus curettes in the removal of subgingival calculus: a human surgical evaluation. J Periodontol 1986;57:672-680   DOI   PUBMED
7 Drisko CH. Root instrumentation: power-driven versus manual scalers, which one? Dent Clin North Am 1998;42:229-244   PUBMED
8 Wilkinson RF and Maybury JE. Scanning electron microscopy of the root surface following instrumentation. J Periodontol 1973;44:559-563   DOI   PUBMED
9 Zappa U, Cadosch J, Simona C, Graf H, Case D. In vivo scaling and root planing forces. J Periodontol 1991;62:335-340   DOI   PUBMED
10 Cha KB, Kim WK, Lee YK, Kim YS. The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro. J Korean Acad Periodontol 2009;39:139-148.   DOI   ScienceOn
11 Breininger DR, O'Leary TJ, Blumenshine RV. Comparative effectiveness of ultrasonic and hand scaling for the removal of subgingival plaque and calculus. J Periodontol 1987;58:9-18   DOI   PUBMED
12 Lee YK. The effect of a piezoelectric ultrasonic scaler with curette tip on casting gold removal in vitro. J Korean Acad Periodontol 2001;31:531-542   DOI
13 Zappa U, Smith B, Simona C, et al. Root substance removal by scaling and root planning. J Periodontol 1991;62:750-754.   DOI   PUBMED
14 Lee YK. The effect of a piezoelectric ultrasonic scaler with curette tip on root substitute removal in Vitro. J Korean Acad Periodontol 2000;30:429- 441   DOI