Browse > Article

Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems  

Oh, Jun-Ho (Department of Periodontology, School of Dentistry, Chonbuk National University)
Chang, Moon-Taek (Department of Periodontology, School of Dentistry, Chonbuk National University)
Publication Information
Journal of Periodontal and Implant Science / v.38, no.3, 2008 , pp. 529-534 More about this Journal
Abstract
Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.
Keywords
Resonance Frequency Analysis; dental implant; implant stability; initial healing;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Szmucler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Consideration preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12-25   DOI   ScienceOn
2 Adell, R., Lekholm, Ul, Rockler, B. & Branemark, PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. International Journal of Oral Surgery 1981;10:387-416   DOI
3 Friberg, B., Sennerby, L., Lin den, B., Grondahl, K. & Lekholm, U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. International Journal of Oral & Maxillofacial Surgery 1999a;28:266-272   DOI   ScienceOn
4 Albreksson, T.& Jacobsson, M. Bone-metal interface in osseointegration. Journal of Prosthetic Dentistry 1987;57: 597-607   DOI   ScienceOn
5 Caulier, H., Naert, I., Kalk, W. & Jansen , J.A The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: an experimental animal study. International journal of oral and maxillofacial implants 1997;3:380-386
6 Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-267   DOI   ScienceOn
7 Glauser R, Sennerby L, Meredith N, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004;15:428-434   DOI   ScienceOn
8 Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8: 226-233   DOI   ScienceOn
9 Roberts W. Bone tissue interface. J Dent Educ 1988;52(12): 804-809   PUBMED
10 Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants. Clin Oral Implants Res 2003;15:520-528   DOI   ScienceOn
11 Zix J, Kessler-Liechti G, Mericske-stern R. Stability measurements of 1-staged implants in the maxilla by means resonance frequency analysis: A pilot study. Int J Oral Maxillofac Implants 2005;20:747-752
12 Cochran KL, Schenk R, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res 1988;40:1-11
13 Davies JE. Mechanism of endosseous integration. Int J Prosthodont 1998;11:391-401   PUBMED
14 Derhami, Kl, Wolfaardt, J.F., Faulkner, G. & Grace M. Assessment of the periotest device in baseline mobility measurements of craniofacial implants. International journal of oral and maxillofacial implants 1995;10:221-229
15 Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003;18:641-651
16 Valderrama P, Oates TW, Jones AA, et al. Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial. J periodontol 2007;78:262-272   DOI   ScienceOn
17 Buser D, Schenk R, Steinemann S, et al. Influence of surface characteristics on bone integration of titanium implants. A histometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902   DOI
18 Branemark PI, Hanson BO, Adell R. osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconst Surg 1977;11 (Suppl 16):1-32   DOI
19 Cochran DL, Buser D, tenBruggenkate C, et al. The use of reduced healing times on ITI implants with a sandblasted and acid etched surface: Early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;13:144-153   DOI   ScienceOn
20 Olive, J. & Aparicio, C. Periotest method as a measure of osseointegrated oral implant stability. International Journal of Oral and Maxillofacial Implants 1990;5:390-400
21 Romeo E, Chiapasco M, Lazza A, et al. Implant-retained mandibular overdentures with ITI implants. Clin Oral Implants Res 2002;13:495-501   DOI   ScienceOn
22 OʼSullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004;15:474-480   DOI   ScienceOn
23 Huwiler MA, Pjetursson BE, Bosshardt DD, Salvi GE, Lang NP. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin Oral Implants Res 2007;18:275-280   DOI   ScienceOn
24 Albrektsson, T. & Isidor, F. Consensus report of session V. IN Lang, N-P. & Karring, T., des. Proceedings of the 1st European workshop on periodontology. London: Quintessence Publ. Co. 1994;365-369
25 Sunden S, Grondahl K, Grondahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Branemark dental implants. Clin Oral Implants Res 1995;6: 220-226   DOI   ScienceOn
26 Degidi M, Piattelli A. Immediate functional and non functional loading of dental implants: a 2- to 60- month follow-up study of 646 titanium implants. J Periodontol 2003;74:225-241   DOI   ScienceOn
27 Carlsson, L., Rostlund, T., Albrektsson, B. & Albrektsson, T. Removal torques for polished and rough titanium implants. International journal of Oral and Maxillofacial Implants 1988;3:21-24
28 Meredith, N. Assessment of implant stability as a prognostic determinant. International Journal of Prosthodontics 1998;11:491-501   PUBMED
29 Ersanli S, Karabuda C, Leblebicioglu B. Resonance frequency analysis one-stage dental implant stability during the osseointegration period. J Periodontol 2005;76;1066-1071   DOI   ScienceOn
30 OʼSullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Oral Implants Res 2000;2:85-92