Browse > Article

A compare research of machined implant and RBM surface implant  

Yoo, Im-Soo (Department of Periodontology, School of Dentistry, Dan Kook University)
Yim, Sung-Bin (Department of Periodontology, School of Dentistry, Dan Kook University)
Chung, Chin-Hyung (Department of Periodontology, School of Dentistry, Dan Kook University)
Hong, Ki-Seok (Department of Periodontology, School of Dentistry, Dan Kook University)
Publication Information
Journal of Periodontal and Implant Science / v.38, no.3, 2008 , pp. 467-474 More about this Journal
Abstract
Purpose: To evaluate RBM surface implant which has its good character like that good initial stability, early bone formation. Material and Methods: In this study fixures have divided in 2 group: Machined(Group I), RBM(Group II). Total 10 fixtures were implanted on rabbit which sacrificed on week 2 and week 4 for the histological specimens. By these specimens polarized microscopic view, micro CT view, ISQ value were measured, compared and analysed by each group to figure out the evidence that clinical use of RBM implant. Result: ISQ value had no significance differences between 2 groups, However in each group 4, 8 weeks had higher ISQ value than 2 weeks. In polarized microscope, calcification level was following: Group II, Group I. In micro CT, formation of cancellous bone level was following: Group II, Group I. Conclusion: RBM implant was the most excellent on the early bone formation and good initial stability.
Keywords
RBM; ISQ; Machined;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Buser D, Mericsek Stern R, Bernard JP et al. Long-term evaluation of non-submerged ITI implants. Part 1 : 8-year life table analysis of a prospctive multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-172   DOI   ScienceOn
2 Grook K, Geesink R, Klein C, Serekian P. Plasma sprayed coating of hydroxyapatite. Journal of Biomedical Materials Research 1987;21:1375-1381   DOI   ScienceOn
3 Da Cunha HA, Francischone CE, Filho DE, Oliveira RCG. A comparison between cutting torque and resonance frequency in the assessment of primary stability final torque capacity of standard and TiUnite single tooth implants under immediate loading. Int J Oral Maxillofac Implants 2004;19:578-585
4 Sennerby L, Meredith N. Resonance frequency analysis: Measuring implant stability and osseointegration. Compend Contin Educ Dent 1998;18:493-502
5 Steigenga JT, Al-Shammari K, Nociti FH, Misch CE, Want HL. Dental implant design and its relationship to long-term implant success. Implant Dent 2003;12:306-317   DOI   ScienceOn
6 Trico J, van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: an in vitro study. J Prosthet Dent 1995;74:608-612   DOI   ScienceOn
7 Schwarz MS, Rothman SLG, Rhodes ML, Chafetz N. Computed tomography: Part II. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants 1987;2:137-141   PUBMED
8 Fanuscu MI, Chang TL. Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible. Clin Oral Implants Res 2004;15: 213-218   DOI
9 Homolka P, Beer A, Birkfellner W et al. Local calibrated bone mineral density in the mandible presented using a color coding scheme. Med Eng Phys 2001;23:673   DOI   ScienceOn
10 Zix J, Kessler-Liechti G, Merickse-Stern R. Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Implants 2005;20:747-752
11 Branemark PI, Hansson BO, Adell R et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Almquist and Wiksell International 1977
12 Tolman DE, Laney WR. Tissue-integrated prothesis complications. Int J Oral Maxillofac Implants 1992;7:477-484   PUBMED
13 Hanazawa T, Sano T, Seki K, Okano T. Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images. Clin Oral Implants Res 2004;15:226-232   DOI   ScienceOn
14 Schwarz MS, Rothman SLG, Rhodes ML, Chafetz N. Computed tomography: PartI. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants. 1987;2:137-141   PUBMED
15 Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2004;19:578-585   PUBMED
16 Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-267   DOI   ScienceOn
17 Becker W, Sennerby L, Bedrossian E, Becker BE, Lucchini JP. Implant stability measurements for implant placed at the time of extraction: a cohort, prospective clinical study. J Periodontal 2005;76:391-397   DOI   ScienceOn
18 Eliades T. Passive film growth on titanium alloys: Physico-chemical and biological consideration. Int J Oral Maxillofac Implants 1997;12:621-627   PUBMED
19 Balshi TJ. An analysis and management of fractured implants: A clinical report. Int J Oral Maxillofac Implants 1996;11:660-666
20 Faulkner MG, Giannitsios D, Liipsett AW, Wolfarrdt JF. The use and abuse of the periotest for 2-piece implant/abutment systems. Int J Oral Maxillofac Implants 2001;16:486-494
21 Pan J, Thierry D, Leygraf C. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application. Elcetrochim Acta 1996;41:1143-1153   DOI   ScienceOn
22 Buser D, Schenk R, Steinemann S et al. Influence of surface characteristics on bone integration of titanium implants. A histomorpho-metric study in miniature pigs. Journal of Biomedical Materials Research 1991;25:889-902   DOI
23 Branemark PI, Hansson BO, Adell R et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977;111(Suppl 16):1-132
24 Rasmusson L, Stegersjo G, Kahnberg K-E, Sennerby L. Implant stability measurements using resonance frequency analysis in the grafted maxilla: a cross-sectional pilot study. Clin Oral Dent Relat Res 1999;1:70-74   DOI   ScienceOn
25 Levine RA, Clem DS, Wilson TG et al. Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for two or more years. Int J Oral Maxillofac Implants 1999;14:516-520
26 Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng 1998;26:275-391   DOI   PUBMED   ScienceOn
27 Wennerberg A, Albrektsson, Lausmaa J. Torque and histomorphometric and removal torque study of screw-shaped titanium implants and 75um sized particles of $Al_2O_3$. Journal of Biomedical Materials Research 1996;30:251-260   DOI
28 Lekholm U, Van Steenberghe D, Herrmann I et al. Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5year muticenter study. Int J Oral Maxillofac Implants 1994;9:627-635
29 Ragnar A, Eriksson B, Lekholm U et al. A long-term follow up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;14:210-216
30 Rasmussen L, Meredith N, Sennerby L. Measurements of stability changes of titanium implants with exposed threads subject to barrier membrane induced bone augmentation. An experimental study in the rabbit tibia. Clin Oral Implants Res 1997;8:316-322   DOI   ScienceOn
31 Homolka P, Beer A, Birkfellner W, Nowotny R et al. Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 2002;224:247-252   DOI   ScienceOn