1 |
Albrektsson, T., Zarb, G., Worthington, P, Eriksson, R.A. : The long-term efficacy of currently used dantal implants. A review and proposed criteria for success. Int J Oral Maxillofac Implants 1: 11-25, 1986
|
2 |
Esposito M, Hirsch JM, Lekhlm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci 106: 721-764, 1998
DOI
ScienceOn
|
3 |
Miyata T, Kobayashi Y, Araki H, Motomura Y, Shin K. The influence of controlled occlusal overload on periimplant tissue: A histologicstudy in monkeys. Int J Oral Maxillofac Implants 13: 677-683, 1998
|
4 |
Berglundh T, Lindhe J. Dimension of periimplant mucosa. Biological width revisited. J Clin Periodontol 23: 971-972, 1996
DOI
ScienceOn
|
5 |
Albrektsson, T., Branernark, P. -I., Hansson, H.A. & Lindstrm, J. Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone to implant anchorage in a man. Acta Orthopaedica Scandinavica 52: 155-170, 1981
DOI
PUBMED
|
6 |
Guo EX. Mechanical properties of cortical bone and cancellous bone tissue. In. Cowin SC, ed, Bone Mechanics Handbook Bpca Raton, FL: CRC Press 10: 1-23, 2001
|
7 |
Kemppainen P., Eskola S., Ylipaavalniemi P, A comparative prospective clinical study of two single-tooth implants: a preliminary report of 102 implants J Prosth Dent 77: 382-387, 1997
DOI
ScienceOn
|
8 |
Wyatt, C.C.L., Bryant, S.R., Avivi-Arber, L., Chaytor, D.V., Zarb, G.A. A computer-assisted measurement technique to assess bone proximal to oral implants on intraoral radiographs. Clin oral Impl Res 12: 225-229, 2001
DOI
ScienceOn
|
9 |
Wennstrom JL., Palmer RM. Survival and successrates with oral endosseous implants: Consensus report of Session C. In. Lang NP, Karring T, Lindhe J, eds, Proceedings of the 3rd European Workshop on Periodontology: Implant dentistry. Berlin: Quintessence Publishing Co.; 255-259, 1999
|
10 |
Palmer R., Palmer P., Smith B. A 5-year prospective study of Astra Single Tooth Implants Clin Oral Impl Res 11: 179-182, 2000
DOI
ScienceOn
|
11 |
Al Sayyed, A., Deporter, D.A., Pilliar, R.M., Waston. P.A., Pharoah, M., Berhane, K. & Carter, S. Predictable crestal bone remodelling around two porous-coated titanium alloy dental implant designs. Clin Oral Impl Res 5: 131-141, 1994
DOI
ScienceOn
|
12 |
Quirynen, M., Naert, I. & van Steenberghe, D. Fixture design and overload influence marginal bone loss and fixture success in the Branemark system. Clin Oral Implants Res 3: 104-111, 1992
DOI
ScienceOn
|
13 |
Batenburg, R.H.K., Meijer,H.J.A., Geraets, W.G.M. & van-der Stelt, P.F Radiographic assessment of changes in marginal bone around endosseous implants supporting mandibular overdendures, Dentomaxillofac Radiology 27: 221-224, 1998
DOI
ScienceOn
|
14 |
Misch CE, Bidez MW. A scientific rationale for dental implant design. In: Misch CE, ed. Contemporary Implant Dentistry, 2nd ed, St. Louis: Mosby, 329-343, 1999
|
15 |
Weber, H.P., Crohin, C.C., Fiorellini, J.P. A 5-year prospective clinical and radiographic study of non-submerged dental implants. Clin Oral Impl Res 11: 144-153, 2000
DOI
|
16 |
Isidor F. Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation. Clin Oral Implants Res 8: 1-9, 1997
DOI
ScienceOn
|
17 |
Cochran DL, Hermann JS, Schenk RK, Higginbottom FL, Buser D. Biologic width around titanium implants. A histometric analysis of the implanto- gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible. J Periodontol 68: 186-198, 1997
DOI
ScienceOn
|
18 |
Hermann JS, Buser D, Schenk RK, Cochran DL. Biologic width around titanium implants, A physiologically formed and stable dimension over time. Clin Oral Impl Res 11: 1-11, 2000
DOI
ScienceOn
|
19 |
Lekholm, U., van Steenberghe, D., Hermann, I., Bolender, C., Folmer, T., Gunne, J., Henny, P,. Higuchi, K., Laney, W.R., Linden, U. Osseointegrated implants in the treatment of partially edentulous jaws: a prospective 5-year multicenter study. Int J Oral Maxillofac Impl 9: 627-635, 1994
|
20 |
Wyatt, C.C.L., Zarb, G.A. Bone level changes proximal to oral implants supporting fixed partial prostheses. Clin Oral Impl Res 13: 162-168, 2002
DOI
ScienceOn
|
21 |
Norton M.R., Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure. Clin Oral Implants Res 9: 91-99, 1998
DOI
PUBMED
ScienceOn
|
22 |
Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res 12: 423-432, 2001
DOI
ScienceOn
|
23 |
Abrahamsson I, Berglundh T, Wennstrom J, Lindhe J. The peri-implant hard and soft tissue characteristics at different implant systems. A comparative study in dogs. Clin Oral Implant Res 7: 212-219, 1996
DOI
ScienceOn
|
24 |
Wilke, H.-J. Claes, L. & Steinemann, S. The influence of various titanium surfaces on the interface shear strength between implants and bone. In: Helmke, G., Soltesz, U. & Lee, A.J.C., eds, Clin, Oral Implants Materials. Advances in Biomaterials, Amsterdam: Elsevier Science Publishers B. V. 9: 309-314, 1990
|
25 |
Hanssen S. The implant neck: smooth or provided with retention elements. a biomechanical approach Clin Oral lmpl Res 10: 394-405, 1999
DOI
PUBMED
ScienceOn
|
26 |
Eriksson RA, Albrektsson T. The effect of heat on bone regeneration. J Oral Maxillofac Surg 42: 701-711, 1984
|
27 |
Miyata T, Kobayashi Y, Araki H, Shin K, Motomura Y. The influence of controlled occlusal overload on periimplant tissue. part 3: A histologic study in monkeys. Int J Oral Maxillofac Implants 15: 425-431, 2000
|