Abstract
This study was conducted to verify the effect of chlorine dioxide ($ClO_2$) on odor reduction at a commercial swine facility consisting of a compost ficility. Compost facility in $NH_3$ concentration was around 550 ppm and less than 78 ppm before and after the $ClO_2$ spraying, respectively, which was over 86% reduction. There was no H2S detection. $NH_3$ concentration was around 420 ppm and less than 35 ppm before and after the $ClO_2$ spraying, respectively, which was over 83% reduction. $H_2S$ concentration was around 210 ppb and less than 32 ppb before and after the $ClO_2$ spraying, respectively, which was over 85% reduction. Hence, $ClO_2$ spraying at windowless barns was compost facility decreased malodor such as $NH_3$.
Keywords
Compost facility; Gas; $ClO_2$; $NH_3$;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chastain, J. P. and F. J. Wolak. 2000. Application of a Gaussian Plume Model of Odor Dispersion to Select a Site for Livestock Facilities. Proceedings of the Odors and VOC Emissions 2000 Conference, sponsored by the Water Environment Federation, April 16-19, Cincinnati, OH., 14 pages, published on CD-ROM.
2 Donham, K. J. 1997. Human health and safety for workers in livestock housing. In: Latest developments in livestock housing. Proceedings of Commission Internationale du Genie Rural, Section 2 Seminar. 22-26.
3 Janni, K., Jacobson, L. D., Bicudo, J. R., Schmidt, D. and Guo, H. (2000). Livestock and poultry odor workshop II. biofilters, covers, OFFSET, and odor management plans. Dept. of Biosystems and Agricultural Engineering, University of Minnesota, St. Paul, MN. 100 pp.
4 MWPS. 1990. Mechanical ventilating systems for livestock housing, MWPS-32, Midwest Plan, Iowa State University, Ames.
5 Nicolai, R. E., C. J. Clanton, K. A. Janni. 2002. Ammonia Removal and Nitrogen Accumulation in Biofilter Media. In Proceedings of USC-TRG Conference on Biofiltration, 119-129. Newport Beach, California. October 31-November 1.
6 NIOSH (National Institute of Occupational Safety and Health). 2010. Centers for Disease Control and Prevention 1600 Clifton Rd. Atlanta, GA 30333, USA
7 Yuwono, A. and P. Schulze Lammers. 2004. Odor pollution in the environment and the detection instrumentation. Agricultural Engineering International: the CIGR Journal of Scientific Research and Development. Invited Overview Paper. Vol. VI.
8 류희욱, 조경숙, 이태호, 허 목. 2004. 양돈 시설 악취 관리 : III. 악취제어 기술. 한국냄새환경학회지. 3(1):1-11.
9 Bohn, H. L. 1996. "Biofilter Media", Air Waste Manage. Assoc., 89th Annual Meeting & Exhaubition, June 23-28, 96-WP 87A.01.
10 Chastain, J., "Odor control", Agr. Biolog. Eng., Clemson Univ. 1997.