A Study of Antibacterial Efficiency according to Direction of UV Irradiation in Cosmetic Case  

Jeong, Jae Young (Dept. of Biomedical Engineering, Gachon University)
Hwang, You Jin (Dept. of Biomedical Engineering, Gachon University)
Abstract
In this study, we propose an antibacterial efficiency according to the direction of UV irradiation. In the experiment, we measured the effective irradiation angle of UVC using S.aureus, a Gram-positive bacterium, and the variation of the antibacterial region according to the distance according to the direction of ultraviolet irradiation. Also, as a method to increase the antibacterial efficiency during horizontal irradiation of ultraviolet rays, we tested reflecting leaking UVC. As a result, the angle of ultraviolet irradiation was measured smaller than the product description, and in the case of the antibacterial area according to the direction of ultraviolet irradiation, the distance from the sample was increased during vertical irradiation, and the antibacterial area was increased as the distance from the sample was closer during horizontal irradiation. In addition, it was confirmed that antibacterial efficiency can be increased by reflecting leaking UVC during horizontal irradiation of UVC.
Keywords
UV; Vertical; Horizontal Irradiation; Antibacterial; Efficiency; Staphylococcus aureus;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 KS, "Measuring Methods of Ultraviolet Rays for Sterilization", https://e-ks.kr/streamdocs/view/sd;streamdocsId=72059199246666190
2 G. Kim, S. Kim, "A Study of Microbial Contamination in Cushion Foundation - Focused on the Sponge and puff -," Journal of the Korean Society of Cosmetology, Vol. 21, No. 6, pp. 1125-1130, 2015.
3 S. Kim, J. Cho, "Microbial Contamination of Lip Cosmetic", Journal of the Korean Society of Cosmetology, Vol. 14, No. 2, pp. 544-550, 2008.
4 S. Kim, D. Lim, "A Study of the Proper Use of Cosmetics and Microbial Contamination over Time," Journal of the Korean Society of Cosmetology, Vol. 15, No. 3, pp. 1059-1065, Aug. 2009.
5 T. Zollner, T. Wichelhaus, A. Hartung, C. Mallinckrodt, and T. Wagner, "Colonization with superantigen-producing Staphylococ cus aureus is associated with incresed severity of atopic dermatits," Clin. Exp. Allergy, Vol. 30, No. 7, pp. 994-1000, 2001. DOI : https://doi.org/10.1046/j.1365-2222.2000.00848.x   DOI
6 C. Bachert, P. Gevaert, and P. Cauwenberge, "Staphylococcus aureus enterotoxins: a key in airway disease," Allergy, Vol. 57, No. 6, pp. 480-487, Feb. 2002. DOI : https://doi.org/10.1034/j.1398-9995.2002.02156.x   DOI
7 M. Lee, M. Yoon, "The Status Microbial Contamination of Skin Care Tools", The Korean Society of Cosmetics and Cosmetology, Vol. 8, No. 3, pp. 467-477, Dec. 2018.
8 J. Song, E. Bae, "A Study on Analysis as a Case Study for the Cosmetic Container through the improvement Cosmetics Microorganism Pollution", Journal of the Korean Society Design Culture, Vol. 21, No. 4, pp. 297-307, Dec. 2015.
9 C. Mok, N. Lee, "Ultraviolet Inactivation, of Escherichia coli in Stainless Steel Cups," Food Engineering Progress, Vol. 13, No. 2, pp. 122-129, May. 2009.
10 J. Jee, W. Yang, E. Park, K. Kim and J. Joo, "Improvement of a UV/Ozone Duplex Sterilizer," Journal of The Korean Institute of Surface Engineering, Vol. 41, No. 2, pp. 76-82, Apr. 2008.   DOI
11 I. Lee, J. Park, S. Kim, J. Cha, K. Choi, and B. Lee, "Disinfection of Coliform Bacteria, Fungi and Pathogenic Bacteria by UV and Photocatalytic Effects", Korean Society Of Engineers, Vol. 23, No. 3, pp. 473-483, Feb. 2001.
12 S. Yum, I. Jung, J. Jeong and Y. Hwang, "A Study of Development Antibacterial Cosmetic Case using UV Wavelength", Journal of the Korea Society of Computer and Information, Vol. 25, No. 5, pp. 179-186, May. 2020. DOI : https://doi.org/10.9708/jksci.2020.25.05.179   DOI
13 H. B. Na and Y. J. Jang, "A Study on Development of Home Knife and Cutting Board Sterilizer Product Design Sterilization Function," Journal of Cultural Product & Design, Vol. 50, No. 0, pp. 165-178, 2017. DOI : http://dx.doi.org/10.18555/kicpd.2017.50.15   DOI
14 J. Han, C. Park, "Ultraviolet (UV) LED Industry and Market Trends", The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol. 33, No. 4, pp. 25-29, Jul. 2019.
15 Y. Yoo, "Cosmetic Case and Commercialization Factor Analysis", KISCI, pp. 1-63, 2013.
16 C. Na, A. Han, "Ultraviolet (UV) sterilization product safety survey", KCA, pp. 1-37, 2020.
17 S. Cha, D. Park, T. Choi, S. Cheon and G. Kil, "Optimum Layout of UV Light Source for Disinfection Efficacy Improvement", The Proceedings of the Korean Society of Marine Engineering, pp. 399-400, Oct. 2010.
18 K. Jung, D. Park, G. Kil, S. Cheon and W. Kim, "UV-LED Driving Method for Disinfection Efficacy Improvement", The Proceedings of the Korean Society of Marine Engineering, pp. 405-406, Oct. 2010.