A proposal of soft tissue landmarks for craniofacial analysis using three-dimensional laser scan imaging  

Baik, Hyoung-Seon (Department of Orthodontics, College of Dentistry, Yonsei University)
Lee, Hwa-Jin (Department of Orthodontics, College of Dentistry, Yonsei University)
Jeon, Jai-Min (Department of Orthodontics, College of Dentistry, Yonsei University)
Publication Information
The korean journal of orthodontics / v.36, no.1, 2006 , pp. 1-13 More about this Journal
Abstract
Three-dimensional (3-D) laser scans can provide a 3-D image of the face and it is efficient in examining specific structures of the craniofacial soft tissues. Due to the increasing concerns with the soft tissues and expansion of the treatment range, a need for 3-D soft tissue analysis has become urgent. Therefore, the purpose of this study was to evaluate the scanning error of the Vivid 900 (Minolta, Tokyo, Japan) 3-D laser scanner and Rapidform program (Inus Technology Inc., Seoul, Korea) and to evaluate the mean error and the magnification percentage of the image obtained from 3-D laser scans. In addition, soft tissue landmarks that are easy to designate and reproduce in 3-D images of normal, Class II and Class III malocclusion patients were obtained. The conclusions are as follows; scanning errors of the Vivid 900 3-D laser scanner using a manikin were 0.16 mm in the X axis, 0.15 mm in the Y axis, and 0.15 mm in the Z axis. In the comparison of actual measurements from the manikin and the 3-D image obtained from the Rapidform program, the mean error was 0.37 mm and the magnification was 0.66%. Except for the right soft tissue gonion from the 3-D image, errors of all soft tissue landmarks were within 2.0 mm. Glabella, soft tissue nasion, endocanthion, exocanthion, pronasale, subnasale, nasal alare, upper lip point, cheilion, lower lip point, soft tissue B point, soft tissue pogonion, soft tissue menton and preaurale had especially small errors. Therefore, the Rapidform program can be considered a clinically efficient tool to produce and measure 3-D images. The soft tissue landmarks proposed above are mostly anatomically important points which are also easily reproducible. These landmarks can be beneficial in 3-D diagnosis and analysis.
Keywords
3-D laser scanner; Craniofacial soft tissue analysis; Soft tissue landmarks;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Baumrind S, Moffitt FH, Curry S. The geometry of three dimensional measurement from paired coplanar x-ray images. Am J Orthod 1983;84:313-22   DOI   ScienceOn
2 Kawai T, Natsume N, Shibata H, Yamamoto T. Three-dimensional analysis of facial morphology using moire stripes. Part I. Method. Int J Oral Maxillofac Surg 1990;19:356-8   DOI   ScienceOn
3 Kusnoto B, Evans CA. Reliability of a 3D surface laser scanner for orthodontic applications. Am J Orthod Dentofacial Orthop 2002;122:342-8   DOI   ScienceOn
4 Bush K, Antonyshyn O. Three dimensional facial anthropometry using a laser surface scanner: validation of the technique. Plast Reconstr Surg 1996;98:226-35   DOI   ScienceOn
5 장혜숙, 백형선. 3차원 CT 영상을 이용한 안면 분석을 위한 계측점 제안. 대치교정지 2002;32:313-25
6 Ferrario VF, Sforza C, Serrao G, Puletto S, Bignotto M, Tartaglia G. Comparison of soft tissue facial morphometry in children with Class I and Class II occlusion. Int J Adult Orthodon Orthognath Surg 1994;9;187-94
7 Bittner C, Pancherz H. Facial morphology and malocclusion. Am J Orthod Dentofacial Orthop 1990;97:308-15   DOI   ScienceOn
8 Genecov JS, Sinclair PM, Dechow PC. Development of the nose and soft tissue profile. Angle Orthod 1990;60:191-8
9 Ferrario VF, Serrao G, Ciusa V, Marini M, Sforza C. Cephalometric and in vivo measurrnent of maxillomandibular anteroposterior discrepancies: a preliminary regression study. Angle Orthod 2002:72: 579-84
10 Farkas LG. Examination. In: Farkas LG editor. Anthropometry of the head and face. 2nd ed. New York: Raven Press; 1994. p. 3-56
11 Ferrario VF, Sforza C, Serrao G, Miani A Jr. A computerized noninvasive method for the assessment of human facial volume. J Craniomaxillofac Surg 1995;23:280-6   DOI   ScienceOn
12 Aung SC, Ngim RC, Lee ST. Evaluation of the laser scanner as a surface measuring tool and its accuracy compared with direct facial anthropometric measurements. Br J Plast Surg 1995:48:551-8   DOI   ScienceOn
13 Soncul M, Bamber MA. The optical surface scan as an alternative to the cephalograph for soft tissue analysis for orthognathic surgery. Int J Adult Orthodon Orthognath Surg 1999;14:227-83
14 Ferrario VF, Sforza C, Poggio CE, Cova M, Tartaglia G. Preliminary evaluation of an electromagnetic three dimensional digitizer in facial anthropometry. Cleft Palate Craniofacial J 1998;35:9-15   DOI   ScienceOn
15 Soncul M, Bamber MA. The reproducibility of the head position for a laser scan using a novel morphometric analysis for orthognathic surgery. Int J Adult Orthodon Orthognathic Surg 2000;29:86-90
16 Grayson B, Cutting C, Bookstein FL, Kim H, McCarthy JG. The three dimensional cephalogram. theory, technique, and clinical application. Am J Orthod Dentofacial Orthop 1988:94:327-37   DOI   ScienceOn
17 Cox NH, Van der Linden FPGM. Facial harmony. Am J Orthod Dentofacial Orthop 1971:60:175-83   DOI
18 Ferrario VF, Sforza C, Poggio CE, Serrao G. Facial three dimensional morphometry. Am J Orthod Dentofacial Orthop 1996;109:86-93   DOI   ScienceOn
19 Ferrario VF, Sforza C, Schmitz JH, Serrao G, Miani A Jr. A three dimensional computerized mesh diagram analysis and its application in soft tissue facial morphometry. Am J Orthod Dentofacial Orthop 1998;114:404-13   DOI   ScienceOn
20 Ferrario VF, Sforza C, Poggio CE, Schmitz JH. Three dimensional facial morphometry and conventional cephalometries: a correlation study. Int J Adult Orthodon Orthognath Surg 1996;11:329-38
21 Ferrario VF, Sforza C, Schmitz JH, Santoro F. Three dimensional facial morphometric assessment of soft tissue changes after orthognathic surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999:88:549-56   DOI   ScienceOn