Browse > Article
http://dx.doi.org/10.9714/psac.2010.12.1.047

Analysis of Charging Characteristics of Linear Type Magnetic Flux Pump Depended on Traveling Speed of Magnetic Field  

Chung, Yoon-Do (수원대학교 전기공학과)
Kim, Hyun-Ki (수원대학교 전기공학과)
Bae, Duck-Kweon (국립 충주대학교 안전공학과)
Yoon, Yong-Soo (안산공과대학 전기과)
Jo, Hyun-Chul (연세대학교 전기전자공학과)
Ko, Tae-Kuk (연세대학교 전기전자공학과)
Publication Information
Progress in Superconductivity and Cryogenics / v.12, no.1, 2010 , pp. 47-51 More about this Journal
Abstract
We already obtained magnetic behavior of superconducting Nb foil of linear type magnetic flux pump (LTMFP) by means of the FEM analysis. As well as, fundamental equations of pumping current were theoretically derived based on the pumping sequences according to the position of normal spot of the moving flux. In this paper, we experimentally investigated pumping performances of LTMFP with a wide range of traveling speed of magnetic field. In order to confirm the numerical and theoretical approaches, we explained the pumping characteristics of LTMFP by use of the calculation sequence of pumping current.
Keywords
linear type magnetic flux pump; superconductor; pumping current; traveling speed of magnetic field;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 T. Kiyoshi, A. Sato, H. Wada, S. Hayashi, M. Shimada and Y. Kawate, "Development of 1 GHz superconducting NMR magnet at TML/NRIM." IEEE Transactions on Applied Superconductivity, vol. 9, no. 2, pp. 559-562, 1999.   DOI   ScienceOn
2 정윤도, 배덕권, 윤용수, 고태국, "침투자속의 위치와 이동속도에 따른 리니어형 자속펌프 충전전류의 이론적 해석," 한국초전도 저온공학회논문지, vol. 11, no. 1, pp. 39-44, 2009.
3 Martin W. Wilson, "Superconducting Magnet," Clarendon Press-Oxford, 1983.
4 Y.D Chung, I. Muta, T. Hoshino, T. Nakamura and M.H. Sohn, "Design and performance of compensator for decremental persistent current in HTS magnets using linear type mangetic flux pump," Cryogenics, vol. 44, no. 11, pp. 839-844, 2004.   DOI   ScienceOn
5 P. Penczynski, H. Hentzelt and G. Eger, "Measurement of the temperature dependence of the 50 Hz alternating current losses of superconducting stabilized niobium conductors," Cryogenics, vol.14, pp. 503-509, 1974.   DOI   ScienceOn
6 Y.D. Chung, T. Hoshino, T. Nakamura, "Current pumping performance of linear type magnetic flux pump with use of feedback control circuit system," IEEE Transacions on Applied Superconductivity, vol. 16, no. 2, pp. 1638-1641, 2006.   DOI   ScienceOn
7 H. G. Lee, H.M. Kim and Y. Iwasa, "A flux pump for and NMR magnets," IEEE Transactions on Applied Superconductivity, Vol. 13, no. 2, pp. 1640-1643, 2003.   DOI   ScienceOn
8 이응로, 정윤도, 배덕권, 윤용수, 고태국, "시뮬레이션을 이용한 리니어형 자속 플럭스 펌프에서의 초전도 니오븀 박막의 자장분포 해석," 한국초전도 저온공학회논문지, vol. 11, no. 3, pp. 49-54, 2009.