1 |
Toumelin-Chemla F, Rouelle F, Burdairon G. Corrosive properties of fluoride-containing odontologic gels against titanium. J Dent 1996; 24:109-115.
DOI
ScienceOn
|
2 |
Hedenborg M. Titanium dioxide induced chemiluminescence of human polymorphonuclear leukocytes. Int Arch Occup Environ Health 1988; 61:1-6.
DOI
|
3 |
Javed F, Al-Hezaimi K, Almas K, Romanos GE. Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review. Clin Implant Dent Relat Res 2013;15:47-52.
DOI
ScienceOn
|
4 |
Wentz HJ, Bartsch J, Wolfart S, Kern M. Osseointegration and clinical success of zirconia dental implants: a systematic review. Int J Prosthodont 2001;21:27-36.
|
5 |
Ozkurt Z, Kazazoglu E. Zirconia dental implants:a literature review. J Oral Implantol 2011;37:367-376.
DOI
ScienceOn
|
6 |
Andreiotelli M, Wenz HJ, Kohal RJ. Are ceramic implants a viable alternative to titanium implants? A systematic literature review. Clin Oral Implants Res 2009;20(Suppl 4):32-47.
DOI
ScienceOn
|
7 |
Depprich R, Naujoks C, Ommerborn M, Schwarz F, Kübler NR, Handschel J. Current findings regarding zirconia implants. 2014;16:124-137.
DOI
ScienceOn
|
8 |
Manzano G, Herrero LR, Montero J. Comparison of clinical performance of zirconia implants and titanium implants in animal models: a systematic review. Int J Oral Maxillofac Implants 2014;29:311-320.
DOI
|
9 |
Kohal RJ, Att W, Bachle M, Butz F. Ceramic abutments and ceramic oral implants. An update. Periodontol 2000 2008;47:224-243.
DOI
ScienceOn
|
10 |
Lee J, Sieweke JH, Rodriguez NA, Schüpbach P, Lindström H, Susin C, Wikesjö UM. Evaluation of nano-technology-modified zirconia oral implants: a study in rabbits. J Clin Periodontol. 2009;36:610-7.
DOI
ScienceOn
|
11 |
Payer M, Heschl A, Koller M, Arnetzl G, Lorenzoni M, Jakse N. All-ceramic restoration of zirconia two-piece implants-a randomized controlled clinical trial. Clin Oral Implants Res 2014 Feb 6 [Epub ahead of print]
|
12 |
Irish JD. A 5,500 year old artificial human tooth from Egypt: a historical note. Int J Oral Maxillofac Implants. 2004;19:645-7.
|
13 |
Park YS, Jung MH, Shon WJ. Autotransplantion of a displaced mandibular second premolar to its normal position. Am J Orthod Dentofacial Orthop. 2013;143:274-80.
DOI
ScienceOn
|
14 |
Park YS, Baek SH, Lee WC, Kum KY, Shon WJ. Autotransplantation with simultaneous sinus floor elevation. J Endod. 2012;38:121-4.
DOI
ScienceOn
|
15 |
Pirker W, Kocher A. Immediate, non-submerged, root-analogue zirconia implants placed into singlerooted extraction sockets: 2-year follow-up of a clinical study. Int J Oral Maxillofac Surg 2009;38:1127-1132.
DOI
ScienceOn
|
16 |
Park YS, Chung SH, Shon WJ. Peri-implant bone formation and surface characteristics of rough surface zirconia implants manufactured by powder injection molding technique in rabbit tibiae. Clin Oral Implants Res 2013;24:586-91.
DOI
ScienceOn
|
17 |
Chung SH, Kim HK, Shon WJ, Park YS. Periimplant bone formations around (Ti,Zr)O(2) - coated zirconia implants with different surface roughness. J Clin Periodontol 2013;40:404-11.
DOI
ScienceOn
|
18 |
Shon WJ, Chung SH, Kim HK, Han GJ, Cho BH, Park YS. Peri-implant bone formation of nonthermal atmospheric pressure plasma-treated zirconia implants with different surface roughness in rabbit tibiae. Clin Oral Implants Res 2014;25:573-9.
|
19 |
Le Guehennec L, Soueidan A, Layrolle P, Amouriq Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater 2007;23:844-854.
DOI
ScienceOn
|
20 |
Steinemann SG. Titanium-the material of choice? Periodontol 2000 1998;17:7-21
|
21 |
Weingart DL, Steinemann S, Schilli W, Strub JR, Hellerich U, Assenmacher J, Simpson J. Titanium deposition in regional lymph nodes after insertion of titanium screw implants in maxillofacial region. Int J Oral Maxillofac Surg 1994;23:450-452.
DOI
ScienceOn
|
22 |
Sicilia A, Cuesta S, Coma G, Arregui I, Guisasola C, Ruiz E, Maestro A. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients. Clin Oral Implants Res. 2008 Aug;19(8):823-835.
|
23 |
Tschernitschek H, Borchers L, Geurtsen W. Nonalloyed titanium as a bioinert metal--a review. Quintessence Int 2005;36:523-530.
|
24 |
Gittens RA, Olivares-Navarrete R, Tannenbaum R, Boyan BD, Schwartz Z. Electrical implications of corrosion for osseointegration of titanium implants. J Dent Res 2011;90:1389-1397.
DOI
ScienceOn
|
25 |
Brüll F, van Winkelhoff AJ, Cune MS. Zirconia dental implants: a clinical, radiographic, and microbiologic evaluation up to 3 years. Int J Oral Maxillofac Implants 2014;29:914-20.
DOI
|
26 |
Ekelund JA, Lindquist LW, Carlsson GE, Jemt T. Implant tretment in the edentulous mandible: A prospective study on Br?nemark System implants over more than 20 years. Int J Prosthodont 2003;16:602-608.
|
27 |
van Brakel R, Noordmans HJ, Frenken J, de Roode R, de Wit GC, Cune MS, The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues. Clin Oral Implants Res 2011;22:1172-1178.
DOI
ScienceOn
|
28 |
Schliephake H, Neukam FW, Urban R. Titanbelastung parenchymatöser Organe nach Insertion von Titanschranubenimplantaten. Erste Ergebnisse. Z Zahnärztl Implnatol 1989;5:180-184.
|
29 |
Bianco PD, Ducheyne P, Cuckler JM. Local accumulation of titanium released from a titanium implant in the absence of wear. J Biomed Mater REs 1996;31:227-234.
DOI
ScienceOn
|
30 |
Reclaru L,Meyer JM. Study of corrosion between a titanium implant and dental alloys. J Dent 1994; 22:159-168.
DOI
ScienceOn
|