Browse > Article
http://dx.doi.org/10.4047/jap.2012.4.2.116

Implant overdenture using a locator bar system by drill and tapping technique in a mandible edentulous patient: a case report  

Kim, Min-Su (Department of Prosthodontics, School of Dentistry, Pusan National University)
Yoon, Mi-Jung (Department of Prosthodontics, School of Dentistry, Pusan National University)
Huh, Jung-Bo (Department of Prosthodontics, School of Dentistry, Pusan National University)
Jeon, Young-Chan (Department of Prosthodontics, School of Dentistry, Pusan National University)
Jeong, Chang-Mo (Department of Prosthodontics, School of Dentistry, Pusan National University)
Publication Information
The Journal of Advanced Prosthodontics / v.4, no.2, 2012 , pp. 116-120 More about this Journal
Abstract
Various options have been introduced for the selection of implant overdenture attachments. Attachment wear due to the repeated insertion and removal of dentures has caused problems such as decreased retention and the requirement for suprastructure remanufacturing. In these cases, a Locator bar system was applied using the drill and tapping technique to achieve total retrievability. In a 55-year-old female patient who showed three degrees of mobility in most of her teeth due to severe alveolar bone loss, a complete denture in the maxilla and an implant supported type overdenture in the mandible were planned after extracting all the remaining teeth. Six implants were placed from canine region to the distal molar region, and the locator was connected to the milled bar using the drill and tapping technique. For a 61-year-old female edentulous patient who complained of poor retention with old denture, a complete denture in the maxilla and an implant-tissue supported type overdenture in the mandible were planned. Four implants were placed in front of mental foramen, and the Locator was also connected to the Hader bar using the drill and tapping technique. With this technique, female parts can be easily replaced, and retention can be continuously maintained.
Keywords
Implant overdenture; Locator bar system; Drill & tapping technique; Total retrievability;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Sadowsky SJ. The implant-supported prosthesis for the edentulous arch: design considerations. J Prosthet Dent 1997;78:28-33.   DOI   ScienceOn
2 Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.   DOI
3 Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34.   DOI   ScienceOn
4 Kurtzman GM. Lab techniques for use of the locator attachment in bar-overdenture applications. TeamWork 2008;1:72-8.
5 Schneider AL, Kurtzman GM. Bar overdentures utilizing the Locator attachment. Gen Dent 2001;49:210-4.
6 Naert I, De Clercq M, Theuniers G, Schepers E. Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report. Int J Oral Maxillofac Implants 1988;3:191-6.
7 Celik G, Uludag B. Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures. J Prosthet Dent 2007;97:229-35.   DOI   ScienceOn
8 Pasciuta M, Grossmann Y, Finger IM. A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant-tissue-supported overdenture: a clinical report. J Prosthet Dent 2005;93:116-20.   DOI   ScienceOn
9 Lee CK, Agar JR. Surgical and prosthetic planning for a two-implant- retained mandibular overdenture: a clinical report. J Prosthet Dent 2006;95:102-5.   DOI   ScienceOn
10 Chung KH, Chung CY, Cagna DR, Cronin RJ Jr. Retention characteristics of attachment systems for implant overdentures. J Prosthodont 2004;13:221-6.   DOI   ScienceOn
11 DeBoer J. Edentulous implants: overdenture versus fixed. J Prosthet Dent 1993;69:386-90.   DOI   ScienceOn