Browse > Article
http://dx.doi.org/10.4047/jkap.2022.60.3.246

Maxillary complete denture rehabilitation in flabby tissue patient fabricated by no-pressure impression technique with individual tray replicated treatment denture through 3D printing: A case report  

Hong, Jun-Pyo (Department of Prosthodontics, Gachon University Gil Medical Center)
Bae, Jung-Yoon (Department of Prosthodontics, Gachon University Gil Medical Center)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.60, no.3, 2022 , pp. 246-253 More about this Journal
Abstract
Flabby tissue is not rare for denture wearers. Mucostatic impression technique is necessary due to compromised retention and stability of denture resulting from distortion of mobile flabby tissue. In this report, individual tray was fabricated by model-scanning and 3D printing treatment denture. And then, mucostatic impression for flabby tissue was obtained by using individual tray modified with window technique. Definitive denture was fabricated based on information of treatment denture including incisal pontic arrangement, jaw relationship and occlusion.
Keywords
3D printing individual tray; Complete denture; Flabby tissue;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Cutright DE. The histopathologic findings in 583 cases of epulis fissuratum. Oral Surg Oral Med Oral Pathol 1974;37:401-11.   DOI
2 Lynch CD, Allen PF. Management of the flabby ridge: using contemporary materials to solve an old problem. Br Dent J 2006;200:258-61.   DOI
3 Mai HN, Lee DH. A digital technique to replicate edentulous arches with functional borders and accurate maxillomandibular relationship for digital complete denture. J Prosthodont 2020;29:356-9.   DOI
4 Kihara H, Hatakeyama W, Komine F, Takafuji K, Takahashi T, Yokota J, Oriso K, Kondo H. Accuracy and practicality of intraoral scanner in dentistry: a literature review. J Prosthodont Res 2020;64:109-13.   DOI
5 Tolstunov L. Combination syndrome: classification and case report. J Oral Implantol 2007;33:139-51.   DOI
6 Crawford RW, Walmsley AD. A review of prosthodontic management of fibrous ridges. Br Dent J 2005;199:715-9.   DOI
7 Polyzois GL, Stavrakis GA, Demetriou PP. Dimensional accuracy of duplicate dentures prepared by different methods. J Prosthet Dent 1986;55:513-7.   DOI
8 McLaughlin JB, Ramos V Jr, Dickinson DP. Comparison of fit of dentures fabricated by traditional techniques versus CAD/CAM technology. J Prosthodont 2019;28:428-35.   DOI
9 Hong SJ, Lee H, Paek J, Pae A, Kim HS, Kwon KR, Noh K. Combining conventional impressions and intraoral scans: a technique for the treatment of complete denture patients with flabby tissue. J Prosthodont 2019;28:592-5.   DOI
10 Canger EM, Celenk P, Kayipmaz S. Denture-related hyperplasia: a clinical study of a Turkish population group. Braz Dent J 2009;20:243-8.   DOI